X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-129-00544

Well Details

Well ID: 37-129-00544
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Hempfield Township
Operator Name:
Well Pad ID:
Farm/Lease Name: E KEMERER 1
License Status: ACTIVE
Spud Date:
Permit Date:
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.308314
Longitude: -79.644492

For data sources see[1][2][3]

Well History

Date Event
1916-11-03 Drilling Completion
1953-04-01 OLD WELL

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2003 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2006 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2007 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2008 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2009 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2010 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2011 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2012 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2013 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1813488 Primary Facility 2009-07-15 Routine/Complete Inspection No Violations Noted storage / 0 psi - murrysville
2016552 Primary Facility 2011-11-02 Routine/Complete Inspection No Violations Noted FUTURE ; SPEECH/TIONA; 1 PSIG; OPEN ANNULUS; NOT TIED IN
2173347 Primary Facility 2013-06-07 Routine/Complete Inspection No Violations Noted Preparing to plug and abandon old production well outsiide Oakford storage; Rigged up to pull 3 1/2 csg on packer out of hole; 2398 of 3 1/2" pulled after breaking off above packer. attempting to fish out remaining pipe and packer; As of 6/7/13; 8 5/8' csg broke off at surface; fluid flowing back was contained with no seepage; nippling up on 8/5/8 to keep rigid while pulling tubing;
2177994 Primary Facility 2013-06-13 Routine/Complete Inspection No Violations Noted fishing out 20' of 3.5" csg on packer. running 6 1/8" mill shoe to run down over casing to retrieve;
2178111 Primary Facility 2013-06-25 Routine/Complete Inspection No Violations Noted Packer removed with 3 !/2" casing above it; Attempting to fish out remaining casing in hole;
2190356 Primary Facility 2013-08-07 Plugging(Includes Plugged/Mined Through) No Violations Noted Dominion well outside Oakford storage (a future well) being plugged and abandoned; 1st plug from 2670 to 1990 cemented w/ 15.6ppg Class A cement with Gastop; 55 bbls; 262 sks; top of plug @2089'; next set of plugs @ 2072 cement to 1505'; 125 sks Class A; 2nd plug from 1505 to 940' set @ bottom of 8 5/8" @ 935; 32 bbls of cement (150 sks); 15.8 ppg; with 10% salt. Cement setting up; will attempt to pull 8 5/8" casing;
2214881 Primary Facility 2013-10-17 Site Restoration No Violations Noted Certificate of Plugging received by the Department on 10/3/2013. At the time of inspection the well appeared to be plugged. The site has been regraded seeded and mulched. Permanent monument installed. The site also appears to meet the restoration criteria of 70% uniform vegetative coverage.

For data sources see[6]

References