{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.088119,"lon":-79.97413,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: West Pike Run Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 148526 | |
Farm/Lease Name: HILL UNIT 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-10-01 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.088119 | |
Longitude: -79.974130 |
Date | Event |
---|---|
2009-10-01 | New Permit Application |
2010-01-25 | Performed Spud Operation |
2010-05-12 | Drilling Completion |
2010-08-10 | DEVIATED |
2010-09-07 | Perforation |
2010-09-08 | Performed Stimulation |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2010-09-08 | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ANTERO RESOURCES CORP | 174,082.00 | 83 | 0.00 | 83 | 0.00 | 83 |
2011 | ANTERO RESOURCES CORP | 724,630.00 | 364 | 0.00 | 181 | 1,330.00 | 364 |
2012 | ANTERO RESOURCES CORP | 558,106.25 | 348 | 0.00 | 0 | 42.00 | 165 |
2013 | ANTERO RESOURCES CORP | 459,643.82 | 359 | 0.00 | 0 | 0.00 | 0 |
2014 | ANTERO RESOURCES CORP | 185,709.13 | 357 | 0.00 | 0 | 0.00 | 0 |
2015 | ANTERO RESOURCES CORP | 277,443.82 | 221 | 0.00 | 0 | 0.00 | 0 |
2016 | ANTERO RESOURCES CORP | 348,594.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 92,798.00 | 117 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 241,422.00 | 283 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 211,467.00 | 339 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | ANTERO RESOURCES CORP | Fracing Fluid Waste | 15,686.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2010 | ANTERO RESOURCES CORP | Drill Cuttings | 803.04 Tons | IDENTIFY METHOD IN COMMENTS | |
2010 | ANTERO RESOURCES CORP | Produced Fluid | 91.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PBR |
2010 | ANTERO RESOURCES CORP | Produced Fluid | 8.25 Bbl | LANDFILL | |
2010 | ANTERO RESOURCES CORP | Produced Fluid | 1,046.00 Bbl | IDENTIFY METHOD IN COMMENTS | |
2010 | ANTERO RESOURCES CORP | Drilling Fluid Waste | 553.49 Bbl | IDENTIFY METHOD IN COMMENTS | |
2011 | ANTERO RESOURCES CORP | Drill Cuttings | 79.64 Tons | LANDFILL | |
2014 | ANTERO RESOURCES CORP | Drill Cuttings | 231.50 Tons | LANDFILL | SWF 1032-WV0109 |
2017 | EQT PROD CO | Produced Fluid | 308.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 427.79 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 156.91 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 60.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 191.38 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 32.50 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1879273 | Primary Facility | 2010-04-01 | Drilling/Alteration | No Violations Noted | Bronco 10 - Ready to run 13 3/8, site inspection showed possible leeching of hydrocarbon type fluid from well site pad. Contacted water quality specialist to have samples taken. Spoke to company man on site, showed him my concerns and directed him to dig a sump pit to capture fluid and keep pumped off. Also advise the pit on site should be inspected for possible leaks. Further investigation and monitoring to be done. |
1879278 | Primary Facility | 2010-04-14 | Drilling/Alteration | No Violations Noted | Bronco 10 - Closed system has been installed and pit is in process of being solitified. Drilling ahead |
1880649 | Primary Facility | 2010-04-20 | Routine/Complete Inspection | No Violations Noted | discussed pit solidifiation, liquids pumped off lined pit |
1886153 | Primary Facility | 2010-05-13 | Drilling/Alteration | No Violations Noted | Bronco 10 - Drilling completed and production string run, drilling rig and equipment being removed so site can be evualted better for clean up. This is an ongoing investigation site with Water Quality taking the lead . |
1887710 | Primary Facility | 2010-04-01 | Routine/Complete Inspection | Violation(s) Noted | The Department conducted an inspection in relation to discharge that is occurring on the back left corner of the site. The water has a slight dark tint to it and noticeable petroleum product sheen on top. The Department spoke with Rick Jones, company man on site. His initial belief is that the operator encountered a spring when building the location. This is what caused the discharge but to his knowledge, it had no contaminates present. The Department noted that a barrel of methanol was located 5 feet down slope from the discharge. The Department asked the operator to get the barrel out of the drainage swell. All of which point to a leak in the drilling pit. |
1887833 | Primary Facility | 2010-04-08 | Complaint Inspection | Violation(s) Noted | Complaint # 270271 was responded to by WQS Miller . Complainant' s water supply is within 1000 ft of gas well. Recently Antero had some production fluids released to the ground (drill cutting liquids, motor oil, and diesel fuel). Samples taken on 4/8/2010 show elevated parameters from pre-drill samples taken on 11/11/09. The Department has determined that the water supply has been impacted and that the operator is now required to replace and restore |
1887902 | Primary Facility | 2010-04-08 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | The Department met with Jeff Woodcock from Civil Environmental Consultants and split sampled. Results are attached. Furthermore, the Department also sampled for 942 analysis on 4/7/10. Sample number 0499-017 was taken at the sediment trap. Preliminary test results from samples that were taken on 04/01/2010 show elevated conductivity, iron, manganese, and TDS. Rick Jones from Antero, stated that a diesel spill had happened underneath the rig floor. Sample number 0499-017 was taken at the sediment trap. |
1887934 | Primary Facility | 2010-04-29 | Follow-up Inspection | Violation(s) & Recurring Violations | |
1888806 | Primary Facility | 2010-05-07 | Routine/Complete Inspection | Violation(s) Noted | An NOV was issued for spilling motor oil. Citations included 78.54 and SWMA Section 301. Mike Ward from Antero called to report a release of motor oil from a generator he discovered during a routine operations inspection. Upon arrival WQS Miller observed motor oil seeping out of the slope on the West and North sides of the well pad and into the sediment trap below the site. A review of the tool pusher's logs found that generator #1 had used 89 gallons of oil from 4/21/10-5/3/2010. Antero was keeping the oil realease on site with absorbent pads and socks. Al Anderson from Ryan Environmental was present and Miller gave him permission to install a floating under drain system in front of the sediment trap which would separate the oil from the water. All of the pads and waste oil would be collecterd in drums and bthen be sent for disposal. The water that was sent into the sediment trap via the under drain would be pumped into thanker trucks and sent out for disposal. DEP requested that Antero retain all analysis and diposal slips for review. |
1888839 | Primary Facility | 2010-05-13 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | The Department met with Jerry Alberts from Antero, and his contractors to discuss progress being made on the Hill Unit 2H site remediation. The initial seep located at the back left corner of the site now is lined and being pumped down periodically. The spilled cuttings have been cleaned up and put into a roll off dumpster to be taken to a landfill and be disposed of properly. SE Environmental is doing daily inpsections of the site and documenting every problem area that arises. The Department requested a copy of the daily logs. Futhermore, the operator has requested another meeting to discuss long term site remediation requirements. Seeps are still discharging discolored water and a recent 80 to 100 gallon motor oil spill is now also working out of the pad toward the sediment trap. |
1888846 | Primary Facility | 2010-05-20 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | A follow-up inspection was conducted to check remediation status. The rig and all the equipment have been taken off the site. Trailer trucks were removing the last bit of pipe and flanges from the site. The pit/sump has been collected oil for a few days and the oil seeps from the slopes have stopped. Mike Ward from Antero expects to start removing contaminated soil from the site within the next couple of days. |
1888944 | Primary Facility | 2010-05-25 | Complaint Inspection | Outstanding Violations - No Viols Req'd | The Department sampled for VOA DW. Once the sample results from the Department and Antero are compiled and reviewed, Antero will have to provide an action plan for water restoration/replacement. OUTNO viols linked to inspection # 1887833 |
1891061 | Primary Facility | 2010-06-03 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | outstanding viols tied to inspection 1885855, on 5/7/10 |
1892512 | Primary Facility | 2010-06-07 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | OUTNO vio linked to efacts inspection1888806, enf # 258705 |
1892781 | Primary Facility | 2010-06-01 | Complaint Inspection | Outstanding Violations - No Viols Req'd | OUTNO viols for Hill #2 linked to inspections 1887833 and 188806 |
1893359 | Primary Facility | 2010-06-10 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | OUTNO viols linked to inspections 1887833 and 11888806 |
1893430 | Primary Facility | 2010-06-15 | Complaint Inspection | No Violations Noted | |
1893433 | Primary Facility | 2010-06-15 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | OUTNOVIOS linked to inspections 1888806 and 1887833 |
1902067 | Primary Facility | 2010-06-29 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | OUTNO violations for Hill Unit #2, efacts inspection 1888806, enforcement# 258705 |
1906405 | Primary Facility | 2010-07-21 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | Outsatnding viols linked to eFACTS 1888806 and Enf# 258705 |
1908879 | Primary Facility | 2010-07-29 | Complaint Inspection | No Violations Noted | outno viols for Hill #2 under eFACTS 1888806, enf # 258705 |
1911350 | Primary Facility | 2010-08-27 | Compliance Evaluation | No Violations Noted | |
1944875 | Primary Facility | 2010-11-17 | Routine/Complete Inspection | No Violations Noted | |
1993160 | Primary Facility | 2010-06-01 | Complaint Inspection | Outstanding Violations - No Viols Req'd | OUTNO viols linked to inspection #1887833 |
1993188 | Primary Facility | 2011-04-14 | Complaint Inspection | Outstanding Violations - No Viols Req'd | OUTNO viols linked to inspection # 1887833 |
1995368 | Primary Facility | 2011-04-14 | Routine/Complete Inspection | Violation(s) Noted | |
2034304 | Primary Facility | 2011-11-03 | Compliance Evaluation | No Violations Noted | viols corrected from 4/14/11 inspection. eFACTS 1995368, enf# 273726 |
2038698 | Primary Facility | 2011-12-14 | Complaint Inspection | No Violations Noted | |
2259269 | Primary Facility | 2014-02-14 | Incident- Response to Accident or Event | Violation(s) Noted | |
2451758 | Primary Facility | 2016-02-23 | Routine/Complete Inspection | No Violations Noted | |
2509314 | Primary Facility | 2016-06-20 | Complaint Inspection | No Violations Noted | On 6/20/16, I performed a complaint inspection at the Hill/Hopkins site and JM Sphar 4 well in response to complaint 320508 and made the following observations:
•Water samples were collected for SAC 946 analysis in response to the complaint. •Hill/Hopkins Site: -Site was in generally good condition with two wells drilled. -Containment appeared to be well maintained. -Vegetation on site was patchy in some areas (behind production units and on cut slope above impoundment). -The depression around well 2H was filled with water. -No evidence was found of spills or leaks on the site at the time of inspection. •J M Sphar 4: The well and surrounding area were in good condition with no evidence of spills or leakage. Vegetation and berm around the well head and associated tank were also intact. |
2509324 | Primary Facility | 2016-06-20 | Complaint Inspection | No Violations Noted | On 6/20/16, I performed a complaint inspection at the Hill/Hopkins site and JM Sphar 4 well in response to complaint 320508 and made the following observations:
•Water samples were collected for SAC 946 analysis in response to the complaint. •Hill/Hopkins Site: -Site was in generally good condition with two wells drilled. -Containment appeared to be well maintained. -Vegetation on site was patchy in some areas (behind production units and on cut slope above impoundment). -The depression around well 2H was filled with water. -No evidence was found of spills or leaks on the site at the time of inspection. •J M Sphar 4: The well and surrounding area were in good condition with no evidence of spills or leakage. Vegetation and berm around the well head and associated tank were also intact. |
2511077 | Primary Facility | 2016-07-13 | Administrative/File Review | No Violations Noted | Administrative review of lab results on 7/13/16 indicates that the water supply does not appear to have been impacted by oil & gas activity. Results and documentation for complaint 320508 forwarded for final determination. |
2814466 | Primary Facility | 2018-11-07 | Administrative/File Review | No Violations Noted | On 11/7/18 an administrative inspection related to the Hill Unit Well Site was conducted to analyze the results of samples collected on 9/18/18. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1887710 | 588167 | 04/01/2010 | 2010-04-01 | 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table | Administrative | |
1887710 | 588169 | 04/01/2010 | 2010-04-01 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety | |
1887710 | 588170 | 04/01/2010 | 2010-04-01 | 91.33A - Failure to notify DEP of pollution incident. No phone call made forthwith | Administrative | |
1887833 | 588210 | 04/08/2010 | 2010-04-08 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | |
1887934 | 588235 | 04/29/2010 | 2010-04-29 | 78.60B - Tophole water discharged improperly | Administrative | |
1887934 | 588236 | 04/29/2010 | 2010-04-29 | 301CSL - Stream discharge of IW, includes drill cuttings, oil, brine and/or silt | Environmental Health & Safety | |
1888806 | 588635 | 05/07/2010 | 2010-05-07 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | |
1995368 | 617698 | 04/14/2011 | 2011-04-14 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
2259269 | 692367 | 02/14/2014 | 2014-02-14 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | ~400 gallons of production water was released onto the ground due to a tank failure. Proper notifications were made and clean up of material began immediately. A site remediation plan has been submitted for review. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
588167 | 258385 | NOV - Notice of Violation | Comply/Closed | 2010-08-27 | |||
588169 | 258385 | NOV - Notice of Violation | Comply/Closed | 2010-08-27 | |||
588170 | 258385 | NOV - Notice of Violation | Comply/Closed | 2010-08-27 | |||
588210 | 258410 | NOV - Notice of Violation | Comply/Closed | 2010-08-27 | |||
588210 | 298502 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2013-06-07 | 2013-06-07 | $148,250.00 | $148,250.00 |
588235 | 258421 | NOV - Notice of Violation | Comply/Closed | 2010-08-27 | |||
588235 | 298502 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2013-06-07 | 2013-06-07 | $148,250.00 | $148,250.00 |
588236 | 258421 | NOV - Notice of Violation | Comply/Closed | 2010-08-27 | |||
588236 | 298502 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2013-06-07 | 2013-06-07 | $148,250.00 | $148,250.00 |
588635 | 258705 | NOV - Notice of Violation | Comply/Closed | 2010-08-27 | |||
588635 | 298502 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2013-06-07 | 2013-06-07 | $148,250.00 | $148,250.00 |
617698 | 273726 | NOV - Notice of Violation | Comply/Closed | 2011-11-03 | |||
617698 | 284284 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2012-05-11 | 2012-05-11 | $5,250.00 | $5,250.00 |
692367 | 309406 | NOV - Notice of Violation | |||||
692367 | 369222 | COA - Consent Order and Agreement | 2018-11-06 | $75,000.00 | $75,000.00 |
For data sources see[8]