If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-051-24438 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.050308,"lon":-79.573314,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Fayette | |
Municipality: Bullskin Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 147988 | |
Farm/Lease Name: CONNELLSVILLE SPORTSMENS ASSOC UNIT 7H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-04-08 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.050308 | |
Longitude: -79.573314 |
Date | Event |
---|---|
2011-04-08 | New Permit Application |
2011-07-27 | Performed Spud Operation |
2012-01-20 | Drilling Completion |
2012-06-27 | Perforation |
2012-06-27 | Performed Stimulation |
2016-04-12 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-06-27 | 2012-06-27 | 6,000 | 2,753,302 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | GBW-30 BREAKER | Halliburton Energy Services | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00001000 | |
Carbohydrates | 95.00 | 0.00006000 | ||||||
EC6673W | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00689000 | ||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.27 | |||
Clean Volume (gals) | Carrier/Base Fluid | 90.52 | 100.00 | |||||
Biocide EC 6116A | Nalco | Biocide | Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00742000 | |||||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00124000 | |||||
Proppant (lbs) | Proppant | 9.48 | 10.56 | |||||
ASP 900 | Nalco | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | |||
EC6486A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00736000 | ||
WG-36 GELLING AGENT | Halliburton Energy Services | Water Viscosifier | Guar gum | 9000-30-0 | 100.00 | 0.00194000 | ||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.03 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-06-27 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 164,281.00 | 92 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 438,725.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 284,453.00 | 287 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 221,250.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 176,783.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 151,690.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 110,835.00 | 304 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 127,586.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 155.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 3,300.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2011 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 12,050.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 18,225.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 19,454.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 50.11 Tons | LANDFILL | 100419 |
2012 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 11,887.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 0.86 Tons | LANDFILL | 100172 |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 2,029.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 64.85 Tons | LANDFILL | 073 114 654 |
2013 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,467.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHEVRON APPALACHIA LLC | Produced Fluid | 230.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 60.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 596.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHEVRON APPALACHIA LLC | Produced Fluid | 360.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 328.52 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 0.29 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 265.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 223.50 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 56.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 42.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | CHEVRON APPALACHIA LLC | Other Oil & Gas Wastes | 10.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 100.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1965698 | Primary Facility | 2011-04-11 | Routine/Complete Inspection | No Violations Noted | |
1969288 | Primary Facility | 2011-04-29 | Routine/Complete Inspection | No Violations Noted | |
1980964 | Primary Facility | 2011-06-13 | Routine/Complete Inspection | No Violations Noted | |
1991498 | Primary Facility | 2011-07-28 | Routine/Complete Inspection | No Violations Noted | |
2005059 | Primary Facility | 2011-07-29 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. CEMENTING 24" CONDUCTOR PIPE @ 152'. |
2005074 | Primary Facility | 2011-08-24 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS,E&S & PITS LOOK IN GOOD CONDITION.CEMENTING COAL PROTECTION CASING TONIGHT @ 860'. |
2025593 | Primary Facility | 2011-09-01 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, DRILLING ON AIR @ 1139' (TD), RUNNING INTERMEDIATE CASING AND CEMENTING TONIGHT. |
2038446 | Primary Facility | 2012-01-04 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS,SKIDDING OVER TO CONNESVILLE SPORTMAN CLUB # 8 - H TODAY ,RIGGING -UP. |
2038447 | Primary Facility | 2012-01-14 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, PATTERSON RIG # 56 DRILLING ON FLUID @ 6000' (KOP) TODAY. |
2038454 | Primary Facility | 2012-01-17 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, PATTERSON RIG # 56 DRILLING ON FLUID @ 8509' TODAY. |
2038455 | Primary Facility | 2012-01-20 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, PATTERSON RIG # 56 DRILLING ON FLUID @ 8946' TODAY ( LANDING IN MARCELLUS ). |
2038509 | Primary Facility | 2012-01-23 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS,PATTERSON RIG # 56 TD ON FLUID @11,922',RUNNING PROD. CASING AND CEMENTING TONIGHT. |
2102169 | Primary Facility | 2012-09-25 | Incident- Response to Accident or Event | In Compliance with Policy | Reuse water spill on pad site, approx. 50 gallons, operator handled spill in accordance with the Department's current spill policy. |
2117215 | Primary Facility | 2012-11-20 | Site Restoration | No Violations Noted | Restoration extension requested by operator, E&S in place and funtioning, no accelerated erosion observed, extension approved to 11/1/13. |
2479069 | Primary Facility | 2016-04-27 | Routine/Complete Inspection | No Violations Noted |
On 04/27/16 at approximately 0700 hours I conducted a routine complete inspection of the site. The Act 9 sign was in place and all required documents were present in the mail box. The site was well vegetated and the wells appeared to be in good condition. There were no violations observed at the time of inspection. |
2585204 | Primary Facility | 2017-04-20 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2684868 | Primary Facility | 2018-01-22 | Routine/Complete Inspection | No Violations Noted | Well appears to be in production. Well tender on site during inspection. Two brine tanks on site. |
2701521 | Primary Facility | 2018-03-06 | Administrative/File Review | No Violations Noted | Access blocked by locked gate. Will return for full inspection after meeting with operator. |
2705932 | Primary Facility | 2018-03-15 | Routine/Partial Inspection | No Violations Noted | Routine partial inspection conducted to ensure site ID sign has been installed correctly. At time of inspection site ID sign is present and installed as per 78a55(i)4 regulations. |
2707407 | Primary Facility | 2018-03-20 | Routine/Complete Inspection | No Violations Noted | Well properly equipped for production and tagged. Location inspection shows no apparent violations. NOVIO |
2824607 | Primary Facility | 2019-01-10 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
For data sources see[9]