34-169-21802

Well Details

Well ID: 34-169-21802
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PETRO EVALUATION SERVICES INC
Well Pad ID:
Farm/Lease Name: BUCHHOLZ JOHN
License Status: Producing
License Date: 1974-06-14
Spud Date: 1975-02-03
Spud Drilling Contractor:
Final Drill Date: 1975-02-24
Well Total Depth: 3460.00 ft
Configuration: Vertical
Latitude: 40.820000
Longitude: -81.950000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1974-06-14 1062 YENNE A W GeoDate 6/14/74
Original Spud 1975-02-03 REVISED LOC. & COR LEASE NAME 10/23/1974
Completed 1975-02-24 REVISED LOC. & COR LEASE NAME 10/23/1974
Reached Total Depth 1975-02-24 REVISED LOC. & COR LEASE NAME 10/23/1974
Change of Owner 2018-07-18 Operator changed from 1062, A W YENNE TRUST NO 2 to 164, PETRO EVALUATION SERV INC
Record Last Modified 2018-07-18 REVISED LOC. & COR LEASE NAME 10/23/1974

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3298 3360 1
3298 3360 1
3298 3360 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 250 Gal 0 STYM TYPE MCA?
H2O 0 50000 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 A W YENNE TRUST NO 2 2196.00 0.00 365
2002 SANDY SUPPLY CO 2585.00 0.00 365
2003 SANDY SUPPLY CO 1221.00 0.00 365
2004 SANDY SUPPLY CO 2919.00 0.00 365
2005 SANDY SUPPLY CO 2369.00 0.00 365
2006 SANDY SUPPLY CO 2168.00 0.00 365
2007 A W YENNE TRUST NO 2 2070.00 0.00 365
2008 A W YENNE TRUST NO 2 1955.00 0.00 365
2009 A W YENNE TRUST NO 2 1890.00 0.00 365
2010 A W YENNE TRUST NO 2 1790.00 0.00 365
2011 SANDY SUPPLY CO 1925.00 0.00 365
2012 A W YENNE TRUST NO 2 1959.00 0.00 366
2013 A W YENNE TRUST NO 2 1612.00 0.00 365
2014 A W YENNE TRUST NO 2 2224.00 0.00 365
2015 A W YENNE TRUST NO 2 1832.00 0.00 365
2016 A W YENNE TRUST NO 2 1624.00 0.00 365
2017 A W YENNE TRUST NO 2 191.00 0.00 365
2018 A W YENNE TRUST NO 2 0.00 0.00 181

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 A W YENNE TRUST NO 2 Brine 0 365
2002 SANDY SUPPLY CO Brine 0 365
2003 SANDY SUPPLY CO Brine 0 365
2004 SANDY SUPPLY CO Brine 0 365
2005 SANDY SUPPLY CO Brine 0 365
2006 SANDY SUPPLY CO Brine 0 365
2007 A W YENNE TRUST NO 2 Brine 0 365
2008 A W YENNE TRUST NO 2 Brine 0 365
2009 A W YENNE TRUST NO 2 Brine 0 365
2010 A W YENNE TRUST NO 2 Brine 0 365
2011 SANDY SUPPLY CO Brine 0 365
2012 A W YENNE TRUST NO 2 Brine 0 366
2013 A W YENNE TRUST NO 2 Brine 0 365
2014 A W YENNE TRUST NO 2 Brine 0 365
2015 A W YENNE TRUST NO 2 Brine 0 365
2016 A W YENNE TRUST NO 2 Brine 0 365
2017 A W YENNE TRUST NO 2 Brine 0 365
2018 A W YENNE TRUST NO 2 Brine 0 181

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-557920800 2020-4-15 0:00: PW No Violations
-987196281 2014-12-15 0:00 PW No Violations 0.50
0747922401 2018-03-02 Production Wells No Violations Inspected production well on 03/02/2018. The tank battery consists of 1-50 bbl steel tank and 2-vertical separators, each located within separate locked metal fences; 1-meter with a drip and regulator is located nearby (outside of the fenced-in areas). The well is equipped with a flanged wellhead with 1-master valve, a swedge, elbow, and flowline, located within a locked metal fence with vinyl privacy inserts. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0987196281 2014-12-15 Production Wells No Violations This is a casing well that has apparent issues at time of inspection.
1119808105 2016-03-24 Production Wells No Violations Inspected production well on 03/24/2016. The well is equipped with a flanged wellhead with 2-master valves, a swedge, and flowline, all located within a locked metal fence. Well identification is clearly displayed. No problems were noted at the time of the inspection.
1285831871 2013-11-08 Production Wells No Violations Received complaint from Uniontown office. While in the process of swabing well, it unloaded oil onto ground. Complaint resolved. See complaint 4533 for details.
1295595652 2017-07-03 Production Wells No Violations Inspected production well on 07/03/2017. The tank battery consists of 1-50 bbl steel tank and 2-vertical separators, each located within separate locked metal fences. The well is equipped with a flanged wellhead with 2-master valves, a swedge, T, flowline, and pressure gauge, located within a locked metal fence. Well identification is clearly displayed at the wellhead. No problems were noted at the time of the inspection.
747922401 2018-3-2 0:00:0 PW No Violations

For data sources see[9]