X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24487

Well Details

Well ID: 37-051-24487
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Menallen Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148607
Farm/Lease Name: JACKSON FARMS UNIT 41H
License Status:
Spud Date:
Permit Date: 2012-01-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.967181
Longitude: -79.809758

For data sources see[1][2][3]

Well History

Date Event
2012-01-11 New Permit Application
2012-02-07 Performed Spud Operation
2012-06-03 Drilling Completion
2012-12-14 Perforation
2012-12-14 Performed Stimulation
2016-04-12 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-12-14 2012-12-14 8,432 6,228,678

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 GBL Clearwater International Gel Breaker Ethylene glycol 107-21-1 60.00 0.00004000
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00696000
Polyethylene glycol 25322-68-3 60.00 0.01
Dibromoacetonitrile 3252-43-5 5.00 0.00116000
Scale Inhibitor A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00688000
Proppant (lbs) Proppant 8.11 8.90
CMHPG Ashland Water Viscosifier Carboxymethylhydroxyporoyl guar blend 100.00 0.00247000
Iron Control A Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00694000
Clean Volume (gals) Carrier/Base Fluid 91.89 100.00
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.26
Unislik ST 50 CESI Chemical Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-12-14 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 1,339,057.00 306 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 1,140,989.00 365 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 811,852.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 599,809.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 486,815.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 415,626.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 364,793.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 2,503.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 1,218.32 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 598.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 36.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 6,617.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 406.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 79.69 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Produced Fluid 5,335.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,229.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 275.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 335.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 14,746.80 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Drill Cuttings 4.20 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 28.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 29.33 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,723.33 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 842.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 335.02 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 431.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 3,080.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 110.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 167.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 37.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 115.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 216.67 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 428.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 38.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 406.66 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2054980 Primary Facility 2012-03-19 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 8330' (TD). RUNNING 2 - CEMENT PLUGS BACK TO (KOP - 7330').
2054981 Primary Facility 2012-03-10 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 2652' (TD). RUNNING INTERMEDIATE CASING AND CEMENTING TODAY.
2054982 Primary Facility 2012-03-04 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 570' (TD). RUNNING COAL PROTECTION CASING AND CEMENTING TODAY.
2054983 Primary Facility 2012-03-03 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 385' (TD). RUNNING WATER PROTECTION CASING AND CEMENTING TODAY.
2054984 Primary Facility 2012-02-27 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLAND # 9 MOVING ONTO LOCATION THIS WEEK.
2079829 Primary Facility 2012-06-01 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 334 DRILLING ON FLUID @ 13,603' (TD). RUNNING 51/2" PROD. CASING AND CEMENTING TONIGHT (6/3/2012).
2079845 Primary Facility 2012-05-25 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,PATTERSON # 334 MOVING ON THE WEEK OF (5./26/2012).
2088669 Primary Facility 2012-07-27 Routine/Complete Inspection No Violations Noted Site ID sign up with all numbers, E&S plan and well permit in box, Wells drilled but not in production. Temporary stabilization of slopes needs dressed up some, operator notified.
2101398 Primary Facility 2012-09-20 Routine/Complete Inspection No Violations Noted Site ID up, PPC & E&S plan and permits in tube, E&S controls in place and working, pits have over 2 feet freeboard, wells labeled
2120638 Primary Facility 2012-02-05 Routine/Complete Inspection No Violations Noted Site being preparred for stimulation, E&S ok, soil stockpile stable, pits had 2 foot freeboard.
2127886 Primary Facility 2013-01-07 Administrative/File Review In Compliance with Policy Operator self reported a spill of approximately 3 to 5 gallons of diesel fuel on the lease road. Operator cleaned up the affected areas and in complaince with the current Departments spill policy.
2129298 Primary Facility 2013-01-09 Routine/Complete Inspection No Violations Noted Sign up and PPC, permits and E&S in box. E&S in place and functioning, all impoundments had 2 foot free board, fracking completed.
2130208 Primary Facility 2013-01-15 Administrative/File Review In Compliance with Policy Operator self reported spill of 40 barrels of water. All material spilled was contained on secondary containment. Operator cleaned up water and re-used it in the fracing process. Operator performed clean up in compliance with the current Departments spill policy.
2185754 Primary Facility 2013-07-24 Site Restoration No Violations Noted Area being reclaimed. Impoundment reclaimed, wells hooked up, pit contents and liners removed, area stable. Extension approved until 5/30/14.
2225139 Primary Facility 2013-11-26 Routine/Complete Inspection No Violations Noted On 11/26/2013, the Department conducted an inspection of the Chevron Appalachia’s Jackson Farms 41, 42, and 43H unit wells in Menallen Twp., Fayette County.
2301620 Primary Facility 2014-09-04 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The well apparatus and brine tanks appear to be in sound working condition.
2357529 Primary Facility 2015-04-01 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appearedx to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2571288 Primary Facility 2017-03-14 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was covered in a light dusting of snow, but appeared to be well vegetated. There were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2756261 Primary Facility 2018-07-26 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[9]

References