37-085-23691

Well Details

Well ID: 37-085-23691
Loading map...
Country: United States
State: Pennsylvania
County: Mercer
Municipality: Pymatuning Township
Operator Name: NUCOMER ENERGY LLC
Well Pad ID:
Farm/Lease Name: J WOODS 1
License Status: ACTIVE
Spud Date:
Permit Date: 2004-12-17
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.347334
Longitude: -80.456922

For data sources see[1][2][3]

Well History

Date Event
2004-12-17 New Permit Application
2004-12-31 Performed Spud Operation
2005-01-08 Drilling Completion
2005-09-22 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2004 COBRA RESOURCES LLC 0.00 0 0.00 0 0.00 0
2005 COBRA RESOURCES LLC 475.00 365 0.00 0 0.00 0
2006 COBRA RESOURCES LLC 481.00 365 0.00 0 0.00 0
2007 COBRA RESOURCES LLC 274.00 365 0.00 0 0.00 0
2008 COBRA RESOURCES LLC 0.00 0 0.00 0 0.00 0
2009 COBRA RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 STRYKER ENERGY LLC 1,180.00 336 0.00 0 0.00 0
2013 STRYKER ENERGY LLC 588.07 365 0.00 0 0.00 0
2014 STRYKER ENERGY LLC 327.00 365 0.00 0 0.00 0
2015 STRYKER ENERGY LLC 987.29 336 0.00 0 0.00 0
2016 STRYKER ENERGY LLC 1,765.00 274 0.00 0 0.00 0
2017 NUCOMER ENERGY LLC 0.00 0 0.00 0 0.00 0
2018 NUCOMER ENERGY LLC 336.00 149 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1406752 Primary Facility 2005-01-05 Drilling/Alteration No Violations Noted
1994617 Primary Facility 2011-07-28 Routine/Complete Inspection Violation(s) Noted
2002939 Primary Facility 2011-09-15 Compliance Evaluation No Violations Noted
2533354 Primary Facility 2016-11-01 Routine/Partial Inspection No Violations Noted
2761003 Primary Facility 2018-07-31 Routine/Partial Inspection No Violations Noted Tubing and production casing are open to the separator unit. Valves on separator are shut. Monthly production chart is dated 2/6/17 and has no production. Well has not been used for production since

Well will be reinspected after annual production report for 2018 has been submitted on February 15, 2019.

Correct all the issue noted in this inspection before March 2019 to avoid violations for 3220(A) and 3211(H).

2822213 Primary Facility 2019-01-04 Routine/Complete Inspection No Violations Noted Routine inspection of conventional gas well with rabbit/plunger. No tag at wellhead. Annulus unknown; buried. Chart is from August 2018. Well is "temporarily not producing" on production report. Separator and tank in dike near road.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1994617 617433 07/28/2011 2011-07-28 210UNPLUG - Failure to plug a well upon abandonment Administrative
1994617 617434 07/28/2011 2011-07-28 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
617433 273747 NOV - Notice of Violation Comply/Closed 2011-09-15
617434 273747 NOV - Notice of Violation Comply/Closed 2011-09-15

For data sources see[6]

References