Well Details

Well ID: 37-005-30851
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: East Franklin Township
Operator Name: SNYDER BROS INC
Well Pad ID: 146033
Farm/Lease Name: C H SNYDER COMPANY 4-135
License Status:
Spud Date:
Permit Date: 2011-06-20
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.877686
Longitude: -79.516817

For data sources see[1][2][3]

Well History

Date Event
2011-06-20 New Permit Application
2012-01-18 Performed Spud Operation
2012-01-27 Drilling Completion
2012-05-29 Perforation
2012-10-26 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-05-31 2012-05-31 6,698 154,888

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WFR-3B Superior Well Services Friction Reducer Stoddard solvent 8052-41-3 10.00 0.00731280
Ethoxylated C12-16 alcohols 68551-12-2 4.00 0.00292510
1,2-Propylene glycol 57-55-6 25.00 0.01
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
ICP-1000 Superior Well Services Iron Control Additive 1,2-Propylene glycol 57-55-6 50.00 0.00484290
ANIONIC COPOLYMER 50.00 0.00484290
Hydrochloric Acid Superior Well Services Cement/Formation Breakdown Water 7732-18-5 92.50 0.22
Hydrochloric acid 7647-01-0 7.50 0.01
SUPER MAX Superior Well Services Surfactant 2-Ethylhexanol 104-76-7 40.00 0.00019370
Isopropanol 67-63-0 30.00 0.00014530
2-Butoxyethanol 111-76-2 7.00 0.00003390
PROPRIETARY 7.00 0.00003390
Super 100NE Superior Well Services Surfactant/Foamer 2-Butoxyethanol 111-76-2 7.00 0.00728860
Isopropanol 67-63-0 30.00 0.03
SUPER TSC Superior Well Services Scale Control ANIONIC COPOLYMER 10.00 0.00033900
CLAY TREAT LT Superior Well Services Clay Control Choline chloride 67-48-1 80.00 0.00038740
ACID INHIBITOR 2 Superior Well Services Acid Corrosion Inhibitor 2-Butoxyethanol 111-76-2 0.00021790
PROPRIETARY 0.00005090
Propargyl alcohol 107-19-7 0.00021790
Isopropanol 67-63-0 0.00021790
SUPER MAX Superior Well Services Surfactant/Foamer
KR-153SL Superior Well Services Biocide Diethylene glycol 111-46-6 3.50 0.00011870
Ethylene glycol 107-21-1 1.00 0.00003390
Polyethylene glycol 25322-68-3 50.00 0.00169500
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00067800
SUPER TSC Superior Well Services Paraffin & Scale Additive 1,2-Propylene glycol 57-55-6 50.00 0.00169500
ANIONIC POLYMER 10.00 0.00033900
1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1 10.00 0.00033900
SUPER MAX Superior Well Services Foamer

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2012 SNYDER BROS INC 56,549.00 156 0.00 0 0.00 0
2013 SNYDER BROS INC 57,894.00 363 0.00 0 0.00 0
2014 SNYDER BROS INC 32,486.00 362 0.00 0 0.00 0
2015 SNYDER BROS INC 27,722.00 353 0.00 0 0.00 0
2016 SNYDER BROS INC 22,875.00 357 0.00 0 0.00 0
2017 SNYDER BROS INC 18,941.00 350 0.00 0 0.00 0
2018 SNYDER BROS INC 15,194.00 357 0.00 0 0.00 0
2019 SNYDER BROS INC 14,349.00 353 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SNYDER BROS INC Produced Fluid 243.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012 SNYDER BROS INC Fracing Fluid Waste 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2012 SNYDER BROS INC Drill Cuttings 109.00 Tons ON SITE ENCAPSULATION
2012 SNYDER BROS INC Fracing Fluid Waste 230.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW008
2012 SNYDER BROS INC Fracing Fluid Waste 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SNYDER BROS INC Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-155-23584
2012 SNYDER BROS INC Fracing Fluid Waste 180.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 525-1
2012 SNYDER BROS INC Fracing Fluid Waste 900.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013 SNYDER BROS INC Produced Fluid 177.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 SNYDER BROS INC Produced Fluid 83.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2015 SNYDER BROS INC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015 SNYDER BROS INC Produced Fluid 60.00 Bbl CENT WASTE TRT FAC NPDES PA0095443
2015 SNYDER BROS INC Produced Fluid 60.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2018 SNYDER BROS INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-099-23158

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2067666 Primary Facility 2012-05-14 Routine/Complete Inspection No Violations Noted At the time of inspection the well appears to drilled but does not appear to be equipped for production. The Department notes that at the time of inspection the drill pit located onsite appears to be in sound condition with the required 2 feet of freeboard. At the time of inspection the E&S plan was onsite and appears to properly implemented and maintained. No accelerated erosion observed in relation to the access road or well pad area.
2082449 Primary Facility 2012-07-11 Routine/Complete Inspection No Violations Noted At the time of inspection the well appears to drilled and equipped for production. The well apparatus and brine tanks located onsite appear to be in sound condition. The Department notes that at the time of inspection the drill pit located onsite appears to be in sound condition with the required 2 feet of freeboard. At the time of inspection the E&S plan was onsite and appears to properly implemented and maintained. No accelerated erosion observed in relation to the access road or well pad area.
2121476 Primary Facility 2012-12-06 Routine/Complete Inspection No Violations Noted Well operating and properly identified.
2173561 Primary Facility 2013-06-07 Site Restoration No Violations Noted Well appeared to be equipped for production. Brine tanks located on-site and they appeared to be in sound condition. Site had been properly restored and the vegetative cover met the 70% uniform coverage criteria. There was no evidence observed of accelerated erosion or sedimentation in relation to the site or access road.
2173562 Primary Facility 2013-06-07 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Site and access road erosion controls appeared to be functioning properly and there was no eviedence of accelerated erosion or sedimentation. Drill pit located onsite and it contained fluids, drill cuttings and it had more than the required two feet of lined freeboard.
2291100 Primary Facility 2014-07-29 Routine/Complete Inspection No Violations Noted Well operating and properly identified.
2340354 Primary Facility 2015-02-02 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2586521 Primary Facility 2017-04-25 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.