37-027-21619

Well Details

Well ID: 37-027-21619
Loading map...
Country: United States
State: Pennsylvania
County: Centre
Municipality: Burnside Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 148768
Farm/Lease Name: LITKE UNIT P-4 31H
License Status:
Spud Date:
Permit Date: 2010-04-30
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.092361
Longitude: -77.955339

For data sources see[1][2][3]

Well History

Date Event
2010-04-30 New Permit Application
2010-05-24 Performed Spud Operation
2010-08-07 Drilling Completion
2010-10-23 Perforation
2012-07-23 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA INC 133,199.00 334 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 120,002.00 366 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 103,429.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 97,547.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 94,134.00 365 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 100,547.00 364 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 99,632.00 365 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 94,558.00 362 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 90,569.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 EXCO RESOURCES PA INC Produced Fluid 573.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAS2D205BCLE
2010 EXCO RESOURCES PA INC Produced Fluid 200.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 EXCO RESOURCES PA INC Produced Fluid 497.90 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2011 EXCO RESOURCES PA INC Drilling Fluid Waste 1,245.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Produced Fluid 570.72 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 EXCO RESOURCES PA INC Produced Fluid 649.86 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Fracing Fluid Waste 100.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2011 EXCO RESOURCES PA INC Produced Fluid 60.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 EXCO RESOURCES PA INC Produced Fluid 4,272.10 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAS2D205BCLE
2011 EXCO RESOURCES PA INC Fracing Fluid Waste 22,276.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Produced Fluid 78.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2011 EXCO RESOURCES PA INC Produced Fluid 1,178.02 Bbl INJECTION DISPOSAL WELL 34-119-27350
2011 EXCO RESOURCES PA INC Produced Fluid 110.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2012 EXCO RESOURCES PA LLC Produced Fluid 1,654.92 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2012 EXCO RESOURCES PA LLC Produced Fluid 212.96 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Produced Fluid 1,885.43 Bbl INJECTION DISPOSAL WELL 34-119-27350
2012 EXCO RESOURCES PA LLC Produced Fluid 104.40 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 EXCO RESOURCES PA LLC Produced Fluid 108.16 Bbl INJECTION DISPOSAL WELL 34-059-24067
2013 EXCO RESOURCES PA LLC Produced Fluid 118.32 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Produced Fluid 3,519.80 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 3,910.52 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 4,148.20 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 3,990.20 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 4,418.90 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 210.00 Bbl REUSE (AT WELL PAD)
2018 EXCO RESOURCES PA LLC Produced Fluid 662.20 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 EXCO RESOURCES PA LLC Produced Fluid 3,489.20 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 3,377.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1887312 Primary Facility 2010-05-25 Drilling/Alteration No Violations Noted US Energy Rig 4 is currently drilling 17" hole at 112'
1888125 Primary Facility 2010-05-25 Drilling/Alteration No Violations Noted
1894248 Primary Facility 2010-06-23 Drilling/Alteration No Violations Noted Top hole drilled. 9 5/8"-2" swedge installed.
1902078 Primary Facility 2010-07-30 Drilling/Alteration No Violations Noted Current depth 5806' air drilling. Location in good condition, no spills visable
1917258 Primary Facility 2010-09-08 Routine/Complete Inspection No Violations Noted
1938423 Primary Facility 2010-12-21 Compliance Evaluation Pending
1941998 Primary Facility 2010-11-08 Routine/Complete Inspection No Violations Noted
1953828 Primary Facility 2011-01-25 Routine/Complete Inspection No Violations Noted
1968737 Primary Facility 2011-03-10 Routine/Complete Inspection No Violations Noted
1986386 Primary Facility 2011-05-24 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998547 Primary Facility 2011-07-19 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998603 Primary Facility 2011-08-17 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998660 Primary Facility 2011-08-23 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998690 Primary Facility 2011-08-24 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998713 Primary Facility 2011-08-25 Compliance Evaluation Outstanding Violations - No Viols Req'd
2016779 Primary Facility 2011-08-29 Routine/Complete Inspection No Violations Noted
2019220 Primary Facility 2011-09-06 Routine/Complete Inspection No Violations Noted
2022956 Primary Facility 2011-09-23 Routine/Complete Inspection No Violations Noted
2023004 Primary Facility 2011-09-26 Routine/Complete Inspection No Violations Noted
2024274 Primary Facility 2011-10-04 Routine/Complete Inspection No Violations Noted
2065825 Primary Facility 2012-03-28 Routine/Complete Inspection No Violations Noted
2085873 Primary Facility 2012-05-25 Routine/Complete Inspection No Violations Noted
2117141 Primary Facility 2012-11-15 Routine/Complete Inspection No Violations Noted
2188332 Primary Facility 2013-07-26 Routine/Complete Inspection No Violations Noted
2487359 Primary Facility 2016-05-23 Routine/Complete Inspection No Violations Noted
2705360 Primary Facility 2018-02-21 Routine/Complete Inspection No Violations Noted The weather is 70 Deg. F, cloudy and windy at time of inspection. Routine inspection of EXCO Resources PA LLC., Litke Pad, Well # 31H on February 21, 2018. There are 4 producing wells on this pad.

Annular vent is open and vented at the time of inspection. Digital pressure gauge on the top of the production xmas tree reads 219 PSI, casing pressure gauge reads 270 psi. 100% LEL and 82% combustible gas was detected at the 5-1/2" x 2-3/8" annulus vent. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized. EXCO Resources, LLC. Representative ¿ Sam Unch, Production Operator. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

2705863 Primary Facility 2018-03-09 Routine/Complete Inspection No Violations Noted Routine site inspection at EXCO Resources LLC Litke 4 Pad on March 9, 2018.

The site sign, drilling permits, weekly E&S log, PPC plan, emergency response plan (ERP), and work description of the pad and impoundments were found onsite. Please note that the PPC plan and ERP are dated June 2013 and February 2014 respectively. The Department recommends that the operator update both plans and place a copy onsite.

There are 4 drilled and producing Marcellus wells located on the pad. All well cellars are full of gravel and each well is properly labeled. There are two series of produced fluids tanks stationed in secondary containment on this pad (photo 5). Water within containment was frozen. No signs of leaks from the containment were observed. Each tank was labeled.

Part of the well pad has been partially restored. In addition, both impoundments have been fully restored. No E&S issues were observed.

2741726 Primary Facility 2018-06-13 Routine/Complete Inspection No Violations Noted Routine site inspection at EXCO Resources LLC Litke 4 Pad on June 13, 2018.

The site sign, drilling permits, weekly E&S log, PPC plan, emergency response plan (ERP), and work description of the pad and impoundments were found onsite. Please note that the PPC plan and ERP are dated June 2013 and February 2014 respectively. The Department recommends that the operator update both plans and place a copy onsite.

There are 4 drilled and producing Marcellus wells located on the pad. All well cellars are full of gravel. There are (2) 400 bbl produced fluids tanks stationed in secondary containment on this pad. Conductivity readings in this containment were 298 uS/cm. In addition, there are (3) 200 bbl produced fluids tanks stationed in secondary containment. Conductivity in this containment was 427 uS/cm. No signs of leaks from either containment were observed. Each tank was properly labeled.

Part of the well pad has been partially restored. In addition, both impoundments have been fully restored. No E&S issues

2852694 Primary Facility 2019-03-12 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at EXCO Resources PA LLC Litke Pad 4 on March 12, 2019.

There are 4 drilled and producing Marcellus wells located on the pad. All well cellars are full of gravel and/or snow. There are (2) 400 bbl produced fluids tanks stationed in secondary containment. In addition, there are (3) 200 bbl produced fluids tanks stationed in a separate secondary containment. Frozen water was observed in both sets of produced fluids secondary containment. No signs of leaks from either containment were observed. Each produced fluids tank was labeled.

Part of the well pad has been partially restored. In addition, both impoundments (2 & 3 MG) have been fully restored and are well vegetated. No E&S issues were observed. The well pad and surrounding areas are partially snow covered.

No violations noted.

For data sources see[7]