37-129-28646

Well Details

Well ID: 37-129-28646
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Bell Township
Operator Name: CNX GAS CO LLC
Well Pad ID:
Farm/Lease Name: KUHNS 3C
License Status:
Spud Date:
Permit Date: 2011-08-02
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.508086
Longitude: -79.545861

For data sources see[1][2][3]

Well History

Date Event
2011-08-02 New Permit Application

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2059494 Primary Facility 2012-04-16 Routine/Complete Inspection No Violations Noted Inspection in response to a SPUD notice received of Thursday April 12 2012. At the time of inspection the site was being constructed. The E&S plan was on site and was properly implemented. The site was temporary stabilized as outlined in the E&S Plan. The Department notes an unlined pit onsite at the time of inspection. No accelerated erosion observed in relation to the access road or well pad area at the time of the inspection.
2086917 Primary Facility 2012-07-23 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled to the kickoff depth. The site appeared to be in sound condition. No accelerated or sedimentation observed in relation to the well pad or access road. The site has been temporarily stabilized and all BMP's appear to be properly installed and maintained. THE Department suggest the Operator continue to monitor the site on a weekly basis and after precipitation event to ensure E&S in not leaving the site.
2092852 Primary Facility 2012-08-20 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled but not equipped for production. The well pad appeared to be in sound condition. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained.
2127549 Primary Facility 2013-01-03 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled but not equipped for production. The well pad appeared to be in sound condition. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained.
2138175 Primary Facility 2013-02-11 Routine/Complete Inspection No Violations Noted
2147673 Primary Facility 2013-03-12 Routine/Complete Inspection No Violations Noted no violations noted
2151212 Primary Facility 2013-03-26 Routine/Complete Inspection No Violations Noted At the time of inspection the Operator indicated the well was drilled to total depth. The well pad appeared to be in sound condition with secondary containment underneath the drill rig. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained.
2160370 Primary Facility 2013-04-22 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled however not stimulated or equipped for production. During the inspection the Department notes that the Operator has started to prepare the site for stimulation. The Operator was in the process of excavating an area adjacent to the pad to store the Rock Water above ground storage container. The erosions and sedimentation plan was onsite and all associated BMPs appear to installed and functioning as outline in the plan. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained.
2166670 Primary Facility 2013-05-15 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled and the Operator was in the final stages of the stimulation set up process. Stimulation notice received by the Department on 5/11/2013 set for 5/16/2013. The Department notes that a 1 million gallon above ground freshwater containment vessel was installed and being filled at the time of inspection. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained.
2171427 Primary Facility 2013-06-03 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled and the Operator was in the process of stimulation. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The E&S plan was onsite and all associated BMPs appear to be installed and properly maintained. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained.Refer to inspection # 2171660 for violations issued on 6/3/2013 for release during completions operations.