37-051-24482

Well Details

Well ID: 37-051-24482
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Jefferson Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 144934
Farm/Lease Name: ROSUL UNIT 4H
License Status:
Spud Date:
Permit Date: 2011-11-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.087656
Longitude: -79.792569

For data sources see[1][2][3]

Well History

Date Event
2011-11-14 New Permit Application
2013-03-06 New Permit Application
2013-06-04 Performed Spud Operation
2013-12-07 Drilling Completion
2014-06-22 Perforation
2014-06-22 Performed Stimulation
2016-02-11 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-06-22 2014-07-15 8,148 3,213,000

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 A264 Schlumberger Iron Control Prop-2-yn-1-ol 107-19-7 10 0.00001002 0
Methanol 67-56-1 40 0.00004009 0
Aliphatic alcohols, ethoxylayed #1 Proprietary 30 0.00003007 0
Aliphatic acids Proprietary 30 0.00003007 0
7.5% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 8 0.0098823 0
B466 Schlumberger Friction Reducer Ammonium Acetate 631-61-8 6 0.00066857 0
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.00334284 0
Alcohol Ethoxylates Proprietary 5 0.00055714 0
Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 90.4861 0
EC6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5 0.00012638 0
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00075828 0
Polyethylene Glycol 25322-68-3 60 0.00151656 0
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00040363 0
J580 Schlumberger Gelling Agent Carboydrate polymer Proprietary 100 0.0187846 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 9.326 0
EC6673W Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00077733 0
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00080357 0
J134 Schlumberger Gel Breaker Hemicellulase Enzyme 9012-54-8 100 0.00099928 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-06-22 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 240,712.00 69 0.00 0 15.00 69
2015 CHEVRON APPALACHIA LLC 586,982.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 326,805.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 186,458.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 158,030.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 138,001.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drill Cuttings 0.17 Tons LANDFILL 100419
2013 CHEVRON APPALACHIA LLC Drill Cuttings 1,627.03 Tons LANDFILL 100592
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,549.30 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 888.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 9,533.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 30.57 Tons LANDFILL 100592
2014 CHEVRON APPALACHIA LLC Drill Cuttings 1.07 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Produced Fluid 15.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 8.67 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 4,418.75 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 2,408.75 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 28.40 Tons LANDFILL 76-00-08
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 3.95 Tons LANDFILL 100663
2015 CHEVRON APPALACHIA LLC Produced Fluid 280.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 37.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 69.68 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565
2015 CHEVRON APPALACHIA LLC Produced Fluid 7,392.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 1,012.80 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 1,465.51 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 196.25 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 3,609.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 427.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 82.96 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 163.68 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste 26.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 220.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 55.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 440.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 78.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 638.87 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 32.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2113327 Primary Facility 2012-08-27 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, LOCATION ARE NOT BEING BUILT.
2145771 Primary Facility 2013-03-05 Routine/Complete Inspection No Violations Noted Pre-OP Inspection completed today for wells 1 to 4 H. E&S in place and functioning. work being done on pad. Sign up, plans and permits in box.
2178370 Primary Facility 2013-06-05 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, ROCKY MOUNTAIN DRILLING CONDUCTOR IN @ 40' (6/5/2013).
2204751 Primary Facility 2013-08-20 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 2029' (TD).RUNNING INTERMEDIATE CASING AND CEMENTING TONIGHT (8/17/2013).
2204869 Primary Facility 2013-08-14 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE DRILLING ON AIR @ 562' (TD). RUNNING 2ND WATER PROTECTION CASING AND CEMENTING TODAY.
2204878 Primary Facility 2013-08-12 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS ,KEANE DRILLING ON AIR @ 489'(TD). RUNNING COAL PROTECTION CASING AND CEMENTING TODAY.
2204885 Primary Facility 2013-08-09 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS ,KEANE DRILLING ON AIR @ 262' (TD). RUNNING 1ST WATER PROTECTION CASING AND CEMENTING TONIGHT.
2205686 Primary Facility 2013-09-17 Routine/Complete Inspection No Violations Noted Act 9 sign up, permits and plans in box. Patterson Rig 334 drilling on site currently. No E&S issues.
2230696 Primary Facility 2013-12-04 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 11,045' (TD).RUNNING 51/2" PROD. CASING AND CEMENTING TONIGHT (12/3/2013).
2230701 Primary Facility 2013-11-12 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 334 MOVING ON TO ROSUL # 4 -H TODAY.
2243455 Primary Facility 2014-01-31 Routine/Complete Inspection No Violations Noted On 1/31/2014, the Department conducted an Inspection at the Chevron Appalachia’s Rosul Well Units 1, 2, 3, and 4H site in Washington Twp., Fayette County.
2253421 Primary Facility 2014-02-04 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, STAGE 3 - 1-MILLION OPEN TOP TANKS AND FILLING PRYOR TO FRAC JOB.
2262845 Primary Facility 2014-03-25 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, ON STAND DOWN UNTIL FURTHER NOTICE. FILLING 3 -OPEN FRAC TANKS AT PRESENT TIME ON LOCATION.
2416828 Primary Facility 2015-10-19 Complaint Inspection No Violations Noted 4 wells drilled and equipped for production.
2467309 Primary Facility 2016-02-18 Routine/Complete Inspection No Violations Noted On 02/18/16 at approximately 1100 hours I conducted a complaint inspection of the Rosul Unit. The Act 9 sign was in place and all required documents were present in the mail box.

The site was well vegetated and there were no signs of erosion and sedimentation. The wells appeared to be in good condition and there was no evidence of a release from the site. There were no diesel fuel storage vessels on the site.

2523583 Primary Facility 2016-09-29 Routine/Complete Inspection No Violations Noted HORIZONTAL MARCELLUS, Well appears to be producing natural gas.
2598817 Primary Facility 2017-05-09 Routine/Complete Inspection No Violations Noted An inspection was conducted in response to a well site restoration report submitted by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was found to be restored and well vegetated. There were no violations observed at the time of inspection.
2661192 Primary Facility 2017-11-15 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[9]

References