37-129-26229

Well Details

Well ID: 37-129-26229
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Fairfield Township
Operator Name: DIVERSIFIED OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: ROBERT MURPHY 6-WES
License Status:
Spud Date:
Permit Date: 2006-03-10
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.343161
Longitude: -79.116226

For data sources see[1][2][3]

Well History

Date Event
2006-03-10 New Permit Application
2006-07-11 Performed Spud Operation
2006-07-16 Drilling Completion
2011-01-11 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2006 TEXAS KEYSTONE INC 20,045.00 81 0.00 0 0.00 0
2007 TEXAS KEYSTONE INC 38,681.00 359 0.00 0 0.00 0
2008 TEXAS KEYSTONE INC 12,111.00 357 0.00 0 0.00 0
2009 TEXAS KEYSTONE INC 7534.00 345 0.00 0 0.00 0
2010 TEXAS KEYSTONE INC 3,233.00 314 0.00 0 0.00 0
2011 TEXAS KEYSTONE INC 1,967.00 297 0.00 0 0.00 0
2012 TEXAS KEYSTONE INC 1,275.00 324 0.00 0 0.00 0
2013 TEXAS KEYSTONE INC 521.00 314 0.00 0 0.00 0
2014 TEXAS KEYSTONE INC 374.00 289 0.00 0 0.00 0
2015 TEXAS KEYSTONE INC 8.00 7 0.00 0 0.00 0
2016 DIVERSIFIED OIL & GAS LLC 148.00 50 0.00 0 0.00 0
2017 DIVERSIFIED OIL & GAS LLC 60.00 14 0.00 0 0.00 0
2018 DIVERSIFIED OIL & GAS LLC 331.00 365 0.00 0 0.00 0
2019 DIVERSIFIED OIL & GAS LLC 343.00 303 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1599162 Primary Facility 2007-01-12 Routine/Complete Inspection No Violations Noted WELL DRILLED, PLUMBED, TAGGED, IN PRODUCTION. E&S OK.
1826172 Primary Facility 2009-09-03 Site Restoration No Violations Noted Well site has been restored. There are no signs of erosion and sedimentation on the access road and well site. Brine tank is in sound condition. Well site has adequate vegetative cover. Operator should continue to monitor the well site and access road for erosion and sedimentation.
2385541 Primary Facility 2015-06-29 Routine/Complete Inspection Violation(s) Noted Access road gated and shared with an agricultural field. At the time of inspection well appears equipped for production. Well tag present and permanently affixed to wellhead. Site permanently stabilized. No E&S issues in relation to site and/or access road.
2385580 Primary Facility 2015-07-02 Follow-up Inspection Outstanding Violations - No Viols Req'd Inspection performed as part of a follow-up to 6/29/2015 inspection (Insp.# 2385541 Enf.# 325237).
2393211 Primary Facility 2015-07-23 Administrative/File Review Outstanding Violations - No Viols Req'd On 7/23/2015 @14:00 Department spoke with Mr. Adamo (Operator) to confirm receipt and discuss soil sample test results and clean-up relating to Insp.#2385541 and Enf.#325237. Operator informed that less than 3 gallons of petroleum/oil based material was released. All visibly impacted material was excavated and properly stored pending the return of sampling results. Soil sampling results indicate adequate excavation of impacted area. Department recommends the Operator properly dispose of all impacted material and restore site in accordance with Spill Policy.
2395284 Primary Facility 2015-07-27 Compliance Evaluation No Violations Noted This inspection was performed as a Compliance Evaluation to Inspection ID 2385580 upon receipt of soil sampling test results. It appears Operator removed all visibly impacted soil and additionally sampling tests results indicate adequate excavation of impacted area. At the time of inspection, excavated area has been backfilled, seeded and mulched. All temporary E&S controls have been removed. Site permanently stabilized with no E&S issues. Department recommends Operator continue to perform routine maintenance of site in order to prevent a potential pollution event and/or accelerated E&S issues from occurring and to ensure the stability of site is maintained.
2579546 Primary Facility 2017-03-29 Routine/Complete Inspection No Violations Noted no issues system running.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2385541 727248 06/29/2015 2015-06-29 78.54 - GENERAL REQUIREMENTS - Operator failed to control and dispose of fluids, residual waste and drill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, and production fluids Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
727248 325237 NOV - Notice of Violation Comply/Closed 2015-11-02

For data sources see[6]