37-051-20045

Well Details

Well ID: 37-051-20045
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Wharton Township
Operator Name:
Well Pad ID:
Farm/Lease Name: R. E. EBERLY UW-204
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 1996-07-29
Well Type: DRY HOLE
Unconventional Well: N
Configuration: Vertical Well
Conservation: Yes
Latitude: 39.793141
Longitude: -79.6908

For data sources see[1][2][3]

Well History

Date Event
1964-08-17 Drilling Completion
1964-09-01 NEWLY DRILLED
1996-07-29 New Permit Application
1996-11-17 Drilling Completion
1997-01-07 Perforation
1997-01-07 Performed Stimulation
1998-02-12 REWORKED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
1997-01-07 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2006 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2007 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2008 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2009 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2010 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2011 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2012 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2013 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2014 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2015 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2016 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2017 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2018 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 DOMINION ENERGY TRANS INC Produced Fluid 1,371.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2016 DOMINION ENERGY TRANS INC Produced Fluid 338.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2016 Produced Fluid 338 Bbl CENT WASTE TRT FAC NPDES PA0101508
2017 DOMINION ENERGY TRANS INC Produced Fluid 159.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE OH0987034667
2017 DOMINION ENERGY TRANS INC Produced Fluid 906.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2017 DOMINION ENERGY TRANS INC Produced Fluid 6,052.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 DOMINION ENERGY TRANS INC Produced Fluid 5.30 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1091357 Primary Facility 2000-10-31 Routine/Complete Inspection No Violations Noted well ok
1937985 Primary Facility 2010-11-10 Routine/Complete Inspection No Violations Noted DOMINION (NORTH SUMMIT STORAGE FIELD ) WELL IN GOOD CONDITION WITH 2615 PSI. ON IT.
1984628 Primary Facility 2011-05-18 Routine/Complete Inspection No Violations Noted SUMMIT STORAGE FIELD , PSI @ 2170 .
2029805 Primary Facility 2011-11-15 Routine/Complete Inspection No Violations Noted SUMMIT STORAGE FIELD , PRESSURE @ 2418 PSI.
2128722 Primary Facility 2013-01-03 Routine/Complete Inspection No Violations Noted storage well in NS reservoir; 2577 psig measured on 12/26/12; plug set between Chert and Oriskany;
2322088 Primary Facility 2014-10-22 Routine/Complete Inspection No Violations Noted storage well; 2565 psig; withdraw only? verify status; new wh/tj 2014; shut in;
2428755 Primary Facility 2015-11-24 Routine/Complete Inspection No Violations Noted lock out; Side valve C replaced; coil tubing clean out 2015;
2511031 Primary Facility 2016-08-10 Routine/Complete Inspection No Violations Noted Oriskany storage well in North Summit storage pool; plan to clean out well of salt buildup on casing and set downhole plug and pull wellhead to do an internal wellhead and valve inspection; Cleaned out casing with 70 Quality Foam and flow back; Pump 70 Quality foam and clean out to 30' above perfs in the Oriskany and flow back; Spot 15 bbls MSA/Turpene accross perfs; Pull tubing to 1000' above perfs and let soak ; RIH to TD and pump N2 and unload hole while tripping out of hole; flow back well.
2548202 Primary Facility 2016-12-29 Routine/Complete Inspection No Violations Noted Dominion Storage well # UW- 204 with pressure o f 2387 psi. during withdrawal .
2619799 Primary Facility 2017-07-26 Routine/Complete Inspection No Violations Noted Dominion Storage well # UW- 204 with pressure o f 2,347 psi. during compression .
2835730 Primary Facility 2019-02-05 Routine/Complete Inspection No Violations Noted This is a storage well with 1759 psi on it and the annulus is open. The well head casing and valves look ok.
363716 Primary Facility 1987-07-27 Routine/Complete Inspection No Violations Noted WELL IS PLUGGED
378389 Primary Facility 1995-07-21 Routine/Complete Inspection No Violations Noted E&S, ID OK
380349 Primary Facility 1996-04-24 Plugging(Includes Plugged/Mined Through) No Violations Noted CO UW-204/P&A; W/VENT
381124 Primary Facility 1996-10-10 Routine/Complete Inspection No Violations Noted MOVING IN
381668 Primary Facility 1996-11-27 Routine/Complete Inspection No Violations Noted RIG SHUT DOWN
382151 Primary Facility 1997-03-07 Routine/Complete Inspection Violation(s) Noted <2' FRBRD/E&S OK
382284 Primary Facility 1997-03-31 Routine/Complete Inspection No Violations Noted PRE-SOLIDIF INSP/ID/PIT/E&S OK
382313 Primary Facility 1997-04-11 Routine/Complete Inspection No Violations Noted PIT SOLIDIFICATION INSP/OK
382314 Primary Facility 1997-04-28 Routine/Complete Inspection No Violations Noted SOLID PIT BACKFILLED/ID,ES OK
382538 Primary Facility 1996-11-20 Routine/Complete Inspection No Violations Noted WELL BEING REWORKED/UW 204
384790 Primary Facility 1998-03-10 Routine/Complete Inspection No Violations Noted 2740 PSI/ANN OPEN
385306 Primary Facility 1998-07-09 Routine/Complete Inspection No Violations Noted E&S ADEQUATE
387479 Primary Facility 1999-05-19 Routine/Complete Inspection No Violations Noted 2751 PSI; ANN OPEN
917221 Primary Facility 2000-02-17 Routine/Complete Inspection No Violations Noted Recent pipeline excavation has been mulched. Id.tag is missing due to painting of well equip. and needs replacement.
951089 Primary Facility 2000-06-15 Routine/Complete Inspection No Violations Noted 2575 PSI; ANN OPEN

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
382151 108932 03/07/1997 1997-03-07 78.56.9101.4 - Impoundment not; permitted or approved, structurally sound, impermeable, third party protected, 2 ft freeboard, inadequate liner, subbase, slopes, capacity, surface water not diverted, w/in 20 inches of high ground water table Administrative PIT VIOL FRBRD

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
108932 8092 NOV - Notice of Violation Comply/Closed 1998-07-09

For data sources see[8]