If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-059-26230 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.987314,"lon":-80.186447,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Washington Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 145801 | |
Farm/Lease Name: SHIPMAN 590584 | |
License Status: | |
Spud Date: | |
Permit Date: 2013-07-08 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 39.987314 | |
Longitude: -80.186447 |
Date | Event |
---|---|
2013-07-08 | New Permit Application |
2013-08-06 | New Permit Application |
2014-08-27 | Permit Renewal Application |
2015-06-18 | Performed Spud Operation |
2015-08-27 | New Permit Application |
2015-10-26 | Drilling Completion |
2015-11-07 | Perforation |
2015-11-08 | Performed Stimulation |
2016-04-27 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-10-31 | 2015-11-20 | 7,386 | 13,593,100 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FE-100L | FTS International | Iron control | Citric acid | 77-92-9 | 55 | 0.00005533 | 69.85 |
CI-150 | FTS International | Acid corrosion inhibitor | Organic amine resin salt | Proprietary | 30 | 0.00013154 | 166.057 | |
Aromatic aldehyde | Proprietary | 10 | 0.00004385 | 55.352 | ||||
Ethylene glycol | 107-21-1 | 30 | 0.00013154 | 166.057 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00004385 | 55.352 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00004385 | 55.352 | ||||
Isopropanol | 67-63-0 | 30 | 0.00013154 | 166.057 | ||||
FRW-900 | FTS International | Friction reducer | Alkyl alcohol | Proprietary | 10 | 0.00609552 | 7695.03 | |
Oxyalkylated alcohol A | Proprietary | 5 | 0.00304776 | 3847.52 | ||||
Hydrotreated light distillate | 64742-47-8 | 30 | 0.0182866 | 23085.1 | ||||
CS-500-SI | FTS International | Scale inhibitor | Ethylene glycol | 107-21-1 | 10 | 0.00244929 | 3092.01 | |
Water | FTS International | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 89.8558 | 113,435,000.0 | |
NE-100 | FTS International | Non-emulsifier | Dodecylbenzenesulfonic acid | 27176-87-0 | 5 | 0.00002061 | 26.024 | |
2-Butoxyethanol | 111-76-2 | 10 | 0.00004123 | 52.048 | ||||
2-Propanol | 67-63-0 | 10 | 0.00004123 | 52.048 | ||||
Sand (Proppant) | FTS International | Proppant | Silica Substrate | 14808-60-7 | 100 | 9.72638 | 12,278,700.0 | |
Hydrochloric Acid (15%) | FTS International | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0353302 | 44601.1 | |
MC MX 437-5 | Multi-Chem Group LLC | Calcium nitrate solution | Calcium nitrate | 10124-37-5 | 60 | 0.0575558 | 72658.9 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-11-08 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | EQT PROD CO | 209,539.00 | 18 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 2,875,800.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 1,736,868.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 1,288,194.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 933,150.00 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | EQT PROD CO | Fracturing Fluid Waste | 16.12 Tons | LANDFILL | SWF 1032-WV0109 |
2015 | EQT PROD CO | Drilling Fluid Waste | 5,418.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Fracturing Fluid Waste | 106.70 Tons | LANDFILL | 100277 |
2015 | EQT PROD CO | Drill Cuttings | 1,629.64 Tons | LANDFILL | 100419 |
2015 | EQT PROD CO | Produced Fluid | 10,563.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Fracing Fluid Waste | 9,144.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 1,490.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Drilling Fluid Waste | 330.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 1,110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 840.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 530.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2016 | EQT PROD CO | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2016 | EQT PROD CO | Produced Fluid | 294.00 Bbl | INJECTION DISPOSAL WELL | 34-167-2-9543 |
2016 | EQT PROD CO | Synthetic Liner Materials | 7.17 Tons | LANDFILL | SWF 1032-WV0109 |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 25.13 Tons | LANDFILL | 100419 |
2016 | EQT PROD CO | Produced Fluid | 47,153.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | EQT PROD CO | Produced Fluid | 1,160.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 195.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 65.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 65.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017 | EQT PROD CO | Produced Fluid | 4,270.00 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 758.78 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 883.68 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 188.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 664.26 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 55.58 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 52.58 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 32.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 634.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 346.60 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 2,846.35 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 1.93 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 148.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2202894 | Primary Facility | 2013-09-04 | Routine/Complete Inspection | No Violations Noted | On 9/4/2013, I performed an inspection of EQT Shipman well pad site. The site is located in Washington Twp., Greene County. The inspection was performed due to a request by the Operator for a Pre-operational inspection. |
2213079 | Primary Facility | 2013-10-08 | Drilling/Alteration | No Violations Noted | CONDUCTOR SET. RIG ON SITE WILL SKID AND COMMENCE DRILLING OF TOP HOLE. |
2231589 | Primary Facility | 2013-12-16 | Routine/Complete Inspection | No Violations Noted | On 12/16/2013, I performed an inspection of EQT's Shipman well pad site. The site is located in Washington Twp., Greene County. The inspection was performed as a routine inspection during drilling. |
2376715 | Primary Facility | 2015-06-04 | Routine/Complete Inspection | No Violations Noted | On 6/4/15, I inspected the Shipman Pad as a routine inspection and made the following observations: |
2419680 | Primary Facility | 2015-10-09 | Drilling/Alteration | No Violations Noted | Horizontal Genesee, Pioneer moving on to location today (10/9/2015). |
2419685 | Primary Facility | 2015-10-19 | Drilling/Alteration | No Violations Noted | Horizontal Genesee, Pioneer drilling on fluid @ 14,404 ' today (10/19/2015). Landing Point @ 8503' .E&S control look good. |
2809921 | Primary Facility | 2018-11-26 | Incident- Response to Accident or Event | In Compliance with Policy | On 11/22/18 at approximately 0952 David Guidas of EQT reported an impaired water spill on the Shipman well pad.
On 11/26/18 at approximately 1200 hours I conducted an incident response inspection. I spoke via phone with David Guidas who indicated 10 gallons of produced fluid was spilled when a line containing impaired water was removed from a frac tank. Due to teardown activities at the site the secondary containment had a hole that allowed the fluid to reach the ground surface. The spill was remediated by SPSI. The spill has been addressed in compliance with DEP spill policy. |
For data sources see[9]