X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-00610

Well Details

Well ID: 37-005-00610
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Plumcreek Township
Operator Name: EQT PROD CO
Well Pad ID:
Farm/Lease Name: F WALKER 1
License Status: Plugged and Abandoned
Spud Date: 1942-02-05
Permit Date:
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.686936
Longitude: -79.364446

For data sources see[1][2][3]

Well History

Date Event
1942-04-17 Drilling Completion
1942-12-30 Newly Drilled
2017-09-05 Begin Plugging
2017-09-18 Finished Plugging

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1986 APOLLO GAS CO 478.00 364 0.00 0 0.00 0
1987 APOLLO GAS CO 376.00 364 0.00 0 0.00 0
1988 APOLLO GAS CO 353.00 366 0.00 0 0.00 0
1989 APOLLO GAS CO 162.00 276 0.00 0 0.00 0
1991 APOLLO GAS CO 338.00 238 0.00 0 0.00 0
1997 CARNEGIE PROD CO 795 365 0.00 0 0.00 0
1998 CARNEGIE PROD CO 109 365 0.00 0 0.00 0
1999 CARNEGIE PROD CO 299 365 0.00 0 0.00 0
2000 EQUITRANS INC 215 365 0.00 0 0.00 0
2001 EQUITABLE PROD EASTERN STATES EXPLORATION INC 151 365 0.00 0 0.00 0
2003 EQT PROD CO 205 365 0.00 0 0.00 0
2004 EQT PROD CO 101 243 0.00 0 0.00 0
2005 EQT PROD CO 48 151 0 151 0.00 0
2006 EQT PROD CO 0.00 0 0.00 0 0.00 0
2007 EQT PROD CO 0.00 0 0.00 0 0.00 0
2008 EQT PROD CO 0.00 0 0.00 0 0.00 0
2009 EQT PROD CO 0.00 0 0.00 0 0.00 0
2010 EQT PROD CO 0.00 0 0.00 0 0.00 0
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 0.00 0 0.00 0 0.00 0
2013 EQT PROD CO 0.00 0 0.00 0 0.00 0
2014 EQT PROD CO 0.00 0 0.00 0 0.00 0
2015 EQT PROD CO 0.00 0 0.00 0 0.00 0
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2634894 Primary Facility 2017-09-12 Plugging(Includes Plugged/Mined Through) No Violations Noted 0 psi on two inch. Had. 6 5/8 inch had 20 psi opened to tank. No. Fluid to tank. Moved. 1'inch tubing out. Removed. 6 5/8 inch. Well head apart. Made 6. 5/8 inch to 4 1/2 inch. Converter.
2634896 Primary Facility 2017-09-12 Plugging(Includes Plugged/Mined Through) No Violations Noted Ran wireline to. 2350 feet. Cut 2 inch at 2348 feet. Set 175 sacks of class a cement from 2350 to 1387 feet Tripped tubing out.
2636287 Primary Facility 2017-09-15 Plugging(Includes Plugged/Mined Through) No Violations Noted No pressure on the well set 120 sack cement at from 1635 feet to 1066 feet tripped up to being waited on cement to set. Ran wireline cut 6 5/8 inch casing at 1018 feet cut at 1005 feet shot every hundred feet coming up the well. Came off at 896 feet. she currently pulled the 6 5/8 casing to 896 feet.
2637107 Primary Facility 2017-09-18 Plugging(Includes Plugged/Mined Through) No Violations Noted Eqt attempted to pull 8 inch. Exceeded pulling strength. Decided to perf every 100 feet. From packer to surface. Installed a 10 x 4 head to cement.

For data sources see[6]

References