X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-003-22186

Well Details

Well ID: 37-003-22186
Loading map...
Country: United States
State: Pennsylvania
County: Allegheny
Municipality: Plum Borough
Operator Name: PENNECO OIL CO INC
Well Pad ID:
Farm/Lease Name: CLAPPER 1
License Status:
Spud Date:
Permit Date: 2011-05-11
Well Type: OIL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.490336
Longitude: -79.711944

For data sources see[1][2][3]

Well History

Date Event
2011-05-11 New Permit Application
2011-05-26 Performed Spud Operation
2011-06-08 Drilling Completion
2011-06-15 Perforation
2012-01-23 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 PENNECO OIL CO INC 905.00 92 45.50 92 0.00 0
2012 PENNECO OIL CO INC 4,334.00 366 359.14 366 0.00 0
2013 PENNECO OIL CO INC 3,421.00 365 111.17 365 0.00 0
2014 PENNECO OIL CO INC 991.00 365 107.45 365 0.00 0
2015 PENNECO OIL CO INC 1,040.87 365 103.27 30 0.00 0
2016 PENNECO OIL CO INC 1,070.09 366 116.77 59 0.00 0
2017 PENNECO OIL CO INC 1,324.00 365 154.73 365 0.00 0
2018 PENNECO OIL CO INC 868.00 365 17.04 30 0.00 0
2019 PENNECO OIL CO INC 826.90 365 101.62 62 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 PENNECO OIL CO INC Fracing Fluid Waste 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 PENNECO OIL CO INC Drilling Fluid Waste 400.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 PENNECO OIL CO INC Produced Fluid 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 PENNECO OIL CO INC Drilling Fluid Waste 550.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2012 PENNECO OIL CO INC Produced Fluid 40.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2014 PENNECO OIL CO INC Produced Fluid 39 Bbl CENT WASTE TRT FAC NPDES PA0095443
2014 PENNECO OIL CO INC Produced Fluid 39.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2015 PENNECO OIL CO INC Produced Fluid 4 Bbl CENT WASTE TRT FAC NPDES PA0095443
2015 PENNECO OIL CO INC Produced Fluid 4.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2017 PENNECO OIL CO INC Produced Fluid 28.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1981594 Primary Facility 2011-06-02 Drilling/Alteration No Violations Noted CEMENT FLASHED WHILE CEMENTING 7".TOC INSIDE AT 470'.
1981606 Primary Facility 2011-05-27 Drilling/Alteration No Violations Noted WELL SPUDDED. NO ONE AT SITE.
1981609 Primary Facility 2011-06-01 Drilling/Alteration No Violations Noted SITE, PIT, ACCESS, AND E&S, OK.
1983167 Primary Facility 2011-06-06 Drilling/Alteration No Violations Noted CEMENT FLASHED CEMENTING 7".
1984634 Primary Facility 2011-06-01 Routine/Complete Inspection No Violations Noted On June 1st, 2011 I visited this site as a routine inspection. Drilling has started. The access road was in good condition. A Site ID and E&S plan were posted onsite. E&S controls were in place. The pit appeared to be in good condition and had adequate freeboard. Some dust was escaping. No accelerated erosion was observed at the time of inspection.
1985303 Primary Facility 2011-06-08 Routine/Complete Inspection No Violations Noted On June 8th, 2011 I visited this site as a routine inspection. Drilling was completed and the rig had moved off site. The access road was in good condition. A Site ID and E&S plan were posted onsite. E&S controls were in place. The pit appeared to be in good condition and had adequate freeboard. No accelerated erosion was observed at the time of inspection. The operator should continue to inspect the E&S controls routinely until site restoration is complete.
1991810 Primary Facility 2011-07-13 Drilling/Alteration No Violations Noted OIL AND GAS WELL IS COMPLETE. RESTORATION HAS BEGUN. ACCESS AND E&S ARE OK.
1991811 Primary Facility 2011-07-06 Drilling/Alteration No Violations Noted DRILLING COMPLETE AND WELL IS FRACED.
1992050 Primary Facility 2011-07-07 Routine/Complete Inspection No Violations Noted On July 7th, 2011 I visited this site as a routine inspection. Drilling was completed and the rig had moved off site. The access road was in good condition. A Site ID and E&S plan were posted onsite. E&S controls were in place. The pit was closed and filled. Site restoration had begun. No accelerated erosion was observed at the time of inspection. The operator should continue to inspect the E&S controls routinely until site restoration is complete.
1993495 Primary Facility 2011-07-28 Routine/Complete Inspection No Violations Noted On July 28th, 2011 I visited this site as a routine inspection. Drilling was completed and the rig had moved off site. The well was not yet in production. The access road was in good condition. A Site ID and E&S plan were posted onsite. E&S controls were in place. The pit was closed and filled. The site was graded, seeded, and mulched. Some growth was starting. No accelerated erosion was observed at the time of inspection. The operator should continue to inspect the E&S controls routinely until site restoration is complete.
1998344 Primary Facility 2011-07-28 Drilling/Alteration No Violations Noted THIS IS AN OIL AND GAS WELL. THE WELL IS COMPLETE AND THE RODS AND TUBING ARE IN.
2064156 Primary Facility 2012-04-11 Routine/Complete Inspection No Violations Noted THIS RECENTLY COMPLETED WELL IS EQUIPTED WITH A JACK AND DUMP SYSTEM.
2095904 Primary Facility 2012-08-06 Routine/Complete Inspection No Violations Noted WELL MAINTAINED OIL AND GAS WELL.
2468818 Primary Facility 2016-03-10 Routine/Complete Inspection No Violations Noted THIS OIL AND GAS WELL, IT'S JACK, AND PRODUCTION EQUIPTMENT HAVE BEEN WELL MAINTAINED.

THE SITE IS IN GOOD CONDITION.

For data sources see[7]

References