Well Details

Well ID: 37-009-20085
Loading map...
Country: United States
State: Pennsylvania
County: Bedford
Municipality: West Saint Clair Township
Operator Name: LPR ENERGY LLC
Well Pad ID: 146390
Farm/Lease Name: DAVIS UNIT
License Status: INACTIVE
Spud Date: 2010-10-07
Permit Date: 2010-09-02
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.196381
Longitude: -78.661111

For data sources see[1][2][3]

Well History

Date Event
2010-09-02 New Permit Application
2010-10-07 Performed Spud Operation
2010-11-11 Drilling Completion
2012-07-20 DEVIATED
2019-08-15 Inactive Well Request Granted

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2015 LPR ENERGY LLC 0.00 0 0.00 0 0.00 0
2016 LPR ENERGY LLC 0.00 0 0.00 0 0.00 0
2017 LPR ENERGY LLC 0.00 0 0.00 0 0.00 0
2019 LPR ENERGY LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHIEF OIL & GAS LLC Drilling Fluid Waste 91.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2011 CHIEF OIL & GAS LLC Drill Cuttings 572.54 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1915130 Primary Facility 2010-09-23 Drilling/Alteration De minimus Violations Noted Well will be Spud 9/24/10. Permit number not on site ID sign.
1919970 Primary Facility 2010-10-05 Drilling/Alteration No Violations Noted UDI rig 59 cementing 13 3/8" casing 20 Bbls return to surface
1919971 Primary Facility 2010-10-12 Complaint Inspection No Violations Noted UDI rig 59 is currently broke down. Gear box for the drawworks burnt up due to oil pumps failing.
1924072 Primary Facility 2010-10-27 Drilling/Alteration No Violations Noted UDI 59 drilliing 8 3/4" hole @ 4939' vertically
1924726 Primary Facility 2010-10-06 Routine/Complete Inspection No Violations Noted
1929514 Primary Facility 2010-10-29 Routine/Complete Inspection De minimus Violations Noted
1932162 Primary Facility 2010-11-29 Routine/Complete Inspection No Violations Noted Pilot hole drilled. well capped waiting to finish drilling
1939597 Primary Facility 2010-12-28 Routine/Complete Inspection Violation(s) Noted
1942989 Primary Facility 2010-11-15 Routine/Complete Inspection No Violations Noted
1948173 Primary Facility 2011-01-04 Compliance Evaluation Outstanding Violations - No Viols Req'd
1963268 Primary Facility 2011-02-23 Compliance Evaluation Outstanding Violations - No Viols Req'd
1965677 Primary Facility 2011-03-03 Compliance Evaluation No Violations Noted
1986202 Primary Facility 2011-05-11 Routine/Complete Inspection No Violations Noted
2020191 Primary Facility 2011-09-13 Routine/Complete Inspection No Violations Noted
2024349 Primary Facility 2011-10-05 Routine/Complete Inspection No Violations Noted
2058934 Primary Facility 2012-03-08 Routine/Complete Inspection No Violations Noted
2129942 Primary Facility 2013-01-10 Routine/Complete Inspection No Violations Noted
2176918 Primary Facility 2013-06-19 Routine/Complete Inspection No Violations Noted
2697681 Primary Facility 2018-02-23 Routine/Complete Inspection No Violations Noted Routine site inspection at LPR Energy's Davis Unit Pad on February 23, 2018. No one was onsite during my inspection.

The site sign was present at the access road entrance right off SR 56 (Quaker Valley Road). I found old PPC plans, Emergency Response (ER) plan, and a well permit issued under previous owners (Chief and Chevron). I recommend that PPC and ER plans be updated to reflect current operator/contact information.

According to Department records, there is no ESCGP associated with the construction of the well pad and access road; only an E & S plan. The well pad remains at full built out size. Ditches and sediment traps have been installed per the E & S plans.

There is one drilled well onsite (009-20085). This well was issued regulatory inactive status (RIAS) on January 29, 2013. The regulatory inactive status just expired for well 009-20085. I recommend contacting the Departments Oil and Gas Inspector regarding extending this expired RIAS well or for other alternative methods.

No production equ

2703423 Primary Facility 2018-03-09 Routine/Complete Inspection No Violations Noted The weather is 30 Deg. F, snowing and windy at time of inspection. Routine inspection of LPR Energy LLC., Davis Unit Pad, 1H Well on March 9, 2018.

There is one wells on this pad, currently shut in and has regulatory inactive status. Annulus is closed and vented into the poly tank at time of inspection. 100% LEL and 3% combustible gas was detected at the poly tank, 0% combustible gas was detected at the annulus or in the area immediately surrounding the well. There is no production equipment in site. No violations noted at the time of inspection. DEP Representatives ¿ Ulyana Trynovich, Oil and Gas Inspector.

2841568 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at LPR Energy's Davis Unit Pad on February 19, 2019. No one was onsite during my inspection.

According to Department records, there is no ESCGP associated with the construction of the well pad and access road; only an E & S plan. The well pad remains at full built out size. Ditches and sediment traps have been installed per the E&S plans. The entire site was snow/ice covered. No E&S issues observed.

There is one drilled well onsite (009-20085). This well was issued regulatory inactive status (RIAS) on January 29, 2013. An extension of RIAS was granted by the Department on May 14, 2018. The extension is only good for 1 year (May 13, 2019). No production equipment is onsite. There is currently no pipeline constructed to this well pad.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1939597 602145 12/28/2010 2010-12-28 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Drilling mud was released from a transfer hose when damaged by a fork truck being driven over the hose

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
602145 266578 NOV - Notice of Violation Comply/Closed 2011-03-03

For data sources see[7]