X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24425

Well Details

Well ID: 37-051-24425
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Redstone Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149316
Farm/Lease Name: SKOVRAN UNIT 38H
License Status:
Spud Date:
Permit Date: 2011-02-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.936986
Longitude: -79.873261

For data sources see[1][2][3]

Well History

Date Event
2011-02-14 New Permit Application
2011-08-04 Performed Spud Operation
2011-12-21 Drilling Completion
2012-07-26 Perforation
2012-07-26 Performed Stimulation
2016-04-21 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-07-26 2012-07-26 6,987 4,599,553

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00747000
Polyethylene glycol 25322-68-3 60.00 0.01
Dibromoacetonitrile 3252-43-5 5.00 0.00125000
GBW-30 BREAKER Halliburton Energy Services Gel Breaker Carbohydrates 95.00 0.00010000
Hemicellulase enzyme 9012-54-8 15.00 0.00002000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.26
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00335000
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00740000
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00693000
Clean Volume (gals) Carrier/Base Fluid 92.02 100.00
Proppant (lbs) Proppant 7.98 8.73
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-07-26 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 65,354.00 31 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 895,077.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 531,029.00 268 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 435,276.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 336,700.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 287,812.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 254,664.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 221,565.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Produced Fluid 65.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 3.57 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 155.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 7,709.25 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 880.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 89.65 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Produced Fluid 5,395.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 10,073.25 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 1.12 Tons LANDFILL 100592
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 222.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 1.17 Tons LANDFILL 100592
2014 CHEVRON APPALACHIA LLC Produced Fluid 30.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Produced Fluid 25.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,412.75 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 803.75 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 349.52 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 382.25 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Soil Contaminated by Oil 0.06 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 CHEVRON APPALACHIA LLC Produced Fluid 1,210.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 56.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 140.50 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Soil Contaminated by Oil & Gas Related Spills 0.06 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 CHEVRON APPALACHIA LLC Produced Fluid 52.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste 27.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 166.75 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 188.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 30.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 CHEVRON APPALACHIA LLC Produced Fluid 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 240.00 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1969278 Primary Facility 2011-04-29 Routine/Complete Inspection No Violations Noted
1976116 Primary Facility 2011-05-24 Routine/Complete Inspection No Violations Noted
2005115 Primary Facility 2011-09-06 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. MOVED ON (9/3/2011)DRILLING ON AIR TO745'.( 9/6/2011)CEMEMTING WATER PROTECTION CASING, STARTED TO MOVE OVER (9/6/2011).
2009777 Primary Facility 2011-10-08 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 2910', RUNNING COAL PROTECTION CASING TONIGHT AND CEMENTING.
2009779 Primary Facility 2011-10-03 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRIILING ON AIR @ 884' TODAY,EXSPECTING TO (TD) TODAY @ 900'.COAL MINE @ 803' -813'. RUNNING COAL PROTECTION CASING TONIGHT AND CEMENTING.
2025443 Primary Facility 2011-12-01 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, RIGGING UP ON SKOVRAN 38 -H.
2025450 Primary Facility 2011-12-07 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 3419' TODAY.
2092344 Primary Facility 2012-08-15 Routine/Complete Inspection No Violations Noted Site ID sign in place, E&S, permit and PPC plan on site, E&S controls in place and functioning,
2104896 Primary Facility 2012-09-28 Routine/Complete Inspection No Violations Noted Site ID sign up, permit, PPC plan, and E&S plan in tube. All wells fracked, now doing liner removal, E&S up and functioning, wells labeled.
2213578 Primary Facility 2013-10-17 Routine/Complete Inspection No Violations Noted Act 9 sign up, wells labeled. Site mostly reclaimed except for 4 sed traps and channels. Operator made aware of some erosion issues on pad fill slope. Tanks in containment, no leaks observed.
2274776 Primary Facility 2014-05-29 Routine/Complete Inspection No Violations Noted On 5/29/2014, the Department conducted an inspection of Chevron Appalachia’s Skovran Unit 37, 38, 39, 40 H well site in Redstone Twp., Fayette County.
2462120 Primary Facility 2016-02-25 Routine/Partial Inspection No Violations Noted
2564701 Primary Facility 2017-02-23 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. A slide had previously occurred on the site and had been repaired (see photographs). Portions of the site appeared to have been recently seeded and mulched. There were no signs of erosion observed. The equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2658212 Primary Facility 2017-10-26 Site Restoration No Violations Noted A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and met and exceeded uniform 70% vegetative cover. There were no signs or erosion observed. There were no violations observed. The site meets the requirements for permit termination. The NOT is approved.
2839247 Primary Facility 2019-02-13 Routine/Complete Inspection No Violations Noted This well is tagged and temporarily shut in. The well head casing, piping, production set equipment, containment dike and fluid collection tank look ok.

For data sources see[9]