Well Details

Well ID: 37-003-22235
Loading map...
Country: United States
State: Pennsylvania
County: Allegheny
Municipality: Forward Township
Operator Name: EQT PROD CO
Well Pad ID: 148982
Farm/Lease Name: OLIVER EAST 590599
License Status:
Spud Date:
Permit Date: 2012-11-16
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.243464
Longitude: -79.904508

For data sources see[1][2][3]

Well History

Date Event
2012-11-16 New Permit Application
2013-02-05 Performed Spud Operation
2013-04-07 Drilling Completion
2013-07-01 Perforation
2014-08-29 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-07-01 2013-07-12 7,691 6,772,480 285,413

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 BA-40L Halliburton Buffer Potassium carbonate 584-08-7 60 0.00154 0
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00333 0
SP Breaker Halliburton Oxidizing Breaker Sodium Persulfate 7775-27-1 100 0.00003000 0
28% HCL Nabors Dissolves cement & minerals in perforations Hydrochloric Acid 7647-01-0 28 0.03826 0
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distillate 64742-47-8 30 0.02644 0
LP-65 Halliburton Scale Inhibitor Ammonium Chloride 12125-02-9 10 0.00244 0
Water Halliburton Carrier Water 7732-18-5 100 90.2138 0
WG-36 Halliburton Gelling Agent Guar Gum 9000-30-0 100 0.00132 0
HAI-OS Halliburton Protects casing Propargyl Alcohol 107-19-7 10 0.00005000 0
Methanol 67-56-1 60 0.00028 0
Sand Halliburton Proppant Crystalline Silica 14808-60-7 100 9.59786 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 EQT PROD CO 449,579.00 55 0.00 0 0.00 0
2014 EQT PROD CO 1,386,763.00 365 0.00 0 0.00 0
2015 EQT PROD CO 451,149.00 333 0.00 0 0.00 0
2016 EQT PROD CO 527,361.00 361 0.00 0 0.00 0
2017 EQT PROD CO 315,037.00 343 0.00 0 0.00 0
2018 EQT PROD CO 227,823.00 322 0.00 0 0.00 0
2019 EQT PROD CO 334,679.00 355 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 EQT PROD CO Produced Fluid 6,753.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2013 EQT PROD CO Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2013 EQT PROD CO Produced Fluid 240.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2014 EQT PROD CO Produced Fluid 285.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 EQT PROD CO Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014 EQT PROD CO Produced Fluid 3,731.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 1,276.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2014 EQT PROD CO Produced Fluid 441.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2014 EQT PROD CO Fracturing Fluid Waste 9.07 Tons LANDFILL 100419
2015 EQT PROD CO Produced Fluid 2,548.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Servicing Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 130.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Produced Fluid 1,998.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 880.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO 750.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 65.02 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 163.53 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 119.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 37.04 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 145.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 21.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2019 EQT PROD CO Other Oil & Gas Wastes 83.41 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 23.40 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2014-4
2019 EQT PROD CO Produced Fluid 7.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 449.23 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 128.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2130261 Primary Facility 2013-01-14 Routine/Complete Inspection No Violations Noted John Ley, Water Quality Specialist, SWRO was on site to conduct a pre-op inspection. The site sign was in place and showed the proper permitting information. The E&S controls and BMP's were in place and constructed according to plan. The pad was still under construction with ~ 75 % complete. The access road berms, soil stock pile and ~50% of the hillsides had been stabilized. There were no signs of excess erosion or sedimentation.
2134521 Primary Facility 2013-01-23 Drilling/Alteration No Violations Noted THE WELL IS SPUDDED AND THE CONDUCTOR IS IN. THE WELL IS COVERD.
2138963 Primary Facility 2013-02-11 Routine/Complete Inspection No Violations Noted John Ley, Water Quality Specialist, SWRO was on site to conduct a routine inspection. The site sign was in place and showed the proper permitting information. The E&S controls and BMP's were in place and constructed according to plan. The pad was completed. The access road berms, soil stock pile had been stabilized. There were no signs of excess erosion or sedimentation. The water impoundment was being constructed. This area will need to be stabilized once construction is completed. The well has 20” and 13 3/8’” casing set and cemented.
2146597 Primary Facility 2013-03-05 Drilling/Alteration No Violations Noted TOP HOLE RIG RAN 20" CASING THEN MOVED TO THE NEXT HOLE ON THE PAD.
2156528 Primary Facility 2013-04-01 Drilling/Alteration No Violations Noted DRILLING AT 5900'. THE SITE IS OK.
2156533 Primary Facility 2013-04-09 Drilling/Alteration No Violations Noted THE PRODUCTION CASING IS IN AND CEMENTED. THE SITE IS OK.
2169326 Primary Facility 2013-05-23 Drilling/Alteration No Violations Noted WELL IS DRILLED BUT NOT FRACED. LOGGING CREW IS SETTING UP. SITE IS OK.
2171246 Primary Facility 2013-05-03 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with ESX12-003-0008 EQT Oliver East Well Site Site 763587 (inspection record 2171160). Drilling activity for well #590596 (003-22237) was ongoing during time of inspection. No erosion or sedimentation issues were apparent. BMPs were installed according to plan and appeared adequate. Production fluids were contained and no leaks to the environment were evident.
2209247 Primary Facility 2013-08-15 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with ESX12-003-0008 EQT Oliver East Well Site Site 763587 (inspection record 22209242). No E&S issues were evident. BMPs were installed according to plan and appeared adequate. No leaks to the environment were noted.
2211313 Primary Facility 2013-10-02 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with ESX12-003-0008 EQT Oliver East Well Site (site number 763587, inspection record 2211285). Well tag needs updated. No E&S issues noted.
2220456 Primary Facility 2013-10-30 Drilling/Alteration No Violations Noted WELL IS NOT HOOKED UP. PIPELINE IS BEING RUN. PROTECTIVE COVER ON PARTS OF THE PAD.
2228794 Primary Facility 2013-10-08 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with ESX12-003-0008 EQT Oliver East Well Site (site number 763587, inspection record 2228779). Well tag was correct. No E&S issues noted.
2229115 Primary Facility 2013-11-01 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with ESX12-003-0008 EQT Oliver East Well Site (site number 763587, inspection record 2229112). No E&S issues noted.
2231281 Primary Facility 2013-12-11 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with ESX12-003-0008 EQT Oliver East Well Site (site number 763587, inspection record 2231278). Site was lightly snow covered at time of inspection. Water impoundment had necessary freeboard. Numerous Baker tanks were lined up along two sides of the pad. Well was properly labeled. No E&S issues noted. No leaks of residual waste or fluids to the environment were evident.
2243879 Primary Facility 2014-01-15 Routine/Complete Inspection No Violations Noted WELL IS PRODUCING. NEW STONE IS BEING PUT DOWN.
2283027 Primary Facility 2014-06-04 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with ESX12-003-0008 EQT Oliver East Well Site (site number 763587). Well was properly labeled and appeared equipped for production. No dust or E&S issues noted. No leaks of residual waste or fluids to the environment were evident.
2283073 Primary Facility 2014-06-25 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with ESX12-003-0008 EQT Oliver East Well Site (site number 763587). Inspection occurred after heavy rainfall. Water impoundment had necessary freeboard. Well was properly labeled. No E&S issues noted. No leaks of residual waste or fluids to the environment were evident.
2287642 Primary Facility 2014-07-09 Routine/Complete Inspection No Violations Noted THIS WELL IS COMPLETE AND HOOKED UP.
2310642 Primary Facility 2014-07-23 Routine/Complete Inspection No Violations Noted Site ID sign is correct. Drill rig was on site at time of inspection. Impoundment had necessary freeboard. No E&S or dust issues noted. No leaks of fluids noted.
2310673 Primary Facility 2014-08-08 Routine/Complete Inspection No Violations Noted Site ID sign was correct. Drill rig was on site at time of inspection. Dust suppression measures had been applied to access road. No E&S or dust issues noted. No apparent leaks of fluids.
2310700 Primary Facility 2014-09-18 Routine/Complete Inspection No Violations Noted Site ID sign was correct. Vegetative growth was good; site was well stabilized. No E&S or dust issues noted. No apparent leaks of production fluids. Well labels need updated.
2377463 Primary Facility 2015-06-02 Routine/Partial Inspection No Violations Noted On June 2, 2015, I inspected the Oliver East Pad as a routine partial inspection and made the following observations:
2433583 Primary Facility 2015-11-03 Routine/Complete Inspection No Violations Noted On 11/3/15, I performed a routine complete site inspection of the Oliver East site and made the following observations:
2448615 Primary Facility 2016-01-29 Routine/Complete Inspection No Violations Noted THIS WELL IS PROTECTED WITH CONCRETE BARRIERS AND IS HOOKED UP FOR PRODUCTION.

THE SITE IS IN GOOD CONDITION.

2481838 Primary Facility 2016-04-18 Routine/Complete Inspection No Violations Noted THIS GAS WELL AND IT'S PRODUCTION EQUIPTMENT HAVE BEEN WELL MAINTAINED.

THE SITE IS IN GOOD CONDITION.

2659352 Primary Facility 2017-11-07 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tag present. Well apparatus and brine tank appear to be in sound condition.
2753152 Primary Facility 2018-07-18 Routine/Complete Inspection No Violations Noted This well is in good condition. The pad is also clean and in good shape.
2797523 Primary Facility 2018-11-02 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tag present. Well apparatus and brine tanks and gas production units appear to be in sound condition. No accelerated erosion or sedimentation observed on well site or access road.

For data sources see[8]

References