37-125-24461

Well Details

Well ID: 37-125-24461
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Deemston Borough
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148738
Farm/Lease Name: LATKANICH UNIT 1H
License Status:
Spud Date:
Permit Date: 2011-06-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.028517
Longitude: -80.047392

For data sources see[1][2][3]

Well History

Date Event
2011-06-29 New Permit Application
2011-09-14 Performed Spud Operation
2012-01-18 Drilling Completion
2012-11-07 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-07-11 2012-07-11 5,882 3,043,321

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Clean Volume (gals) Carrier/Base Fluid 90.95 100.00
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00292000
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.28
GBW-30 BREAKER Halliburton Energy Services Gel Breaker Carbohydrates 95.00 0.00009000
Hemicellulase enzyme 9012-54-8 15.00 0.00001000
Biocide EC 6116A Nalco Biocide Polyethylene glycol 25322-68-3 60.00 0.01
Dibromoacetonitrile 3252-43-5 5.00 0.00124000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00744000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00690000
Proppant (lbs) Proppant 9.05 10.03
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00736000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 126,964.00 92 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 503,690.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 377,560.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 279,740.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 203,346.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 185,130.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 160,082.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 143,736.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Produced Fluid 1,230.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 6.09 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 5,580.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 15,075.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 13,705.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 161.28 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Produced Fluid 4,844.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 15,440.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 200.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,541.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 66.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Produced Fluid 954.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 133.01 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 707.51 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 170.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 50.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017 CHEVRON APPALACHIA LLC Produced Fluid 2,755.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 160.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 56.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Other Oil & Gas Wastes 12.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 327.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 29.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 505.33 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2004385 Primary Facility 2011-09-21 Drilling/Alteration No Violations Noted Well spud, site and location under construction, E&S in place
2038733 Primary Facility 2012-01-05 Complaint Inspection No Violations Noted
2128295 Primary Facility 2012-12-14 Complaint Inspection Violation(s) Noted Pumping pit water to a non-vegetated area is a violation
2153304 Primary Facility 2013-01-09 Follow-up Inspection Outstanding Violations - No Viols Req'd On January 9, 2013 I stopped at he Latkanich site to check Chevron's progress at addressing the issues foud during my December 214, 2012 inspection. The pits were mostly filled in. I'll recheck the site later.
2153306 Primary Facility 2013-03-09 Compliance Evaluation No Violations Noted On March 9, 2013 I stopped at he Latkanich site to check Chevron's progress at addressing the issues foud during my December 214, 2012 inspection. The pit was filled in and I found no other violations.
2582953 Primary Facility 2017-02-22 Complaint Inspection No Violations Noted On 2/22/17, a complaint inspection was performed related to the Latkanich site in response to complaint 325171 and made the following observations:

•The complainant requested testing for radiological compounds as reportedly recommended to them by the Isaac Walton League. •The complainant reported suspected past improper disposal of fluids in former ponds on site. Previous inspections of site found no surface indications of spills or contamination. •Samples for 946 and bacteriological analysis were obtained from the tap before the complainants holding tank before any filtration after a 10 minute flush of the system. The sample appeared clear and no smell was noted (possibly due to strong odors present in basement). •The well bore is located roughly 20 feet from the house and has a secure cap elevated 6” off of the ground at the time of inspection. The complainant reported that the well was drilled to 275 feet deep in 1999 and has a poly case to 70 feet.

2585316 Primary Facility 2017-04-20 Administrative/File Review No Violations Noted On 4/20/17, an ADMIN inspection was conducted assisted by WQS Supervisor John Carson regarding the Latkanich site in response to complaint 325171 and made the following observations:

•Results from operator predrill samples taken 8/2/11 and post drill samples from 3/26/13 and 4/8/13 were analyzed in comparison to DEP samples obtained during inspection 2582952 on 2/22/17. Increases in levels of multiple parameters were noted but no conclusive indicators of oil and gas impact were observed.

2660489 Primary Facility 2017-11-08 Follow-up Inspection No Violations Noted On 11/8/17 an FUI inspection was conducted of the Latkanich well site in response to a complaint (CTS ID: 325171) accompanied by WQSS John Carson and DEP Dave McDermott. The following was observed:

>>Labeling on the production tanks was noted to be weathered and difficult to read.

>>Containment around a container labeled residual waste was found to be partially compromised and unlikely to hold sufficient liquids in the case of a spill or leak. Further information concerning the contents and providence of the tank have been requested from the operator.

>>Production equipment on site was noted to have developed substantial rust. Protection from further weathering and potential failure is encouraged.

>>The complainant reported ongoing concerns of impact to well water quality and damage to the home. Sample 3401-068 was collected for 946 and bacteriological analysis.

2774930 Primary Facility 2018-09-05 Administrative/File Review No Violations Noted On 9/5/18 an administrative inspection of the Latkanich Unit Well site conducted with Group Manager Dave McDermott and WQSS John Carson in response to ongoing investigations into site conditions. The following was found:

>>Multiple areas of the site including sections of the entrance, access road and pad were found to have been constructed contrary to permitted plans. This constitutes a violation of 25 Pa. Code § 78.53, 25 Pa. Code § 102.5(c), and 25 Pa. Code § 102.5(m)(4) in that the operator failed to construct to comply with permit conditions in constructing the site and failed to acquire required permits or permit modifications to alter the site from permitted plans.

2780145 Primary Facility 2018-09-26 Administrative/File Review No Violations Noted On 9/26/18 an administrative of the Latkanich Well Site was conducted to correct filing errors related to the below inspection:

Inspection ID: 2771088 On 9/5/18 an administrative inspection of the Latkanich Unit Well site conducted with Group Manager Dave McDermott and WQSS John Carson in response to ongoing investigations into site conditions. The following was found:

>>Multiple areas of the site including sections of the entrance, access road and pad were found to have been constructed contrary to permitted plans. This constitutes a violation of 25 Pa. Code § 78.53, 25 Pa. Code § 102.5(c), and 25 Pa. Code § 102.5(m)(4) in that the operator failed to construct to comply with permit conditions in constructing the site and failed to acquire required permits or permit modifications to alter the site from permitted plans.

2807705 Primary Facility 2018-10-30 Complaint Inspection No Violations Noted On 10/30/18 a complaint inspection related to the Latkanich Unit was conducted in response to a water supply complaint (CTS ID: 332897). Water samples were collected for 946 and radiological compound testing (the latter were sent to a third party lab for analysis).
2853256 Primary Facility 2019-03-13 Complaint Inspection No Violations Noted On 3/13/19 a complaint inspection related to the Latkanich Well Site was conducted in response to complaint 332897, the following was observed:

>>Water samples were collected for standard chemical and biological analysis.

>>Survey of complainant's property found no evidence of surface impact or spill near well cap.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2128295 657164 12/14/2012 2012-12-14 401CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
2128295 657165 12/14/2012 2012-12-14 78.60B - Tophole water discharged improperly Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
657164 292311 NOV - Notice of Violation Comply/Closed 2013-04-04
657165 292311 NOV - Notice of Violation Comply/Closed 2013-04-04