37-033-26855

Well Details

Well ID: 37-033-26855
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Goshen Township
Operator Name: GREYLOCK PROD LLC
Well Pad ID: 147976
Farm/Lease Name: COLD STREAM AFFILIATES 3MH 003-26855
License Status:
Spud Date:
Permit Date: 2009-09-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.113057
Longitude: -78.406691

For data sources see[1][2][3]

Well History

Date Event
2009-09-28 New Permit Application
2010-07-24 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-03-26 2011-03-26 6,993 2,839,326

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
WG-36 GELLING AGENT Halliburton Energy Services Dry Gellant Guar gum 9000-30-0 100.00 0.06
BE-9M Halliburton Energy Services Biocide Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00080000
Methanol 67-56-1 30.00 0.00241000
Water ECA Base Fluid 90.51
Sand-Premium Plus, 100 Mesh, HES Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 2.57
Sand-Premium Plus, 40/70, HES Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 6.73
HAI-OS ACID INHIBITOR Halliburton Energy Services Corrosion Inhibitor for Acid Propargyl alcohol 107-19-7 10.00 0.00008000
Methanol 67-56-1 60.00 0.00048000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00247000
GBW-30 BREAKER Halliburton Energy Services Breaker Carbohydrates 95.00 0.00127000
Hemicellulase enzyme 9012-54-8 15.00 0.00020000
15 HCl TH Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 15.00 0.07
FE-2A Halliburton Energy Services Iron Control for Acid Citric acid 77-92-9 60.00 0.00059000
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00236000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 ENERGY CORP OF AMER 0.00 0 0.00 0 0.00 0
2010 ENERGY CORP OF AMER 0.00 0 0.00 0 0.00 0
2011 ENERGY CORP OF AMER 51,682.00 152 0.00 0 0.00 0
2012 ENERGY CORP OF AMER 59,131.00 346 0.00 0 0.00 0
2013 ENERGY CORP OF AMER 48,657.00 331 0.00 0 0.00 0
2014 ENERGY CORP OF AMER 42,832.00 361 0.00 0 0.00 0
2015 ENERGY CORP OF AMER 18,438.00 142 0.00 0 0.00 0
2016 ENERGY CORP OF AMER 19,059.00 138 0.00 0 0.00 0
2017 ENERGY CORP OF AMER 39,121.00 306 0.00 0 0.00 0
2018 GREYLOCK PROD LLC 39,772.00 365 0.00 0 0.00 0
2019 GREYLOCK PROD LLC 39,604.00 362 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 ENERGY CORP OF AMER Produced Fluid 12,336.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 ENERGY CORP OF AMER Fracing Fluid Waste 6,750.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2011 ENERGY CORP OF AMER Fracing Fluid Waste 8,935.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 ENERGY CORP OF AMER Produced Fluid 31,198.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 ENERGY CORP OF AMER Produced Fluid 8,550.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 ENERGY CORP OF AMER Fracing Fluid Waste 12,650.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 ENERGY CORP OF AMER Produced Fluid 22,674.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ENERGY CORP OF AMER Fracturing Fluid Waste 88.67 Tons LANDFILL 101534
2014 ENERGY CORP OF AMER Fracturing Fluid Waste 40.40 Tons LANDFILL 101397
2014 ENERGY CORP OF AMER Fracturing Fluid Waste 62.38 Tons LANDFILL 100361
2014 ENERGY CORP OF AMER Produced Fluid 32,176.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ENERGY CORP OF AMER Fracturing Fluid Waste 54.05 Tons LANDFILL 100434
2015 ENERGY CORP OF AMER Produced Fluid 4,338.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ENERGY CORP OF AMER Produced Fluid 270.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 ENERGY CORP OF AMER Produced Fluid 390.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 ENERGY CORP OF AMER Produced Fluid 930.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2017 ENERGY CORP OF AMER Produced Fluid 3,069.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 ENERGY CORP OF AMER Produced Fluid 2,970.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 ENERGY CORP OF AMER Produced Fluid 218.00 Bbl REUSE (AT WELL PAD)
2019 GREYLOCK PROD LLC Produced Fluid 2,941.00 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019 GREYLOCK PROD LLC Produced Fluid 417.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 GREYLOCK PROD LLC Produced Fluid 469.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 GREYLOCK PROD LLC Produced Fluid 237.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1900527 Primary Facility 2010-07-23 Drilling/Alteration No Violations Noted Ransom Drilling Drilling rathole. 24" hole at 11'. Having hard time drilling through rock.
1925478 Primary Facility 2010-11-04 Compliance Evaluation No Violations Noted
1927769 Primary Facility 2010-11-12 Compliance Evaluation No Violations Noted
1932077 Primary Facility 2010-12-03 Routine/Complete Inspection Pending Bubbling in cellar, waiting for water in cellar to be drained. Black water seen leaking from containment under drilling mud tanks and flowing into diversion ditch during rainstorm
1932082 Primary Facility 2010-12-06 Routine/Complete Inspection Violation(s) Noted Methane migrated to surface through cement in 9 5/8" annulus.
1960980 Primary Facility 2011-03-29 Compliance Evaluation No Violations Noted
2119226 Primary Facility 2012-11-29 Routine/Complete Inspection No Violations Noted
2119722 Primary Facility 2012-11-29 Routine/Complete Inspection No Violations Noted
2136563 Primary Facility 2013-02-05 Routine/Complete Inspection No Violations Noted
2174912 Primary Facility 2013-06-13 Routine/Complete Inspection No Violations Noted
2217555 Primary Facility 2013-10-30 Routine/Complete Inspection No Violations Noted
2245439 Primary Facility 2014-02-13 Routine/Complete Inspection No Violations Noted
2275144 Primary Facility 2014-05-30 Routine/Complete Inspection No Violations Noted
2353826 Primary Facility 2015-03-23 Routine/Complete Inspection No Violations Noted
2371796 Primary Facility 2015-05-21 Routine/Complete Inspection No Violations Noted
2400443 Primary Facility 2015-08-19 Routine/Complete Inspection No Violations Noted
2696075 Primary Facility 2018-02-20 Routine/Complete Inspection No Violations Noted The weather is 63 Deg. F and sunny at time of inspection.

Routine inspection of Greylock Energy, Coldstream Affiliates Pad, well number 1MH on February 20, 2018. There are two producing wells on this pad. Two annulus vents (9.625 in. x 5.5 in.) are closed and not vented at time of inspection. Annulus vent (13.37 in. x 9.625 in.) is closed and vented into the tank. 100% LEL and 25% combustible gas was detected at the gas separator area during inspection. Followed up with company representative via the phone regarding gas equipment leak. Wellsite looks neat and well organized. No violations noted at the time of inspection. DEP Representative ¿ Ulyana Trynovich, Oil and Gas Inspector.

2701875 Primary Facility 2018-03-06 Routine/Complete Inspection No Violations Noted The weather is 40 Deg. F and sunny at time of inspection.

Follow up inspection of Greylock Energy, Coldstream Affiliates Pad, well number 1MH on March 6, 2018. There are two producing wells on this pad. Two annulus vents (9.625 in. x 5.5 in.) are closed and not vented at time of inspection. Annulus vent (13.37 in. x 9.625 in.) is closed and vented into the tank. The production tree top pressure is 92 psi. 100% LEL and 96% combustible gas was detected at the dump level controller on the separator during inspection. Physically could sense the gas odor approximately from 5 ft. away from the gas leak source. Gas rate intensity is much lower compare to the rate intensity during previous inspection. Followed up with company representative via the phone regarding gas equipment leak. No violations noted at the time of inspection. DEP Representative ¿ Ulyana Trynovich, Oil and Gas Inspector.

2729885 Primary Facility 2018-05-15 Routine/Complete Inspection No Violations Noted The weather is 72 Deg. F and sunny at time of inspection.

Routine inspection of Greylock Energy, Coldstream Affiliates Pad, well number 3MH on May 15, 2018. There are two producing wells on this pad. Two annulus vents (9.625 in. x 5.5 in.) are closed and not vented at time of inspection. Annulus vent (13.37 in. x 9.625 in.) is closed and vented into the tank. The production Xmas tree top pressure gauge reads 64 psi. 0% combustible gas was detected in the area during inspection. Missing bolt at the dump level controller has been replaced, where 100% LEL and 6% combustible gas was detected, but I did not sense any gas odor around gas separator unit. No violations noted at the time of inspection. DEP Representative Ulyana Trynovich, Oil and Gas Inspector.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1932082 600725 12/06/2010 2010-12-06 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
600725 265809 NOV - Notice of Violation

For data sources see[8]

References