Well ID: 37-033-20341 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.085214,"lon":-78.751718,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Clearfield | |
Municipality: Brady Township | |
Operator Name: FELMONT OIL CORP | |
Well Pad ID: | |
Farm/Lease Name: JOSEPHINE CARLSON | |
License Status: PLUGGED & ABANDONED | |
Spud Date: | |
Permit Date: | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.085214 | |
Longitude: -78.751718 |
Date | Event |
---|---|
1960-11-01 | Performed Spud Operation |
1960-11-26 | Drilling Completion |
1961-01-16 | NEWLY DRILLED |
1979-08-08 | Drilling Completion |
1979-08-21 | FULLY PLUGGED |
For data sources see[4]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2650825 | Primary Facility | 2017-10-23 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of a plugged well. The well has a 2" vent pipe 6' above ground level, tee'd at the top with one side of the tee isolated with tape. I could smell gas venting and checked the vent with an Altair 5x gas meter-- 100% gas detected. I placed my hand over the vent and did not feel any significant pressure. I attached a 0-160 PSI analog pressure gauge on the vent and monitored for several minutes. No pressure buildup noted on the gauge. I attached one side of a u-tube manometer to the vent and monitored for several minutes. There was no significant fluid differential in the u-tube observed. No gas was detected outside of the vent pipe at ground level. Well Record and Certificate of Plugging are on file. |
For data sources see[5]