If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30720 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.722833,"lon":-79.421139,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Kittanning Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 149601 | |
Farm/Lease Name: WRIGHT 590660 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-10-13 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.722833 | |
Longitude: -79.421139 |
Date | Event |
---|---|
2010-10-13 | New Permit Application |
2011-08-18 | Performed Spud Operation |
2011-12-05 | Drilling Completion |
2012-02-03 | Perforation |
2012-10-26 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-03-01 | 2012-03-01 | 7,132 | 7,013,832 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | LP-65 | Halliburton Energy Services | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 0.00270000 | ||
Hydrochloric Acid | Halliburton Energy Services | 15 HCl Acid | ||||||
Hydrochloric Acid | Halliburton Energy Services | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 0.00010000 | |||
Methanol | 67-56-1 | 0.00040000 | ||||||
Hydrochloric acid | 7647-01-0 | 0.03 | ||||||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.02 | |||
BE-9 Biocide | Halliburton Energy Services | Biocide | Tri-n-butyl tetradecyl phosphonium chloride | 81741-28-8 | 0.00460000 | |||
GBW-30 BREAKER | Halliburton Energy Services | Enzyme Breaker | Hemicellulase enzyme | 9012-54-8 | 0.00 | |||
SP Breaker | Halliburton Energy Services | Oxidizing Breaker | Sodium persulfate | 7775-27-1 | 0.00020000 | |||
WG-36 GELLING AGENT | Halliburton Energy Services | Gelling Agent | Naphtha, petroleum, hydrotreated heavy | 64742-48-9 | 0.00 | |||
Guar gum | 9000-30-0 | 0.00560000 | ||||||
BA-40L | Halliburton Energy Services | Buffer | Carbonic acid, dipotassium salt | 584-08-7 | 0.00006000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EQT PROD CO | 639,842.00 | 238 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 473,009.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 386,064.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 379,556.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 293,552.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 246,672.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 227,715.00 | 359 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 180,911.00 | 354 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | EQT PROD CO | Drilling Fluid Waste | 990.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EQT PROD CO | Fracing Fluid Waste | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-053-20968 |
2011 | EQT PROD CO | Drilling Fluid Waste | 925.00 Bbl | INJECTION DISPOSAL WELL | 34-115-21896 |
2011 | EQT PROD CO | Fracing Fluid Waste | 130.00 Bbl | INJECTION DISPOSAL WELL | 34-009-21899 |
2011 | EQT PROD CO | Drilling Fluid Waste | 520.00 Bbl | INJECTION DISPOSAL WELL | 34-053-20968 |
2011 | EQT PROD CO | Fracing Fluid Waste | 460.00 Bbl | INJECTION DISPOSAL WELL | 34-115-21896 |
2011 | EQT PROD CO | Fracing Fluid Waste | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2011 | EQT PROD CO | Drilling Fluid Waste | 150.00 Bbl | LANDFILL | SWF 1025 |
2012 | EQT PROD CO | Produced Fluid | 327.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2012 | EQT PROD CO | Produced Fluid | 2.00 Bbl | INJECTION DISPOSAL WELL | 34-151-21198 |
2012 | EQT PROD CO | Drilling Fluid Waste | 50.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid | 771.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | EQT PROD CO | Produced Fluid | 1,169.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012 | EQT PROD CO | Produced Fluid | 493.00 Bbl | INJECTION DISPOSAL WELL | 34-167-29577 |
2012 | EQT PROD CO | Produced Fluid | 3,023.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2012 | EQT PROD CO | Produced Fluid | 829.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24137 |
2012 | EQT PROD CO | Produced Fluid | 8,296.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid | 415.00 Bbl | INJECTION DISPOSAL WELL | 34-133-22523 |
2012 | EQT PROD CO | Produced Fluid | 996.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2012 | EQT PROD CO | Fracing Fluid Waste | 140,454.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid | 543.00 Bbl | INJECTION DISPOSAL WELL | 34-167-28466 |
2013 | EQT PROD CO | Produced Fluid | 11,006.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 408.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2013 | EQT PROD CO | Produced Fluid | 240.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2013 | EQT PROD CO | Produced Fluid | 737.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | EQT PROD CO | Produced Fluid | 6,202.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid | 105.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2014 | EQT PROD CO | Produced Fluid | 712.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2014 | EQT PROD CO | Produced Fluid | 112.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2015 | EQT PROD CO | Produced Fluid | 275.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2015 | EQT PROD CO | Fracturing Fluid Waste | 79.30 Tons | LANDFILL | 101397 |
2015 | EQT PROD CO | Produced Fluid | 103.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | EQT PROD CO | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24076 |
2015 | EQT PROD CO | Produced Fluid | 101.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2015 | EQT PROD CO | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2015 | EQT PROD CO | Produced Fluid | 219.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | EQT PROD CO | Produced Fluid | 210.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2015 | EQT PROD CO | Produced Fluid | 6,295.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 130.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 962.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2016 | EQT PROD CO | Produced Fluid | 3,322.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 298.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | EQT PROD CO | Produced Fluid | 123.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2017 | EQT PROD CO | Produced Fluid | 1,231.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | 686.00 Bbl | REUSE (AT WELL PAD) | ||
2017 | EQT PROD CO | 220.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 | |
2017 | EQT PROD CO | Produced Fluid | 1,308.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | 1,004.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 44.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid | 327.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 403.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 1,103.37 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | EQT PROD CO | Produced Fluid | 68.94 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | EQT PROD CO | Produced Fluid | 67.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid | 448.32 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 29.21 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 26.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 697.12 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 104.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | EQT PROD CO | Produced Fluid | 25.56 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1999121 | Primary Facility | 2011-08-23 | Drilling/Alteration | No Violations Noted | 40' conductor |
1999124 | Primary Facility | 2011-08-25 | Drilling/Alteration | No Violations Noted | rigging up |
2002332 | Primary Facility | 2011-09-07 | Drilling/Alteration | Violation(s) Noted | No coal protective casing installed |
2002394 | Primary Facility | 2011-09-13 | Routine/Complete Inspection | No Violations Noted | Waiting for Kick off |
2009640 | Primary Facility | 2011-09-28 | Drilling/Alteration | No Violations Noted | Awaiting for rig to drill horizontal section |
2009735 | Primary Facility | 2011-10-04 | Drilling/Alteration | No Violations Noted | waiting to drill horizontal |
2012074 | Primary Facility | 2011-10-18 | Routine/Complete Inspection | No Violations Noted | @ KOP |
2022354 | Primary Facility | 2011-11-22 | Drilling/Alteration | No Violations Noted | Building curve at 6267' |
2023990 | Primary Facility | 2011-12-02 | Drilling/Alteration | No Violations Noted | TD @ 12401' |
2026246 | Primary Facility | 2011-12-08 | Routine/Complete Inspection | No Violations Noted | Drlg Complete; 5 1/2" installed |
2029392 | Primary Facility | 2011-12-21 | Routine/Complete Inspection | No Violations Noted | TD 12,400' |
2039445 | Primary Facility | 2012-02-02 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed. Flowback pit and well stimulation impoundment located onsite and both had more than the required two feet of lined freeboard. All erosion controls had been implemented and maintained as outlined in the E&S plan included as part of the ESCGP. |
2047085 | Primary Facility | 2012-03-01 | Routine/Complete Inspection | No Violations Noted | Id sign and e&s plan onsite. Trucks hauling water. Haliburton onsite for frac. |
2055368 | Primary Facility | 2012-03-30 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed. Flowback pit and well stimulation impoundment located onsite and both had more than the required two feet of lined freeboard. All erosion controls had been implemented and maintained as outlined in the E&S plan included as part of the ESCGP. |
2069631 | Primary Facility | 2012-05-18 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed well was not fully equipped for production. Frac flowback and reshwater impoundments located onsite. Both impoundments liners appeared to be in sound condition and there was more than the required two feet of lined freeboard. Site and access road erosion controls had been properly maintained and there was no observed accelerated erosion or sedimenation in relation to the site or access road. |
2098459 | Primary Facility | 2012-09-07 | Routine/Complete Inspection | No Violations Noted | |
2114026 | Primary Facility | 2012-10-25 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite within containment and they appeared to be in sound condition. Site was in the process of beginning final site restoration. There were approximately 40 roll-offs boxes sitting on the well pad. Currently the storage of the roll-off boxes containing sludge from the frac flowback pit and the liner from the frac-flowback pit are not on secondary containment. This does not meet the requirements that all hydraulic fracturing additives and flowback be on containment as outlined in the Oil & Gas Act 3218.2(c). On future well pads all roll-off boxes which contain frac flowback sludge and frac flowback impoundment liner should be stored on containment to minimize the possibility of a discharge of liquids from these tanks onto the ground. |
2164324 | Primary Facility | 2013-05-03 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed at the time of the inspection. Wells appeared to be equipped for production. Brine tanks located onsite within containment. Site had been regraded and the vegetation had begun to take hold. Contact with the operator confirmed that once the vegetation has achieved 70% uniform coverage the sediment traps would be removed and those areas regraded as well. |
2208908 | Primary Facility | 2013-10-01 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed at the time of the inspection. Wells appeared to be equipped for production. Brine tanks located onsite within containment. Site had been regraded and the vegetation had begun to take hold. Once the vegetation has achieved 70% uniform coverage the sediment trap will be removed and those areas regraded as well. |
2301635 | Primary Facility | 2014-09-02 | Routine/Complete Inspection | No Violations Noted | |
2307238 | Primary Facility | 2014-09-26 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed at the time of the inspection. Wells appeared to be equipped for production. Brine tanks located onsite within containment. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. All cut and fill slopes had been stabilized with vegetation as had the area which had been utilized for below grade impoundment. |
2348593 | Primary Facility | 2015-03-03 | Routine/Complete Inspection | No Violations Noted | Well appeared ot be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimenation in relation to the site or access road. |
2413921 | Primary Facility | 2015-10-07 | Incident- Response to Accident or Event | Violation(s) Noted | |
2419538 | Primary Facility | 2015-10-28 | Administrative/File Review | Outstanding Violations - No Viols Req'd | This inspection is to document that the Department has received EQT's response outlining the interim remedial actions undertaken and the decision by EQT to utilize the alternate remediation option outlined in the Department's Policy on Addressing Spills and Releases at Oil & Gas Well Sites or Access Roads. At this time the Department is requesting that by January 4, 2016, EQT submit the narrative and sample analysis documentation for the confirmatory and background samples taken as part of the remedial actions related to this spill. This documentation should be sent to the attention of WQS Gregory Higgins at the above listed address. |
2436590 | Primary Facility | 2015-12-29 | Routine/Complete Inspection | No Violations Noted | Well is tagged-in production. Well casing-equipment-tank battery-dike-production units all OK. |
2451939 | Primary Facility | 2016-02-23 | Compliance Evaluation | No Violations Noted | The Department has received and is reviewing the alternative process remediation report related to the release from October 2015. The site had been properly regraded and regraveled. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tank located onsite and it appeared to be in sound condition. |
2560241 | Primary Facility | 2017-02-09 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok. |
2615310 | Primary Facility | 2017-07-14 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2658922 | Primary Facility | 2017-11-09 | Routine/Complete Inspection | No Violations Noted | Multi-well pad. At time of inspection, well drilled and appears equipped for production. |
2709195 | Primary Facility | 2018-03-23 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, tank battery and containment dike look ok. |
2820940 | Primary Facility | 2019-01-02 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production with the annulus open. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2002332 | 620070 | 09/07/2011 | 2011-09-07 | 78.83COALCSG - Improper coal protective casing and cementing procedures | Administrative | |
2413921 | 736365 | 10/07/2015 | 2015-10-07 | 78.57(a) - CONTROL, STORAGE AND DISPOSAL OF PRODUCTION FLUIDS - Operator failed to collect the brine and other fluids produced during operation, service and plugging of the well in a tank, pit or a series of pits or tanks, or other device approved by | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
620070 | 274835 | NOV - Notice of Violation | Unresolvable | 2011-11-07 | |||
620070 | 295543 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2013-03-21 | 2013-03-21 | $50,000.00 | $50,000.00 |
736365 | 330266 | NOV - Notice of Violation | |||||
736365 | 362113 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2018-03-05 | $10,000.00 | $10,000.00 |
For data sources see[8]