Well Details

Well ID: 37-005-31082
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: West Franklin Township
Operator Name: SNYDER BROS INC
Well Pad ID: 147121
Farm/Lease Name: FLEEGER UNIT 1M-107.6
License Status:
Spud Date:
Permit Date: 2012-07-25
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.889942
Longitude: -79.645017

For data sources see[1][2][3]

Well History

Date Event
2012-07-25 New Permit Application
2012-09-07 Performed Spud Operation
2012-09-19 Drilling Completion
2013-07-16 Perforation
2014-04-10 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-07-18 2013-07-18 5,976 95,216 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Nitrogen per MSCF Nabors Completion and Production Services Nitrogen Materials Nitrogen 7727-37-9 100 28.9126 0
PA Specific 40/70 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Iron Oxide 1309-37-1 0.1 0.013859 0
Crystalline Silica, quartz 14808-60-7 99.9 13.8449 0
Titanium Oxide 13463-67-7 0.1 0.013859 0
Aluminum Oxide 1344-28-1 1.1 0.152446 0
HCL Acid (0%-7.5%) Nabors Completion and Production Services Bulk Acid Hydrogen Chloride 7647-01-0 7.5 0.019608 0
Water 7732-18-5 92.5 0.241831 0
WFR-3B Nabors Completion and Production Services Friction Reducer Hydrotreated light distillates, non-aromatic, BTEX free 64742-47-8 30 0.029088 0
Ethoxylated alcohols 68002-97-1 15 0.014544 0
Ethoxylated oleylamine 26635-93-8 5 0.004848 0
PA Specific 30/50 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Crystalline Silica, quartz 14808-60-7 99.9 8.50219 0
Aluminum Oxide 1344-28-1 1.1 0.093618 0
Titanium Oxide 13463-67-7 0.1 0.008511 0
Iron Oxide 1309-37-1 0.1 0.008511 0
Water SNYDER BROTHERS INC Water Water 7732-18-5 100 48.2051 0
KR-153SL Nabors Completion and Production Services Biocides 2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.001109 0
Polyethlyene-Glycol 25322-68-3 50 0.002773 0
Other Ingredients Nabors Completion and Production Services Other Ingredients Polymer Proprietary 1 0.001305 0
Proprietary Proprietary 100 0.130474 0
Monoethanolamine Proprietary 100 0.001305 0
Water 7732-18-5 48 0.000481 0
Alkyl Phosphate Ether Proprietary 1 0.001305 0
Solvent Proprietary 1 0.001305 0
Proprietary Proprietary 15 0.000765 0
Anionic Polyacrylamide 910644-97-2 40 0.038784 0
Dioxane 123-91-1 1 0.00001000 0
Propylene glycol 57-55-6 15 0.014544 0
Proprietary Proprietary 50 0.002549 0
Demineralized Water 7732-18-5 50 0.000549 0
ammonium, (2-Hydroxyethyl)trimethyl-, chloride 67-48-1 80 0.000878 0
2-Butoxyethanol 111-76-2 13 0.00013 0
Proprietary Proprietary 2 0.001939 0
Proprietary Proprietary 1 0.001305 0
Water 7732-18-5 60 0.003059 0
Water 7732-18-5 40 0.038784 0
Water 7732-18-5 50 0.065237 0
Ammonium salts Proprietary 100 0.026095 0
Polymer Proprietary 10 0.013047 0
Phosphoric Acid 7664-38-2 100 0.001305 0
Water 7732-18-5 80 0.004436 0
ICP-1000 Nabors Completion and Production Services Iron Control Additives Anionic Copolymer Proprietary 50 0.005603 0
Propylene glycol 57-55-6 50 0.005603 0
Acid Inhibitor 2 (AI-2) Nabors Completion and Production Services Acid Corrosion Inhibitors Ethoxylated Nonylphenol 68412-54-4 13 0.00013 0
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 10 0.0001 0
Isopropyl Alcohol 67-63-0 40 0.000401 0
Glycol Ethers 111-46-6 40 0.000401 0
Propargyl Alcohol 107-19-7 40 0.000401 0
Super 100 NE Nabors Completion and Production Services Surfactants & Foamers Isopropyl Alcohol 67-63-0 40 0.052189 0
N-Cocoamidopropyl-N,N-dimethyl-N-2-hydroxypropylsulfobetaine
68139-30-0 15 0.019571 0
Methanol 67-56-1 15 0.019571 0
Glycol Ether 111-76-2 5 0.006524 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2013 SNYDER BROS INC 30,346.00 131 0.00 0 0.00 0
2014 SNYDER BROS INC 42,589.00 363 0.00 0 0.00 0
2015 SNYDER BROS INC 25,172.00 357 0.00 0 0.00 0
2016 SNYDER BROS INC 22,211.00 359 0.00 0 0.00 0
2017 SNYDER BROS INC 20,723.00 358 0.00 0 0.00 0
2018 SNYDER BROS INC 14,828.00 360 0.00 0 0.00 0
2019 SNYDER BROS INC 12,403.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SNYDER BROS INC Drill Cuttings 105.00 Tons ON SITE ENCAPSULATION
2013 SNYDER BROS INC Fracing Fluid Waste 1,220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW006
2013 SNYDER BROS INC Produced Fluid 177.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2013 SNYDER BROS INC Produced Fluid 120.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW006
2013 SNYDER BROS INC Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2015 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2016 SNYDER BROS INC Produced Fluid 60.00 Bbl REUSE OTHER THAN ROAD SPREADING
2019 SNYDER BROS INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-099-23158

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2098847 Primary Facility 2012-09-11 Routine/Complete Inspection No Violations Noted At the time of inspection the drill rig was onsite and was properly placed on containment. The drill pit located onsite appeared to be in sound condition with the required 2 feet of freeboard. The E&S plan was also onsite and all BMPs appeared to be in sound condition and installed per the approved plan. No accelerated erosion or sedimentation observed in relation to the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the site stability in maintained.
2100951 Primary Facility 2012-09-19 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drilled however was not stimulated or equipped for production. The drill pit located onsite appeared to be in sound condition with the required 2 feet of freeboard. The E&S plan was also onsite and all BMPs appeared to be in sound condition and installed per the approved plan. No accelerated erosion or sedimentation observed in relation to the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the site stability in maintained.
2134702 Primary Facility 2013-01-30 Drilling/Alteration No Violations Noted Well shut in on 4 1/2” x 2” swage. Pit lined and freeboard maintained.
2170513 Primary Facility 2013-05-24 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it contained fluids and drill cuttings. Drill pit had more than the required two feet of lined freeboard. Drill pit liner appeared to be intact. E&S controls ahd been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road.
2178222 Primary Facility 2013-06-26 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it contained fluids and drill cuttings. Drill pit had more than the required two feet of lined freeboard. Drill pit liner appeared to be intact. E&S controls ahd been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. The Department recommends that the operator inspect the access road and its erosion controls for any necessary maintenance or repairs after the recent storm events.
2196968 Primary Facility 2013-08-13 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks were located and they appeared to be in sound condition. E&S controls had been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road.
2212599 Primary Facility 2013-10-15 Site Restoration No Violations Noted Well appeared to be equipped for production. Brine tanks were located and they appeared to be in sound condition. E&S controls had been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. Site had been seeded, mulched and the vegetation had begun to take hold. There were several areas on the fill slope where the seed has not yet germinated. The operator should monitor this area and if necessary re-seed and mulch.
2365829 Primary Facility 2015-04-30 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2765081 Primary Facility 2018-08-20 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and two grounded 100 bbl fiberglass fluid collection tanks look ok.

For data sources see[8]