X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-27182

Well Details

Well ID: 37-125-27182
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 145213
Farm/Lease Name: R. SMITH 592300
License Status:
Spud Date:
Permit Date: 2013-11-26
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.164772
Longitude: -79.944589

For data sources see[1][2][3]

Well History

Date Event
2013-11-26 New Permit Application
2013-12-06 Performed Spud Operation
2014-04-01 New Permit Application
2014-05-10 Drilling Completion
2014-06-13 Perforation
2014-06-13 Performed Stimulation
2016-06-23 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-06-13 2014-06-30 7,660 12,799,500 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 MC MX 8-2544 Multi-Chem Live Culture-Nitrate Reducing Bacteria Proprietary NA 60 0.00882179 10844.2
Hydrochloric Acid (15%) U.S. Well Services Acidizing Hydrochloric Acid 7647-01-0 15 0.0414044 50896.2
Sand (Proppant) U.S. Well Services Proppant Silica Substrate 14808-60-7 100 12.4618 15,318,600.0
MC MX 5-2402 Multi-Chem Sodium nitrate brine Sodium nitrate 7631-99-4 60 0.0777605 95586.7
LGC-15 U.S. Well Services Gelling Agent Petroleum distillates 64742-47-8 60 0.0203446 25008.6
AP One U.S. Well Services Gel breaker Ammonium persulfate 7727-54-0 100 0.00787681 9682.54
Water U.S. Well Services Carrier/Base Fluid Water 7732-18-5 100 86.8919 106,811,000.0
PH-15L U.S. Well Services Buffering agent Sodium chloride 7647-14-5 7 0.000165484 203.42
Sodium hydroxide 1310-73-2 60 0.00141843 1743.6
SI-1100 U.S. Well Services Scale inhibitor Ethylene glycol 107-21-1 40 0.0128865 15840.7
AI-301 U.S. Well Services Acid inhibitor Diethylene glycol 111-46-6 30 0.00002050 25.2
Polyethlenepolyamine 68603-67-8 10 0.00000683 8.4
Hydrogen chloride 7647-01-0 10 0.00000683 8.4
Methenamine 100-97-0 20 0.00001367 16.8
Coco amine 61791-14-8 5 0.00000342 4.2
WFRA 405 U.S. Well Services Friction reducer Sodium chloride 7647-14-5 20 0.0299111 36768.1
Petroleum distillates 64742-47-8 40 0.0598221 73536.1

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-06-13 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 EQT PROD CO 0.00 0 0.00 0 0.00 0
2014 EQT PROD CO 366,330.00 69 0.00 0 0.00 0
2015 EQT PROD CO 2,939,051.00 359 0.00 0 0.00 0
2016 EQT PROD CO 2,686,446.00 347 0.00 0 0.00 0
2017 EQT PROD CO 1,848,611.00 311 0.00 0 0.00 0
2018 EQT PROD CO 1,294,371.00 364 0.00 0 0.00 0
2019 EQT PROD CO 949,415.00 322 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 EQT PROD CO Fracturing Fluid Waste 204.00 Tons LANDFILL 100592
2014 EQT PROD CO Drilling Fluid Waste 200.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2014 EQT PROD CO Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2014 EQT PROD CO Drill Cuttings 663.66 Tons LANDFILL 100419
2014 EQT PROD CO Drill Cuttings 536.50 Tons LANDFILL 100277
2014 EQT PROD CO Drilling Fluid Waste 4,375.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Fracing Fluid Waste 4,826.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 9,639.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Fracturing Fluid Waste 223.22 Tons LANDFILL SWF 1032-WV0109
2014 EQT PROD CO Produced Fluid 310.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2014 EQT PROD CO Drilling Fluid Waste 200.00 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2015 EQT PROD CO Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2015 EQT PROD CO Produced Fluid 1,760.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Fracing Fluid Waste 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 13,170.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 101.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016 EQT PROD CO Produced Fluid 251.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 670.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Produced Fluid 8,574.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 1,699.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 205.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 480.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 12.43 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 EQT PROD CO Produced Fluid 69.72 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid 2,775.87 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 74.08 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 91.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 807.22 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 10.45 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Produced Fluid 55.94 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 564.51 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 24.27 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 18.47 Bbl INJECTION DISPOSAL WELL 34-167-29543
2019 EQT PROD CO Produced Fluid 1.90 Bbl INJECTION DISPOSAL WELL 34-167-28462
2019 EQT PROD CO Other Oil & Gas Wastes 212.50 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 52.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 5.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 624.67 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 19.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 13.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2231136 Primary Facility 2013-12-19 Drilling/Alteration No Violations Noted Alpha-Hunter drilling for EQT using CLS and flare stack . Currently drilling the 592303 well. Cellar and conductor set for this well. Containment under rig and support equipment. No violations at time of inspection.
2238581 Primary Facility 2014-01-14 Drilling/Alteration No Violations Noted
2267841 Primary Facility 2014-05-02 Drilling/Alteration No Violations Noted Pioneer Rig 72
2268587 Primary Facility 2014-05-05 Drilling/Alteration No Violations Noted Pioneer Rig 72
2272384 Primary Facility 2014-05-13 Drilling/Alteration No Violations Noted Pioneer Rig 72
2340217 Primary Facility 2015-01-30 Routine/Complete Inspection No Violations Noted Violations for todays inspection linked to site inspection 2340109 enforcement 319619
2343345 Primary Facility 2015-02-10 Routine/Complete Inspection No Violations Noted Well in production. Well in compliance with environmental regulations.
2350217 Primary Facility 2015-03-10 Routine/Complete Inspection No Violations Noted
2350346 Primary Facility 2015-02-24 Routine/Complete Inspection No Violations Noted
2361139 Primary Facility 2015-04-14 Routine/Complete Inspection No Violations Noted On April 14th 2015, I inspected the Robert Smith Pad in response to an NOT request and made the following observations:
2363368 Primary Facility 2015-02-10 Routine/Partial Inspection No Violations Noted On 2/10/15 took water samples from well (tap in garage) based on analysis code 946.
2363382 Primary Facility 2015-03-12 Administrative/File Review No Violations Noted On 3/12/15 administrative review of lab results with WQS Bryon Miller did not indicate that gas well activities have impacted the water supply at this time.
2402125 Primary Facility 2015-08-14 Compliance Evaluation No Violations Noted On 8/14/15, I inspected the Robert Smith site as a compliance evaluation inspection in response to the remediation report for a spill occurring on 1/31/15 and made the following observations:
2544054 Primary Facility 2016-09-14 Incident- Response to Accident or Event Violation(s) Noted On 9/14/16 I performed an incident response inspection at the Robert Smith Site in response to an operator reported spill (CTS ID: 322335) and made the following observations:

•On 9/6/16 EQT Corey Giles reported a spill of 100 gallons of produced fluids to the well pad. The spill was forwarded to the WQS on 9/14/16. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code § 78.54 for failing to control brine and other fluids resulting in discharge to the ground and failure to prevent pollution to the Waters of the Commonwealth. •The spill was cleaned up at the time of inspection with the only observed indicator of the spill location being an area of new gravel on the pad near the production units. No violation. •Well drilling was ongoing at the time of inspection. •During general pad inspection it was noted that multiple production tanks had orange streaking running down their sides from the top of the tanks. The gravel of the pad surface near the containment displayed matching orange stai

2614147 Primary Facility 2017-05-05 Incident- Response to Accident or Event In Compliance with Policy On 5/5/17 an INCDT inspection of the R. Smith well site was conducted in response to CTS ID: 326715. The following was observed:

>> Site was undergoing fracking at time of inspection.

>>The spill in question involved roughly 10 gallons of produced water being sprayed from from an overfilled accessory tank on the pad. Affected pad materials were collected and placed in a waste box on pad for disposal. No violation, site appears to be in compliance with policy.

>>Streaking was again noted on the outside of multiple production tanks similar to streaking noted in previous inspections.

2660121 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:

>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation.

>>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection.

>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation.

>>Drilling was ongoing at the site at the time of inspection.

2705427 Primary Facility 2018-03-13 Routine/Partial Inspection No Violations Noted On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad. The following was observed:

>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities. No drilling rig was present on site at the time of inspection.

>>Construction of a proposed AST had not begun at the time of inspection.

>>Many water trucks were present on site in association with the attached impoundment.

2737806 Primary Facility 2018-05-16 Incident- Response to Accident or Event No Violations Noted On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18. The following was observed:

>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first. Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection. This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected.

>>Site inspection found no residual evidence of the spill. The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters).

2747132 Primary Facility 2018-06-29 Routine/Partial Inspection No Violations Noted On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident. The following was observed:

>>An unstabilized soil pile near the corner of the pad with a newly improved drain. Controls below the pile were absent though the vegetation was sufficient. No violation, remediation recommended.

>>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road. No controls beyond vegetation were present below the soil pile. No violation, monitoring recommended.

>>An AST was present on the accessory pad.

>>The pad was active at the time of inspection with drilling preparations ongoing. A sound wall was present around the pad perimeter.

2761844 Primary Facility 2018-08-02 Routine/Complete Inspection No Violations Noted On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad. WQSS John Carson accompanied. The following was observed:

>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization. The vegetative strip below remains in good condition. Remediation recommended, no violation.

>>Emptying partially filled containment is encouraged to aid in identifying any possible leaks. No violation.

>>No evidence of excessive or unpermitted runoff from the pad was found.

>>Box in containment appears to be collecting emergency blowdown. If so it should be properly marked. No violation.

2826221 Primary Facility 2019-01-11 Drilling/Alteration No Violations Noted Patterson-UTI Drilling Rig #277 moved onto this well on 12/26/18 and cleaned out well bore to 6076 ft. KB. TOOH and picked up 3 1/2" fiberglass tubing. Set kick plug from 6078 ft. to 4743 ft. on 12/28/18. Started sidetrack at 4743 ft. on 12/29/18. KOP was at 4930 ft. EOB was at 8015 ft. MD (7275 ft. TVD). TD was at 14,095 ft. MD (7272.48 ft. TVD) on 1/4/19. The 5 1/2" casing was set at 14,081.5 ft. Estimated TOC 3807 ft.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2544054 774403 2016-09-14 78.57(a) Environmental Health & Safety
2544054 774404 2016-09-14 78.54 Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
774403 349407 NOV - Notice of Violation
774404 349407 NOV - Notice of Violation

For data sources see[9]

References