37-015-22147

Well Details

Well ID: 37-015-22147
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Pike Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 146763
Farm/Lease Name: STASIAK UNIT 1H
License Status:
Spud Date:
Permit Date: 2012-03-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.798056
Longitude: -76.162278

For data sources see[1][2][3]

Well History

Date Event
2012-03-14 New Permit Application
2012-06-07 Performed Spud Operation
2013-05-09 Perforation
2014-01-07 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-06-09 2013-06-15 6,399 6,810,550
2 2012-08-19 2012-08-19 6,398 1,521,912

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 J609 Schlumberger Friction Reducer Ammonium Sulfate 7783-20-2 30 0.03 0
MCS-2510T MULTI-CHEM Scale Inhibitor ETHYLENE GLYCOL 107-21-1 60 0.004 0
MCB-8614 MULTI-CHEM BIOCIDE ALKYL (C12-16) DIMETHYLBENZXYLAMMONIUM CHLORIDE 68424-85-1 5 0.002 0
GLUTARALDEHYDE 111-30-8 30 0.01 0
H015 Schlumberger Acid Hydrochloric Acid 7647-01-0 15 0.14 0
Water Provided by Customer Base Fluid Fresh Water 0000-00-0 100 99.81 0
2 Sand (Proppant) Halliburton Energy Services Propping Agent
Quartz 14808-60-7 99.90 30.55
Water Base Fluid Fresh Water 100.00 68.94
Biocide - Bactron K 139 Champion Technologies Biocide Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 10.00
Ethanol 64-17-5 5.00
Glutaraldehyde 111-30-8 5.00 0.06
Gyptron T-390 Champion Technologies Scale Inhibitor
FRW-66 Halliburton Energy Services Friction Reducer
Hydrotreated Light Distillate
64742-47-8
0.05
Hydrochloric Acid 28 Halliburton Energy Services Acid Water

7732-18-5 85
Hydrochloric acid 7647-01-0 0.39
Gyptron T-390 Champion Technologies Halliburton Energy Services Scale Inhibitor
Methanol

67-56-1 10.00
0.01

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 812,127.06 194 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,514,238.51 365 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 1,111,611.85 364 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 704,691.78 365 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 557,105.14 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHIEF OIL & GAS LLC Drill Cuttings 10.74 Tons LANDFILL 301358
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 834.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Drill Cuttings 1,500.62 Tons LANDFILL 100933
2013 CHIEF OIL & GAS LLC Fracing Fluid Waste 1,449.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Fracturing Fluid Waste 10.76 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2014 CHIEF OIL & GAS LLC Produced Fluid 14.17 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 7,711.98 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Fracing Fluid Waste 120.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 CHIEF OIL & GAS LLC Fracturing Fluid Waste 30.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 CHIEF OIL & GAS LLC Produced Fluid 2,711.26 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 804.78 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Produced Fluid 106.78 Bbl REUSE OTHER THAN ROAD SPREADING
2018 CHIEF OIL & GAS LLC Produced Fluid 232.52 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 197.24 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2081914 Primary Facility 2012-06-18 Drilling/Alteration No Violations Noted UDI 58 - AT 852' AT TIME OF INSPECTION
2184208 Primary Facility 2013-07-11 Routine/Complete Inspection No Violations Noted
2289454 Primary Facility 2014-07-10 Routine/Complete Inspection No Violations Noted
2289876 Primary Facility 2014-07-24 Routine/Complete Inspection No Violations Noted
2301926 Primary Facility 2014-09-06 Routine/Complete Inspection No Violations Noted
2305125 Primary Facility 2014-09-18 Routine/Complete Inspection No Violations Noted
2321115 Primary Facility 2014-10-31 Routine/Complete Inspection No Violations Noted
2327097 Primary Facility 2014-12-04 Routine/Complete Inspection No Violations Noted
2327296 Primary Facility 2014-11-21 Routine/Complete Inspection No Violations Noted I met with Roger Webb, Company Man and consultant of Chief Oil and Gas. Team Services Rig #126 is in the process of drilling out frac plugs on the 4H well. Fresh water, which is used in the process of drilling out frac plugs, had frozen in the well during drilling. The process which commenced today has been temporarily halted in order to heat the water according to Mr. Webb. There is a (330) gallon capacity tote container more than half empty of liquid stored on the ground surface near the access road. The tote is stored on top of soil excavated for an underground gathering pipeline. The liquid material in the tote may have been used to perform maintenance operations (pigging) of the pipeline according to Mr. Webb. A section of the containment berm in front of the Service Rig is not completely secured and some areas of compromised liner integrity were observed.
2334907 Primary Facility 2015-01-08 Follow-up Inspection No Violations Noted
2350572 Primary Facility 2015-03-10 Follow-up Inspection No Violations Noted
2511163 Primary Facility 2016-08-11 Routine/Complete Inspection No Violations Noted
2607914 Primary Facility 2017-06-19 Routine/Complete Inspection No Violations Noted On June 19, 2017 at 1100 hrs., the Department conducted a routine inspection at the Chief Oil & Gas LLC, Stasiak Well Pad location in Pike and Stevens Townships, Bradford County. Andrew Hobbins, Water Quality Specialist, represented the Department. Nobody was present for Chief.

The site sign, E & S plan and weekly inspection logs were on site and available for review. The was observed to be well vegetated in certain areas and rock/shale lined in other locations. No erosion issues were observed.

Four wells were in production during the inspection. The wells were labeled and no bubbling was observed in the well cellars. Four production tanks and four GPUs were on secondary containment. Puddles on the pad surface tested low in specific conductivity. No staining was observed on the well pad surface.

On December 3, 2014 three violations were cited for puddles on the well pad surface that had elevated conductivity. Samples taken from the puddles confirmed the release of a pollutional substance. Fo

2637313 Primary Facility 2017-09-05 Site Restoration No Violations Noted On September 5, 2017, the Department conducted a site restoration inspection at the Chief Oil & Gas LLC, Stasiak Well Pad in Stevens Township, Bradford County. Andrew Hobbins represented the Department. Nobody was present for Chief. The inspection was in response to a Notice of Termination received by the Department on August 24, 2017.

Overall the site did not meet the requirements of 25 Pa Code 102.22(a)(2)(I) Permanent Stabilization. Two areas of the topsoil stockpile were not uniformly vegetated greater than 70%. In addition, the Department observed two compost filter sock BMPs installed at the eastern slope of the well pad. The Department recommends removing the E & S BMPs.

Based on the conditions observed during the inspection, it is recommended the NOT be denied.

2776767 Primary Facility 2018-09-18 Site Restoration No Violations Noted NOT approval. Chief vegetated the pad, now there is just a gravel road that loops around the wells.

I took electrical conductivity readings with an Oakton PCSTestr 35. Water on the pad is 0.30 mS/cm today. JLP

For data sources see[8]

References