Well Details

Well ID: 37-005-30676
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Boggs Township
Operator Name: SNYDER BROS INC
Well Pad ID: 146583
Farm/Lease Name: BVL/SHAWMUT 2M-100
License Status:
Spud Date:
Permit Date: 2010-06-29
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.888822
Longitude: -79.421797

For data sources see[1][2][3]

Well History

Date Event
2010-06-29 New Permit Application
2011-04-01 Performed Spud Operation
2011-04-08 Drilling Completion
2012-02-23 New Permit Application
2012-12-06 Drilling Completion
2013-08-23 Perforation
2014-04-14 DRILLED DEEPER
2014-05-06 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-08-27 2013-08-28 6,638 181,697 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Super 100 NE Nabors Completion and Production Services Surfactants & Foamers Methanol 67-56-1 15 0.0207 0
Glycol Ether 111-76-2 5 0.0069 0
N-Cocoamidopropyl-N,N-dimethyl-N-2-hydroxypropylsulfobetaine
68139-30-0 15 0.0207 0
Isopropyl Alcohol 67-63-0 40 0.0552 0
Super GREEN SOLV-M Nabors Completion and Production Services Paraffin & Scale Additives Tridecane Proprietary 9 0.00009500 0
tetradecane Proprietary 11 0.000116 0
Dodecane Proprietary 14 0.000147 0
Undecane Proprietary 8 0.00008400 0
Aliphatic Hydrocarbons Proprietary 95 0.000998 0
WFR-3B Nabors Completion and Production Services Friction Reducer Hydrotreated light distillates, non-aromatic, BTEX free 64742-47-8 30 0.033363 0
Ethoxylated oleylamine 26635-93-8 5 0.00556 0
Ethoxylated alcohols 68002-97-1 15 0.016681 0
Other Ingredients Nabors Completion and Production Services Other Ingredients Water 7732-18-5 48 0.000403 0
Water 7732-18-5 40 0.044484 0
Solvent Proprietary 1 0.00138 0
Monoethanolamine Proprietary 100 0.00138 0
Proprietary Proprietary 1 0.00138 0
Proprietary Proprietary 100 0.138001 0
Alkyl Phosphate Ether Proprietary 1 0.00138 0
Water 7732-18-5 50 0.069 0
Polymer Proprietary 10 0.0138 0
Anionic Polyacrylamide 910644-97-2 40 0.044484 0
Water 7732-18-5 87.5 0.129767 0
ammonium, (2-Hydroxyethyl)trimethyl-, chloride 67-48-1 80 0.00049 0
Water 7732-18-5 60 0.002845 0
Propylene glycol 57-55-6 15 0.016681 0
Proprietary Proprietary 2 0.002224 0
Water 7732-18-5 80 0.004125 0
Proprietary Proprietary 50 0.002371 0
Polymer Proprietary 1 0.00138 0
Dioxane 123-91-1 1 0.00000800 0
Ammonium salts Proprietary 100 0.0276 0
Proprietary Proprietary 15 0.000711 0
Phosphoric Acid 7664-38-2 100 0.00138 0
2-Butoxyethanol 111-76-2 13 0.000109 0
Demineralized Water 7732-18-5 50 0.000306 0
ICP-1000 Nabors Completion and Production Services Iron Control Additives Anionic Copolymer Proprietary 50 0.004936 0
Propylene glycol 57-55-6 50 0.004936 0
PA Specific 40/70 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Crystalline Silica, quartz 14808-60-7 99.9 10.9972 0
Aluminum Oxide 1344-28-1 1.1 0.12109 0
Iron Oxide 1309-37-1 0.1 0.011008 0
Titanium Oxide 13463-67-7 0.1 0.011008 0
Water SNYDER BROTHERS INC Water Water 7732-18-5 100 51.327 0
PA Specific 30/50 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Aluminum Oxide 1344-28-1 1.1 0.064792 0
Titanium Oxide 13463-67-7 0.1 0.00589 0
Iron Oxide 1309-37-1 0.1 0.00589 0
Crystalline Silica, quartz 14808-60-7 99.9 5.88434 0
HCl Acid (12.5%-18.0%) Nabors Completion and Production Services Bulk Acid Hydrogen Chloride 7647-01-0 18 0.026695 0
Nitrogen per MSCF Nabors Completion and Production Services Nitrogen Materials Nitrogen 7727-37-9 100 31.2089 0
Acid Inhibitor 2 (AI-2) Nabors Completion and Production Services Acid Corrosion Inhibitors Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 10 0.00008400 0
Isopropyl Alcohol 67-63-0 40 0.000336 0
Glycol Ethers 111-46-6 40 0.000336 0
Propargyl Alcohol 107-19-7 40 0.000336 0
Ethoxylated Nonylphenol 68412-54-4 13 0.000109 0
KR-153SL Nabors Completion and Production Services Biocides Polyethlyene-Glycol 25322-68-3 50 0.002578 0
2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.001031 0
HCL Acid (0%-7.5%) Nabors Completion and Production Services Bulk Acid Water 7732-18-5 92.5 0.134936 0
Hydrogen Chloride 7647-01-0 7.5 0.010941 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2011 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2012 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2013 SNYDER BROS INC 31,830.00 88 0.00 0 0.00 0
2014 SNYDER BROS INC 61,527.00 363 0.00 0 0.00 0
2015 SNYDER BROS INC 37,351.00 348 0.00 0 0.00 0
2016 SNYDER BROS INC 28,020.00 349 0.00 0 0.00 0
2017 SNYDER BROS INC 23,368.00 359 0.00 0 0.00 0
2018 SNYDER BROS INC 21,876.00 355 0.00 0 0.00 0
2019 SNYDER BROS INC 19,390.00 353 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SNYDER BROS INC Drill Cuttings 53.00 Tons ON SITE ENCAPSULATION
2013 SNYDER BROS INC Fracing Fluid Waste 1,710.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW006
2013 SNYDER BROS INC Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2013 SNYDER BROS INC Fracing Fluid Waste 370.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2013 SNYDER BROS INC Fracing Fluid Waste 695.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SNYDER BROS INC Fracing Fluid Waste 370.00 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2014 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 SNYDER BROS INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2016 SNYDER BROS INC Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2017 SNYDER BROS INC Produced Fluid 36.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2017 SNYDER BROS INC 36.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2018 SNYDER BROS INC Produced Fluid 60.00 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-099-23158

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1957413 Primary Facility 2011-03-15 Routine/Complete Inspection No Violations Noted Site constructed, drilling had not commenced. E&S plan had been implemented as outlined. The erosion controls, if maintained properly, should effectively minimize accelerated erosion & sedimentation.
1968046 Primary Facility 2011-04-25 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. Well was not equipped for production. Drill pit contained drill cuttings and fluids. Pit had more than the required two feet of lined freeboard. No accelerated erosion or sedimentation in relation to the access road or site.
2044960 Primary Facility 2012-02-23 Site Restoration No Violations Noted Well was not equipped for production. There was no observed accelerated erosion or sedimentation observed in relation to the access road or well-site.
2082456 Primary Facility 2012-07-11 Routine/Complete Inspection No Violations Noted Drilling was not ongoing at the time of the inspection. Drill pit had been regraded. There was no observed accelerated erosion or sedimentation in relation to the well or access road.
2119254 Primary Facility 2012-11-29 Routine/Complete Inspection No Violations Noted Well-site had been enlarged and a new drill pit had been excavated. Drill pit was properly lined and contained no fluids or solids at the time of the inspection. Site had been temporarily stabilized and the site erosion controls had been properly implemented.
2123907 Primary Facility 2012-11-12 Drilling/Alteration No Violations Noted Drilling complete
2131601 Primary Facility 2013-01-17 Routine/Complete Inspection No Violations Noted Drilling was completed on 12/05/12, well was not stimulated. Drill pit located onsite and it had more than the required two feet of lined freeboard. Access road and site erosion controls appeared to be functioning properly and there was no evidence of accelerated erosion or sedimenation observed. The Department recommends that the operator inspect site and access road controls after the most recent snowfall has melted or well stimulation activities are commenced, whichever is sooner.
2144755 Primary Facility 2013-03-04 Routine/Complete Inspection No Violations Noted Drilling was completed on 12/05/12, well was not stimulated. Drill pit located onsite and it had more than the required two feet of lined freeboard. Access road and site erosion controls appeared to be functioning properly and there was no evidence of accelerated erosion or sedimenation observed.
2168421 Primary Facility 2013-05-22 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it had more than the required two feet of lined freeboard. Access road and site erosion controls appeared to be functioning properly and there was no evidence of accelerated erosion or sedimenation observed.
2196954 Primary Facility 2013-08-12 Routine/Complete Inspection No Violations Noted Drilling was completed on 12/06/12, well was not stimulated. Drill pit located onsite and it had more than the required two feet of lined freeboard. Access road and site erosion controls appeared to be functioning properly and there was no evidence of accelerated erosion or sedimentation observed.
2243403 Primary Facility 2014-02-06 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. The site had been properly restored and there was no observed accelerated erosion or sedimentation.
2383148 Primary Facility 2015-06-29 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2748360 Primary Facility 2018-07-03 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and 2 grounded 100 bbl fiberglass fluid collection tanks look ok.