X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-063-37021

Well Details

Well ID: 37-063-37021
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: Green Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 147890
Farm/Lease Name: BUTERBAUGH 10H
License Status:
Spud Date: 2011-09-28
Permit Date: 2011-01-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.694525
Longitude: -78.915103

For data sources see[1][2][3]

Well History

Date Event
2011-01-10 New Permit Application
2011-09-28 Performed Spud Operation
2011-12-20 Drilling Completion
2012-08-29 Perforation
2013-01-15 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-08-29 2012-08-29 7,087 2,242,248

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Clean Volume (gals) Carrier/Base Fluid 90.35 100.00
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.33
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00704000
Proppant (lbs) Proppant 9.65 10.77
Biocide EC 6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5.00 0.00119000
Polyethylene glycol 25322-68-3 60.00 0.01
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00714000
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00169000
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00660000
GBW-30 BREAKER Halliburton Energy Services Gel Breaker Hemicellulase enzyme 9012-54-8 15.00 0.00008000
Carbohydrates 95.00 0.00050000
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 26,624.00 31 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 210,011.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 138,951.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 97,735.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 82,823.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 69,271.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 56,304.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 50,242.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 220.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 1.26 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 6,031.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,062.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 3,810.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 26.85 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Produced Fluid 6,022.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 7,449.70 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 120.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 2,077.34 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,231.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 735.70 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 713.34 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 4,656.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 71.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 258.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 37.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 275.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 113.33 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 72.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 470.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 35.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 643.33 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2007143 Primary Facility 2011-09-29 Drilling/Alteration No Violations Noted
2010697 Primary Facility 2011-10-05 Routine/Complete Inspection No Violations Noted During This inspection, well sign, Es plan, and PPC plan present. Rep Dan Hamlett onsite. Recommend operator place ESCGP-1 in box with ES plan, as unable to locate at time of inspection. It is also recommended that ES plan, ESCGP-1, and site id signs be updated accordingly. Access road stable and adequately rocked. Pioneer drilling Rig 60 onsite rigging up, not yet drilling. Pad beneath rig lined with secondary containment, as well as all areas containing onsite liquids. One lined pit located onsite containing rainwater, adequate freeboard although dept recommends emptying prior to drilling. Bmp¿s installed and functioning according to plan; no accelerated erosion or sedimentation issues noted. No violations noted during this inspections.
2011036 Primary Facility 2011-10-14 Drilling/Alteration No Violations Noted
2012932 Primary Facility 2011-10-20 Drilling/Alteration No Violations Noted
2020932 Primary Facility 2011-11-18 Routine/Complete Inspection No Violations Noted Site visit was follow-up to 11-9-11 incident inspection to mud based oil spill.
2023888 Primary Facility 2011-11-22 Drilling/Alteration No Violations Noted
2025583 Primary Facility 2011-12-09 Drilling/Alteration No Violations Noted
2027677 Primary Facility 2011-12-15 Drilling/Alteration No Violations Noted
2034315 Primary Facility 2012-01-11 Routine/Complete Inspection No Violations Noted During this inspection, Site Id sign located at access road entrance. ES plan, PPC and ESCGP-1 located onsite. Pioneer Rig 60 onsite actively drilling 9H , 8H previously drilled and top hole drilled on 10H. Pad lined with secondary containment, which appears structurally sound. Temporary bmp's installed/functioning as per ES plan. No accelerated erosion or sedimentation issue noted. Access road stable. Site gated and protected by security guard. No violations noted during this inspection. Although as noted previously, once containment is removed a follow up inspection will be conducted to evaluate what/if any residual impact resulted from 11-18-11 release. Operator shall continue to closely monitor and maintain all bmp's until final permanent site restoration is achieved.
2037068 Primary Facility 2012-01-24 Routine/Complete Inspection No Violations Noted During this inspection, Site Id sign located at access road entrance. ES plan, PPC and ESCGP-1 located onsite. Pioneer Rig 60 onsite actively drilling 9H (Inspt ID#2037025), 8H previously drilled and top hole drilled on 10H.
2045579 Primary Facility 2012-02-23 Routine/Complete Inspection No Violations Noted Inspection result of follow up to Incident reported on this multi-well pad. Reported incident notification follow up response addressed in INSPT ID #2045561 for API 37-063-37020.
2045631 Primary Facility 2012-02-23 Follow-up Inspection No Violations Noted Site visit was follow-up to 11-9-11 incident.
2069245 Primary Facility 2012-05-03 Routine/Complete Inspection No Violations Noted Inspection result of follow up to incident that occurred on 4/18/12 on Buterbaugh 8H (Inspection ID #2061749), reported release of 3-5 bbl of freshwater/friction reducer (residual only) combination onto and outside of containment. (Follow up inspection ID #2069240)
2087299 Primary Facility 2012-07-19 Routine/Complete Inspection No Violations Noted At the time of this inspection, Well Id sign, ES plan, ESCGP-1, PPC plan present.
2100858 Primary Facility 2012-09-13 Routine/Complete Inspection No Violations Noted At the time of this inspection, Well Id sign, ES plan, ESCGP-1, PPC plan present. Total Depth 12/20/11.
2109193 Primary Facility 2012-10-15 Routine/Complete Inspection No Violations Noted nspection result of request for restoration extension. Department received a request for restoration extension on October 4, 2012 (see attached) via email. As per regulation the current (9 month) restoration Deadline is October 26, 2012, based on completion of drilling of last well, on multi well pad, of 1/26/12. At the time of today's inspection, site ID sign, ES plan, ESCGP-1, permit, and PPC plan located onsite. Site monitored by 24-hr security. Wells drilled not yet in production. Site has been temporally stabilized with bmp's and/or rock. No accelerated erosion or sedimentation concerns noted. One below grade lined drill pit onsite. During this inspection Waste Management (independent contractor) and Chevron personnel were actively removing contents (liquid and cuttings) from pit via vac truck. Liner appears structurally sound and freeboard level maintained. No industrial waste concerns were noted at the time of this inspection. It appears that water and liner have been removed from freshwater impoundment. No viols. Restr ext granted
2139085 Primary Facility 2013-02-06 Routine/Complete Inspection No Violations Noted Inspection result of release of hydraulic fluid as noted on Inspection ID # 2137909 for Buterbaugh 9H.
2171115 Primary Facility 2013-05-30 Routine/Complete Inspection No Violations Noted
2195098 Primary Facility 2013-07-24 Routine/Complete Inspection No Violations Noted Multi-well pad. Marcellus. Site ID sign present, in compliance with Act 9 standards.
2207197 Primary Facility 2013-08-27 Routine/Complete Inspection No Violations Noted Multi-well pad. Marcellus.Site ID sign present, in compliance with Act 9 standards.Chevron representative Curtis Small on-site.At time of inspection, 10H drilled, but not producing. 8H, 9H also drilled, but not producing.Opr rep currently putting in line to prep wells for production.According to records, date of TD for 10H was 12/20/2011.Well tag present, legible.
2227715 Primary Facility 2013-12-05 Routine/Complete Inspection No Violations Noted Legibility of well tag compromised.Appears work recently performed on wellheads/prod equipment due to earth disturbance surrounding these areas.TD date for 10H was 12/20/2011.Three brine tanks on-site, all sound.Located w/in lined, steel containment unit with accumulation/ice observed.Dept recommends Opr properly empty and dispose of accum as per current regs.Dept previously granted restoration extension until 4/26/14.Site temp stabilized with mod veg growth observed. AR stable.Dept rec'ds Opr continue to monitor/maintain well site to ensure final restoration is achieved.At 0915, contacted Chevron rep C. Small via phone to discuss recent earth disturbance activities referenced above and well tag concerns.Mr. Small stated that lines were buried last week in order to vent annuli to prod tanks as annuli previously vented to temporary tanks. Dept rec'd area of earth disturbance is re-rocked to ensure stabilization is maintained.Mr. Small also stated new well tags will be installed immediately.
2241814 Primary Facility 2014-02-03 Routine/Partial Inspection No Violations Noted Multi-well pad. Marcellus. Site ID sign present, in compliance with Act 9 standards. E&S/PCSM plan, PPC plan, ERP at access road entrance. Gated.
2314428 Primary Facility 2014-10-17 Site Restoration No Violations Noted Multi-well pad. Marcellus. Site ID sign present, in compliance with Act 9 standards. E&S/PCSM plan, PPC plan, ERP, ESCGP-1 at access road entrance. Well site surrounded by security gate.
2331468 Primary Facility 2014-12-22 Routine/Complete Inspection No Violations Noted Multi-well pad. Marcellus. Site ID sign present, in compliance with Act 9 standards. E&S/PCSM plan, PPC plan, ERP, ESCGP-1 at access road entrance. Well site surrounded by security gate.
2627996 Primary Facility 2017-08-22 Routine/Complete Inspection No Violations Noted Multi-well pad. At time of inspection, wells 10H, 8H, and 9H are drilled and appear equipped for production.
2826985 Primary Facility 2019-01-15 Routine/Complete Inspection No Violations Noted On 1/15/19 at 1127 hrs., I conducted a routine inspection of Chevron Appalachia, LLC's Buterbaugh 10H well (API 063-37021) in Green Twp., Indiana Co. Snow cover prevented proper evaluation of site stabilization. The well pad appears to be restored and permanently stabilized. Three production fluid tanks are located within adequate secondary containment. Three wells are drilled and equipped for production. A site ID sign and permit box are posted at the site entrance. It is unclear as to whether or not well tags are affixed to any of the well heads as the perimeter fence to the well pad is locked. The Department requests that the operator provide either a combination or key to one of the locks to facilitate access to the site. This should be sent to the Department inspector listed on this report. There are no violations noted for this inspection.

For data sources see[8]

References