37-129-28462

Well Details

Well ID: 37-129-28462
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: South Huntingdon Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148513
Farm/Lease Name: HEPLER UNIT 2H
License Status:
Spud Date:
Permit Date: 2010-11-02
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.176694
Longitude: -79.702028

For data sources see[1][2][3]

Well History

Date Event
2010-11-02 New Permit Application
2010-12-03 Performed Spud Operation
2011-05-01 Drilling Completion
2011-06-29 Perforation
2013-10-23 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-07-06 2011-07-06 6,375 4,586,020

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.37
CMHPG Ashland Water Viscosifier Carboxymethylhydroxyporoyl guar blend 100.00 0.00335000
Scale Inhibitor A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00687000
Iron Control A Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00677000
GBL Clearwater International Gel Breaker Ethylene glycol 107-21-1 60.00 0.00005000
Clean Volume (gals) Carrier/Base Fluid 100.00 47.45
Unislik ST 50 CESI Chemical Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Proppant (lbs) Proppant 100.00 5.25
Biocide EC 6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5.00 0.00113000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00678000
Polyethylene glycol 25322-68-3 60.00 0.01

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 CHEVRON APPALACHIA LLC 124,721.00 31 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 1,215,736.00 366 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 679,525.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 454,045.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 289,041.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 289,202.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 250,747.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 218,016.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 182,757.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHEVRON APPALACHIA LLC Produced Fluid 310.00 Bbl INJECTION DISPOSAL WELL 34-121-2-3995
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 880.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 CHEVRON APPALACHIA LLC Produced Fluid 70.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHEVRON APPALACHIA LLC Fracing Fluid Waste 31,889.30 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHEVRON APPALACHIA LLC Fracing Fluid Waste 930.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 4,728.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 255.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2011 CHEVRON APPALACHIA LLC Produced Fluid 319.00 Bbl IDENTIFY METHOD IN COMMENTS 34-167-29359
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 2,565.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011 CHEVRON APPALACHIA LLC Produced Fluid 180.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 680.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Produced Fluid 3,324.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Produced Fluid 50.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 440.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 0.30 Tons LANDFILL 100419
2013 CHEVRON APPALACHIA LLC Produced Fluid 3,057.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Produced Fluid 45.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 314.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,000.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 618.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 347.34 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 332.02 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 1,616.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 221.67 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 111.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Soil Contaminated by Oil 0.08 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 CHEVRON APPALACHIA LLC Produced Fluid 74.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Soil Contaminated by Oil & Gas Related Spills 0.08 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2018 CHEVRON APPALACHIA LLC Produced Fluid 331.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 216.66 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 396.67 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1938893 Primary Facility 2010-11-30 Drilling/Alteration No Violations Noted YOST RIG DRILLING ON THE HEPLER PAD DEPTH 245'. E&S GOOD, HOUSE KEEPING GOOD, AND PITS GOOD.
1939450 Primary Facility 2010-12-07 Drilling/Alteration No Violations Noted YOST RIG DRILLING ON HEPLER PAD FOR ATLAS, FINISHED TOP HOLE AND SLIDE OVER TO THE 3H WELL.
1954911 Primary Facility 2011-02-18 Routine/Complete Inspection No Violations Noted Routine inspection of site.
1960350 Primary Facility 2011-03-22 Drilling/Alteration No Violations Noted HORIZONAL MARCELLUS
2038270 Primary Facility 2012-01-31 Routine/Complete Inspection No Violations Noted
2072634 Primary Facility 2012-06-04 Site Restoration No Violations Noted Site restoration inspection. No issues noted.
2153996 Primary Facility 2013-04-05 Complaint Inspection No Violations Noted Met with Matt Reager with Chevron on site. A citizen observed E&S issues on a Chevron lease. E&S issue was observed that needs to be addressed.
2157225 Primary Facility 2013-04-16 Follow-up Inspection No Violations Noted On 4/16/13 Sam Steingrabe conducted a follow up inspection at this site. Please read the above.Chevron repaired the erosional channel as requested. The repair looked great.
2365111 Primary Facility 2015-04-28 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus, brine tanks and gas production units appeared to be in sound condition. The site appaeres to be restored with good vegetative growth. No observation of accelerted erosion or sedmintaiton in realtion to the access road or well site.
2474611 Primary Facility 2016-04-13 Routine/Partial Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus, brine tanks and gas production units appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the access road or well site. See inspection #2474609 for additional observations regarding the site.
2558596 Primary Facility 2017-02-02 Routine/Partial Inspection No Violations Noted At the time of inspection, the well was drilled and equipped for production. The well apparatus, brine tanks and gas production units appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the access road or well site.

For data sources see[8]

References