X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24486

Well Details

Well ID: 37-051-24486
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Redstone Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148748
Farm/Lease Name: LEE UNIT 14H
License Status:
Spud Date:
Permit Date: 2011-12-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.003889
Longitude: -79.814303

For data sources see[1][2][3]

Well History

Date Event
2011-12-14 New Permit Application
2011-12-30 Performed Spud Operation
2012-03-27 Drilling Completion
2012-08-07 Perforation
2012-08-07 Performed Stimulation
2016-04-25 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-08-07 2012-08-07 7,504 2,968,741

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00625000
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00718000
Dibromoacetonitrile 3252-43-5 5.00 0.00120000
Polyethylene glycol 25322-68-3 60.00 0.01
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.29
Clean Volume (gals) Carrier/Base Fluid 91.17 100.00
Proppant (lbs) Proppant 8.29 9.11
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00416000
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00707000
GBW-30 BREAKER Halliburton Energy Services Gel Breaker Carbohydrates 95.00 0.00171000
Hemicellulase enzyme 9012-54-8 15.00 0.00027000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-08-07 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 430,920.00 334 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 332,196.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 217,379.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 170,918.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 135,378.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 117,041.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 104,233.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 1,430.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 2.31 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,910.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 33,624.50 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 8,255.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,920.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 207.31 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Produced Fluid 2,901.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,280.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Drill Cuttings 3.41 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,733.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Drilling Fluid Waste 100.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 40.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 710.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 160.01 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 425.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 82.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 105.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 54.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 278.50 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 221.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 284.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 295.00 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2038587 Primary Facility 2012-01-26 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS RIG # 7 DRILLING ON AIR @ 126' ,RUNNING WATER PROTECTION CASING AND CEMENTING TONIGHT.
2038591 Primary Facility 2012-01-29 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLAND RIG # 7 DRILLING ON AIR @ 557' TODAY. RAN COAL PROTECTION CASING @ 551' (1/29/2012).
2055128 Primary Facility 2012-03-05 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 7 RIGGING DOWN THIS WEEK. RELOCATING ON HARTLEY #9 - H .
2055131 Primary Facility 2012-03-01 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 7462' TODAY. MUDDING -UP AND CAPPING.
2055132 Primary Facility 2012-02-27 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 6675' TODAY.
2055135 Primary Facility 2012-02-21 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 2653' TODAY (TD). RUNNING INTERMEDIATE CASING AND CEMENTING TODAY.
2055138 Primary Facility 2012-02-15 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 555' TODAY (TD).RUNNING COAL PROTECTION CASING AND CEMENTING TODAY.
2055141 Primary Facility 2012-02-15 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 423' (TD). RUNNING WATER PROTECTION CASING AND CEMENTING TODAY.
2055142 Primary Facility 2012-02-14 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 7 MOVING ON TODAY.
2055143 Primary Facility 2012-02-10 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON FLUID @ 8314' TODAY.
2066536 Primary Facility 2012-03-21 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, CROWN # 8 READY TO START DRILLING ON (LEE 14 - H ) @ 7636' (KOP).
2066539 Primary Facility 2012-03-29 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,CROWN # 8 DRILLING ON FLUID @ 12,397' (TD). RUNNING 51/2" PROD. CASING AND CEMENTING TONIGHT.
2101505 Primary Facility 2012-09-21 Incident- Response to Accident or Event In Compliance with Policy One eigth gallon of flow back water spilled onto ground. Immediately cleaned up and placed into container on site to be disposed of.
2121616 Primary Facility 2012-12-06 Routine/Complete Inspection No Violations Noted Site ID sign in place, PPC, permits, and E&S plan in box. Site stable, wells labeled, in completion phase.
2129497 Primary Facility 2013-01-11 Administrative/File Review In Compliance with Policy Operator self reported a small spill on location. Three foot diameter area of gravel was stained. Operator handled spill incident in compliance with current Department spill policy.
2139569 Primary Facility 2013-02-15 Administrative/File Review In Compliance with Policy Small spill of approximately 1 gallon of methanol on pad. Operator cleaned up and reported spill in compliance with current Department spill policy.
2181041 Primary Facility 2013-07-03 Site Restoration No Violations Noted Area reclaimed except for diversion channel and one sed trap. Landowner wants slope regraded which will cause additional earth disturbance so sed traps are still needed. Complaint wants trap removed claiming mosquitos population has increased because of the trap. Department sugested over the counter chemical mosquito control or bat boxes and told operator to contact the West Nile program for guidance.
2185638 Primary Facility 2013-07-23 Site Restoration No Violations Noted Site restoration date extension requested by operator. Site stable and mostly reclaimed. Some work needed to be done at request of landowner. Extension approved to 7/8/14.
2353237 Primary Facility 2015-03-19 Site Restoration No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be ins ound condition. Site had been regraded and the vegetative cover met the 70% uniform coverage criteria. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2372795 Primary Facility 2015-05-19 Site Restoration No Violations Noted
2597218 Primary Facility 2017-05-19 Routine/Complete Inspection No Violations Noted On 05/18 and 05/19 Chevron had Civil and Environmental Consultants (CEC) perform soil testing and vegetative analysis in response to a Complainant alleging soil compaction had occurred on the site. The Complainant had hired a consultant to conduct an investigation to look for evidence of compaction. The Department and Chevron are in possession of the report completed by the consultant post investigation.


The following CEC Representatives conducted the investigation:


Joe Isaac, CEC Project Manager and Botanist John K. Buck, CEC CPSS Project Manager and Soil Scientist Ryan Duke, CEC Civil Engineer


The following Chevron representatives were present at the site at varying times during the two days CEC conducted their investigation:


Todd Radolec, Chevron PE Civil Team Lead Angela Layton, Chevron PE Facilities Engineering Rodney Frazee, Chevron Surface Land Representative Nick Staffieri, Chevron Regulatory Compliance Team Lead Bernard A. Lambie, Chevron Regulatory Compliance Team Member


The Complainant

2626508 Primary Facility 2017-08-03 Routine/Partial Inspection No Violations Noted On 06/15/17 Chevron Appalachia LLC submitted a request for extension of the ESCGP. As of 07/31/17 the extension request had not been approved and the permit expired.

On 08/03/17 I conducted a routine partial inspection of the site. The Act 9 sign was in place and all required documents were present at the site. The portion of the site below the well pad appeared to have been recently mowed (see photographs). The portion above the well pad had not been mowed. The site was well vegetated and there were no signs of erosion found at the time of inspection.

An unfilled test pit from the Rettew soil investigation was observed below the well pad (see photographs). The pit contained water at the time of inspection.

A wet location was observed on the lower portion of the site (see photographs). The wet area appeared to be located in a swale. The area appeared to exhibit wetland vegetation. A shallow depression with standing water was observed in this location. The depression appeared to be caused by equipment us

2760069 Primary Facility 2018-08-01 Routine/Partial Inspection No Violations Noted On 08/01/18 at approximately 1345 hours I conducted a routine partial inspection of the site. The Act 9 sign was in place and all required documents were present at the site. Chevron had recently installed a french drain type system below the well pad to alleviate a wet spot in the field. Accelerated erosion and poor vegetative cover were observed in the recently disturbed area (see photographs). It is recommended that the erosion be repaired and additional seed and mulch be applied. Several small pieces of scrap black pipe were observed. It is recommended the scrap material be removed.

For data sources see[9]