37-005-30250

Well Details

Well ID: 37-005-30250
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Gilpin Township
Operator Name: MDS ENERGY DEV LLC
Well Pad ID: 146940
Farm/Lease Name: GILBERT C QUERIO 1A-43
License Status:
Spud Date:
Permit Date: 2009-02-11
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.680892
Longitude: -79.594746

For data sources see[1][2][3]

Well History

Date Event
2009-02-11 New Permit Application
2009-04-06 Performed Spud Operation
2009-04-09 Drilling Completion
2009-09-10 NEWLY DRILLED
2009-11-24 New Permit Application
2010-01-06 Drilling Completion
2010-08-30 Perforation
2011-12-23 DRILLED DEEPER

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 MDS ENERGY LTD 14,593.00 54 0.00 0 0.00 0
2011 MDS ENERGY LTD 53,346.00 317 0.00 0 0.00 0
2012 MDS ENERGY LTD 38,015.00 313 0.00 0 0.00 0
2013 MDS ENERGY LTD 32,784.00 364 0.00 0 0.00 0
2014 MDS ENERGY LTD 25,078.00 323 0.00 0 0.00 0
2015 MDS ENERGY DEV LLC 23,636.00 349 0.00 0 0.00 0
2016 MDS ENERGY DEV LLC 19,899.00 345 0.00 0 0.00 0
2017 MDS ENERGY DEV LLC 20,721.00 365 0.00 0 0.00 0
2018 MDS ENERGY DEV LLC 18,116.00 364 0.00 0 0.00 0
2019 MDS ENERGY DEV LLC 17,867.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 MDS ENERGY LTD Fracing Fluid Waste 1,350.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2010 MDS ENERGY LTD Fracing Fluid Waste 3,750.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 MDS ENERGY LTD Produced Fluid 430.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 MDS ENERGY LTD Fracing Fluid Waste 1,470.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 MDS ENERGY LTD Produced Fluid 114.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 MDS ENERGY LTD Produced Fluid 85.00 Bbl INJECTION DISPOSAL WELL 34-133-22523
2011 MDS ENERGY LTD Produced Fluid 84.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2013 MDS ENERGY LTD Produced Fluid 25.00 Bbl INJECTION DISPOSAL WELL 34-155-21438

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1853749 Primary Facility 2010-01-05 Routine/Complete Inspection No Violations Noted Drill rig located onsite and drilling was ongoing at the time of the inspection. Below grade pit located onsite and it had more than the required two feet of freeboard. Observed accelerated erosion & sedimentation with respect to the access road or well-site. The operator should continue to monitor the site during drilling and during well stimulation to insure that all erosion control measures continue to function properly until final restoration activities are completed.
1854274 Primary Facility 2009-12-30 Drilling/Alteration Violation(s) Noted No bldg. waiver, abandoned & Incorrect casg. & cement
1859090 Primary Facility 2010-01-26 Routine/Complete Inspection No Violations Noted Drilling had been completed at the time of the inspection. Well was not equipped for production. Below grade pit located onsite and in portions of the pit had only approximately 2 ½ feet of lined freeboard. Once the weather permits the operator should have all fluids removed from the pit. No accelerated erosion & sedimentation was observed with respect to the access road or well-site. The operator should continue to monitor the site and erosion controls until well development and final restoration activities are completed.
1901641 Primary Facility 2010-07-29 Routine/Complete Inspection No Violations Noted Drilling had been completed at the time of the inspection. Well was not equipped for production. Below grade pit located onsite and in portions of the pit had only approximately 2 ½ feet of lined freeboard. Site prep was underway for the well stimulation process. No accelerated erosion & sedimentation was observed in relation to the access road or well-site. Noted muddy tire tracks leaving the site that can be attributed to the landowner removing soil from the well-site for his own use.
1993346 Primary Facility 2011-08-04 Site Restoration No Violations Noted Drilling was completed on 01/06/10. Well appeared to be equipped for production. Brine tanks located onsite and appeared to be in sound condition. No accelerated erosion or sedimentation observed in relation to the access road or well-site.
2272806 Primary Facility 2014-05-22 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2511157 Primary Facility 2016-08-04 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2679051 Primary Facility 2018-01-08 Routine/Complete Inspection No Violations Noted At time of inspection, well drilled and appears equipped for production.
2780473 Primary Facility 2018-09-27 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and grounded 100 bbl fiberglass fluid collection tank look ok.
2836076 Primary Facility 2019-02-04 Routine/Complete Inspection No Violations Noted On 2/4/19 at 1414 hrs., I conducted a routine inspection of MDS Energy Development, LLC's Gilbert C Querio 1A-43 well (API 005-30250) in Gilpin Twp., Armstrong Co. The well pad is restored and permanently stabilized. The well is equipped for production. A site ID sign is present at the entrance to the well pad. A well tag is affixed to the well head. There are no violations noted for this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1854274 579096 12/30/2009 2009-12-30 205A - Drilling w/in 200 ft of building or water well w/o variance Administrative
1854274 579097 12/30/2009 2009-12-30 207B - Failure to case and cement to prevent migrations into fresh groundwater Environmental Health & Safety
1854274 579098 12/30/2009 2009-12-30 210UNPLUG - Failure to plug a well upon abandonment Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
579096 254052 NOV - Notice of Violation Comply/Closed 2010-02-24
579096 266585 CACP - Consent Assessment of Civil Penalty Comply/Closed 2011-01-06 2011-01-06 $26,000.00 $26,000.00
579097 254052 NOV - Notice of Violation Comply/Closed 2010-02-24
579097 266585 CACP - Consent Assessment of Civil Penalty Comply/Closed 2011-01-06 2011-01-06 $26,000.00 $26,000.00
579098 254052 NOV - Notice of Violation Comply/Closed 2010-02-24
579098 266585 CACP - Consent Assessment of Civil Penalty Comply/Closed 2011-01-06 2011-01-06 $26,000.00 $26,000.00

For data sources see[7]

References