If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30953 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.01965,"lon":-79.682586,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Perry Township | |
Operator Name: DANNIC ENERGY CORP | |
Well Pad ID: | |
Farm/Lease Name: HILES 1 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-12-09 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.019650 | |
Longitude: -79.682586 |
Date | Event |
---|---|
2011-12-09 | New Permit Application |
2012-03-26 | Performed Spud Operation |
2012-03-30 | Drilling Completion |
2012-11-20 | Perforation |
2013-05-29 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | DANNIC ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | DANNIC ENERGY CORP | 700.96 | 214 | 0.00 | 0 | 0.00 | 0 |
2013 | DANNIC ENERGY CORP | 6,190.20 | 304 | 0.00 | 0 | 0.00 | 0 |
2014 | DANNIC ENERGY CORP | 3,215.00 | 304 | 0.00 | 0 | 0.00 | 0 |
2015 | DANNIC ENERGY CORP | 2,185.99 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | DANNIC ENERGY CORP | 2,375.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | DANNIC ENERGY CORP | 1,862.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | DANNIC ENERGY CORP | 1,736.08 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | DANNIC ENERGY CORP | 1,773.80 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | DANNIC ENERGY CORP | Produced Fluid | 740.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2054229 | Primary Facility | 2012-03-27 | Routine/Complete Inspection | Violation(s) Noted | Inspection in response to a spud notice received on 3/25/2012. At the time of inspection the drill rig was on site. Drilling was not ongoing at the time of the inspection. The Department notes that the implemented E&S controls are not adequate due as a result of recent precipitation events and two naturally occurring springs encountered during site construction. Due to the failure to capture and convey the two springs and runoff flow, the silt fencing had been compromised resulting in offsite transport of sediment. |
2067126 | Primary Facility | 2012-04-26 | Compliance Evaluation | No Violations Noted | Follow up to previous site inspection in response to violations written on 3/27/2012. At the time of inspection the well appears to be drilled and equipped for production. The Department notes that some of the recommendations from the previous inspection were followed. The silt fence has been replaced. |
2172261 | Primary Facility | 2013-06-05 | Routine/Complete Inspection | Violation(s) Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been regraded, however the vegetation did not meet the 70% uniform coverage criteria. There was no observed accelerated erosion or sedimentation in relation to the site or access road. In addition it was noted that the well was not properly labeled. |
2198518 | Primary Facility | 2013-08-22 | Compliance Evaluation | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been regraded, and the vegetative cover met the 70% uniform coverage criteria. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2054229 | 635408 | 03/27/2012 | 2012-03-27 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | 78.53 |
2172261 | 669716 | 06/05/2013 | 2013-06-05 | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | Administrative | |
2172261 | 669718 | 06/05/2013 | 2013-06-05 | 102.22 - Failure to achieve permanent stabilization of earth disturbance activity. | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
635408 | 281921 | NOV - Notice of Violation | Comply/Closed | 2019-01-17 | |||
669716 | 298407 | NOV - Notice of Violation | Comply/Closed | 2013-08-22 | |||
669718 | 298407 | NOV - Notice of Violation | Comply/Closed | 2013-08-22 |
For data sources see[7]