X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20287

Well Details

Well ID: 37-081-20287
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Franklin Township
Operator Name: XTO ENERGY INC
Well Pad ID: 148304
Farm/Lease Name: EVERBE FARMS 8518H
License Status:
Spud Date:
Permit Date: 2010-04-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.233928
Longitude: -76.633736

For data sources see[1][2][3]

Well History

Date Event
2010-04-21 New Permit Application
2010-10-19 Performed Spud Operation
2010-11-27 Drilling Completion
2011-01-19 Perforation
2015-08-20 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-02-10 2011-02-10 4,907 5,479,698

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Scale Inhibitor - Greenhib 677 Chemplex Scale Inhibitor
Other (75) 75.00 0.02
Salt of phosphonomethylated diamine 25.00 0.00668000
Acid - 7.5 HCl Acid Skylkine Chemical Corp. Cleaning Water 7732-18-5 92.50 0.31
Whole Product
Hydrochloric acid 7647-01-0 7.50 0.02
Acid Iron Chelating Agt Ferriplex 40 Chemplex Acid Iron Chelating Nitrilotriacetic acid trisodium monohydrate 18662-53-8 40.00 0.00050000
Sodium sulfate 7757-82-6 2.00 0.00002000
Other -(non hazardous) 57.00 0.00071000
Sodium hydroxide 1310-73-2 1.00 0.00001000
Water Water 7732-18-5 100.00 89.19
Friction Reducer - Plexslick 921 Chemplex Friction Reducer
Other (70) 70.00 0.03
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
Biocide - Plexcide 24L Chemplex Biocide Sodium hydroxide 1310-73-2 4.00 0.00119000
Other (72) 72.00 0.02
Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione 533-74-4 24.00 0.00715000
Sand Proppant Quartz 14808-60-7 100.00 10.35
Acid Non Emulsifier PlexBreak-145 Chemplex Acid Non-Emulsifier Methanol 67-56-1 15.00 0.00005000
Other -(non hazardous) 85.00 0.00029000
Acid Corrosion Inhibitor Plexhib 256 Chemplex Acid Corrosion Inhibitor
Methanol 67-56-1 40.00 0.00013000
Other -(non hazardous) 52.00 0.00017000
Propargyl alcohol 107-19-7 8.00 0.00003000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2011 XTO ENERGY INC 776,567.00 301 0.00 0 0.00 0
2012 XTO ENERGY INC 522,009.00 357 0.00 0 0.00 0
2013 XTO ENERGY INC 364,191.00 365 0.00 0 0.00 0
2014 XTO ENERGY INC 299,331.00 365 0.00 0 0.00 0
2015 XTO ENERGY INC 215,109.00 345 0.00 0 0.00 0
2016 XTO ENERGY INC 210,751.00 347 0.00 0 0.00 0
2017 XTO ENERGY INC 177,166.00 354 0.00 0 0.00 0
2018 XTO ENERGY INC 196,480.24 365 0.00 0 0.00 0
2019 XTO ENERGY INC 168,966.99 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 XTO ENERGY INC Produced Fluid 910.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 XTO ENERGY INC Fracing Fluid Waste 1,017.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2011 XTO ENERGY INC Produced Fluid 3,467.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2011 XTO ENERGY INC Produced Fluid 3,468.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC001
2011 XTO ENERGY INC Produced Fluid 115.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011 XTO ENERGY INC Produced Fluid 2,322.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 XTO ENERGY INC Produced Fluid 100.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-133-24189
2011 XTO ENERGY INC Fracing Fluid Waste 1,048.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 XTO ENERGY INC Produced Fluid 150.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2011 XTO ENERGY INC Produced Fluid 381.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2011 XTO ENERGY INC Produced Fluid 3,631.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2012 XTO ENERGY INC Produced Fluid 1,599.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2012 XTO ENERGY INC Produced Fluid 742.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2012 XTO ENERGY INC Produced Fluid 104.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 XTO ENERGY INC Produced Fluid 4,442.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 XTO ENERGY INC Produced Fluid 108.00 Bbl INJECTION DISPOSAL WELL 114
2012 XTO ENERGY INC Produced Fluid 525.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2012 XTO ENERGY INC Produced Fluid 1,190.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2012 XTO ENERGY INC Produced Fluid 108.00 Bbl INJECTION DISPOSAL WELL 0114
2013 XTO ENERGY INC Produced Fluid 262.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2013 XTO ENERGY INC Produced Fluid 738.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 XTO ENERGY INC Produced Fluid 396.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XTO ENERGY INC Produced Fluid 316.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 XTO ENERGY INC Produced Fluid 485.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XTO ENERGY INC Produced Fluid 221.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2014 XTO ENERGY INC Produced Fluid 104.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2014 XTO ENERGY INC Produced Fluid 1,859.93 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XTO ENERGY INC Produced Fluid 25.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2014 XTO ENERGY INC Produced Fluid 301.95 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XTO ENERGY INC Produced Fluid 724.58 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 XTO ENERGY INC Produced Fluid 774.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2015 XTO ENERGY INC Produced Fluid 109.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2015 XTO ENERGY INC Produced Fluid 1,139.31 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 XTO ENERGY INC Produced Fluid 1,123.47 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 XTO ENERGY INC Other Oil & Gas Wastes 3.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 XTO ENERGY INC Produced Fluid 1,201.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 XTO ENERGY INC Produced Fluid 458.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 XTO ENERGY INC Produced Fluid 616.58 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 XTO ENERGY INC Produced Fluid 103.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2016 XTO ENERGY INC Produced Fluid 256.19 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 XTO ENERGY INC Produced Fluid 764.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2017 XTO ENERGY INC Produced Fluid 114.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2017 XTO ENERGY INC Produced Fluid 2,573.70 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 XTO ENERGY INC Produced Fluid 104.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2017 XTO ENERGY INC Produced Fluid 431.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 XTO ENERGY INC Produced Fluid 215.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 XTO ENERGY INC Produced Fluid 652.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 XTO ENERGY INC Produced Fluid 656.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 XTO ENERGY INC Produced Fluid 520.03 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 XTO ENERGY INC Produced Fluid 108.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2019 XTO ENERGY INC Produced Fluid 683.50 Bbl INJECTION DISPOSAL WELL 34-133-21076
2019 XTO ENERGY INC Produced Fluid 568.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2019 XTO ENERGY INC Produced Fluid 456.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2019 XTO ENERGY INC Produced Fluid 299.00 Bbl REUSE (AT WELL PAD)
2019 XTO ENERGY INC Produced Fluid 111.00 Bbl INJECTION DISPOSAL WELL 34-133-20114

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1929241 Primary Facility 2010-11-22 Drilling/Alteration No Violations Noted
1942533 Primary Facility 2011-01-05 Routine/Partial Inspection Violation(s) Noted
1942534 Primary Facility 2011-01-06 Follow-up Inspection Violation(s) & Outstanding Violations
1946127 Primary Facility 2011-01-20 Routine/Partial Inspection Violation(s) Noted
1946141 Primary Facility 2011-01-25 Routine/Partial Inspection Outstanding Violations - No Viols Req'd
1947228 Primary Facility 2011-01-28 Routine/Complete Inspection No Violations Noted
1950446 Primary Facility 2011-02-16 Routine/Partial Inspection Violation(s) Noted
1960306 Primary Facility 2011-03-25 Follow-up Inspection No Violations Noted
1974204 Primary Facility 2011-05-17 Follow-up Inspection No Violations Noted
1974925 Primary Facility 2011-05-20 Routine/Complete Inspection No Violations Noted
1987477 Primary Facility 2011-07-11 Follow-up Inspection Violation(s) Noted
2012746 Primary Facility 2011-10-19 Routine/Complete Inspection Outstanding Violations - No Viols Req'd
2074214 Primary Facility 2012-06-06 Routine/Complete Inspection No Violations Noted
2106600 Primary Facility 2012-10-05 Routine/Complete Inspection No Violations Noted
2161173 Primary Facility 2013-04-24 Routine/Complete Inspection Outstanding Violations - No Viols Req'd
2287499 Primary Facility 2014-07-14 Routine/Complete Inspection No Violations Noted NOT inspection. site not restored, erosion channels noted on two separate locations going outside the LOD. Violations noted to the ESCGP
2410502 Primary Facility 2015-09-21 Routine/Complete Inspection No Violations Noted This inspection is in response to XTO's recent notification that violations cited on 7/14/2014 have been corrected. The PCSM plans incorporated into a major modification approved 4/13/2015 have been implemented. Vegetation has been established but has not yet reached 70% uniform perennial cover. Some slight erosion was noted exiting the same rock-lined ditch noted on 7/14/2015 but that area is now contained within the infiltration basin. Violations cited on 7/14/2015 are considered closed. In addition, The well site has not been restored. No Violations Noted.
2433655 Primary Facility 2015-12-14 Routine/Complete Inspection No Violations Noted Arrived at 14:15, weather hot and cloudy. There were two wells TD’d on this location.
2514927 Primary Facility 2016-08-24 Site Restoration No Violations Noted Notice of Termination/Well Site Restoration Report Inspection; 8/24/2016.

I entered the site at 15:05 to find two wells in production. The stormwater BMP’s identified in the PCSM (Post Construction Stormwater Management) plan have been implemented and the well site is permanently stabilized. The well site has not been re-graded and restored as the restoration plan indicates. This concept is further reiterated by your submission of the 2-year extension request (approved on 10/29/2015) which provides additional time to restore the site if stormwater is handled for the entire remaining site. I recommend approving the Notice of Termination at this time and denying the Well Site Restoration Report. I encourage you to submit the Well Site Restoration Report when the well site is restored so that permanent stabilization is established by the end of the extension period. No Violations Noted.

2528550 Primary Facility 2016-10-13 Site Restoration No Violations Noted Well Site Restoration Report Inspection; 10/13/2016.

I entered the site at 12:51 to find two wells (081-20287 and 081-20414) in production. The stormwater BMP’s identified in the PCSM (Post Construction Stormwater Management) plan have been implemented and the well site is permanently stabilized. A 2-year restoration extension was issued on 10/29/2015.

In the last inspection on 8/24/2016, the ESCGP was terminated. Since the last inspection, the ESCGP was modified so that the entire well pad surface can be retained while the well is in production. The operator provided justification that the pad surface is required to accommodate the production/maintenance of the wells and for work-over rig access. I recommend the Well Site Restoration Report be approved. No Violations Noted

2773934 Primary Facility 2018-09-12 Routine/Complete Inspection No Violations Noted Two wells staged for production phase. Two each sand and water separators. No leaks detected from production equipment. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1942533 602916 01/05/2011 2011-01-05 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. Environmental Health & Safety Drill mud / cuttings on pad
1942533 602917 01/05/2011 2011-01-05 CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit Environmental Health & Safety
1942533 602918 01/05/2011 2011-01-05 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative 78.56(a) Drill mud / cuttings on ground. Not contained
1942533 602919 01/05/2011 2011-01-05 91.33POLLINC - Pollution incident was not reported to DEP. Environmental Health & Safety
1942534 602920 01/06/2011 2011-01-06 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. Environmental Health & Safety Drill mud / cuttings on pad
1942534 602921 01/06/2011 2011-01-06 CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit Environmental Health & Safety
1942534 602922 01/06/2011 2011-01-06 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative 78.56(a) Drill mud / cuttings on ground. Not contained
1946127 603757 01/20/2011 2011-01-20 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative 78.56(a) Failure to contain pollutional substance
1946127 603758 01/20/2011 2011-01-20 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety
1946127 603759 01/20/2011 2011-01-20 CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit Environmental Health & Safety
1950446 604980 02/16/2011 2011-02-16 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. Environmental Health & Safety
1950446 604981 02/16/2011 2011-02-16 91.33POLLINC - Pollution incident was not reported to DEP. Environmental Health & Safety
1950446 604982 02/16/2011 2011-02-16 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety
1987477 615226 07/11/2011 2011-07-11 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative Defective Cement: Gas found in the annular space of the 9 5/8 x 5 1/2 casing.

For data sources see[8]

References