X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-129-28728

Well Details

Well ID: 37-129-28728
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Sewickley Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149631
Farm/Lease Name: ZOROSAK UNIT 3H
License Status:
Spud Date:
Permit Date: 2012-01-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.223322
Longitude: -79.695950

For data sources see[1][2][3]

Well History

Date Event
2012-01-11 New Permit Application
2012-07-20 Performed Spud Operation
2012-10-18 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-05-13 2013-05-25 8,040 5,351,050

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Proppant Chevron Applachia, LLC Proppant Crystalline Sillica 14808-60-7 100 8.49 0
ASP 900 Nalco Friction Reducer Ammonium Sulfate 7783-20-2 30
CMHPG Ashland Water Viscosifier Carboxymethyl Hydroxporoyl Guar Blend 68130-15-4 100 0.00466 0
Unislik ST 50 CESI Friction Reducer Hydrotreated Light Distillite 64742-47-8 30 0.03303 0
EC 6116a Nalco Biocide Polyethylene Glycol 25322-68-3 60 0.01552 0
Dibromoacetonitrile 3252-43-5 5 0.00129 0
1, 1-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00776 0
Iron Control A Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00719 0
15% Hcl Acid Reagent/PPG Used to open perfs Hydrochloric Acid 7647-01-0 15 0.09336 0
GBL Clearwater Gel Breaker Ethylene Glycol 107-21-1 60 0.00007000 0
Scale Inhibitor A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00766 0
Clean Volume Chevron Applachia, LLC Carrier/Base Fluid H20 7732-18-5 100 91.51 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 367,955.00 121 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 958,091.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 613,007.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 419,864.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 319,182.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 289,561.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 237,451.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drill Cuttings 382.54 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 3,310.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 1,245.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 6,254.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 15,784.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Drill Cuttings 431.52 Tons LANDFILL 100419
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 410.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 5,762.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 158.37 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 45,229.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 2,394.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 1.43 Tons LANDFILL 073 114 654
2015 CHEVRON APPALACHIA LLC Produced Fluid 65.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015 CHEVRON APPALACHIA LLC Produced Fluid 935.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 255.01 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 445.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 45.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 219.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste 64.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 115.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 112.50 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 107.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 305.00 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 120.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2085312 Primary Facility 2012-07-23 Routine/Complete Inspection No Violations Noted Sediment laden water was coming out of #1 Sedimentation pond. Company immediately took steps to correct the problem.
2089540 Primary Facility 2012-07-24 Drilling/Alteration No Violations Noted 7/24/2012 Cellar and conductor in place. Waiting on rig to drill top hole portion of well.
2093538 Primary Facility 2012-08-13 Drilling/Alteration No Violations Noted 8/13/2012 Cellar and conductor in place. Waiting on rig to drill top hole portion of well. Site is still being constructed.
2100994 Primary Facility 2012-08-27 Drilling/Alteration No Violations Noted 8/27/2012 Keane 2144 drilling on Zorosak 3H, depth of 1613'.
2101086 Primary Facility 2012-09-07 Drilling/Alteration No Violations Noted 9/7/2012 Keane 2144 drilling depth of 6800'.
2110445 Primary Facility 2012-10-24 Drilling/Alteration No Violations Noted 10/24/12 Top hole rig gone, waiting on rig to drill lateral.
2120901 Primary Facility 2012-11-19 Drilling/Alteration No Violations Noted 11/19/12 Top hole rig gone, waiting on rig to drill lateral.
2123124 Primary Facility 2012-12-12 Drilling/Alteration No Violations Noted 12/12/2012Top hole rig gone, waiting on rig to drill lateral.
2127501 Primary Facility 2012-01-03 Drilling/Alteration No Violations Noted 01/03/2013Top hole rig gone, waiting on rig to drill lateral.
2128580 Primary Facility 2013-01-09 Drilling/Alteration No Violations Noted 01/09/2013Nabors rig 789 rigging up to drill lateral.
2136861 Primary Facility 2013-02-05 Drilling/Alteration No Violations Noted 2/5/2012 Nabors rig 789 finished lateral @ 13,309.
2162883 Primary Facility 2013-04-30 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drill, however the Operator indicated the well was not stimulated or equipped for production. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. Various pits located on site appear to be in sound condition and have the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2189081 Primary Facility 2013-08-05 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drill and equipped for production. The well apparatus, brine tanks and gas production units appear to be in sound condition. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. Various pits located on site appear to be in sound condition and have the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2248589 Primary Facility 2014-02-12 Routine/Complete Inspection No Violations Noted 2/12/2014 produced fluid tanks diked and GPU's. Inspected w/OGI P. Wyrwas.
2248605 Primary Facility 2014-02-26 Routine/Complete Inspection No Violations Noted 2/26/2014 produced fluid tanks diked and GPU's.
2272149 Primary Facility 2014-05-20 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drill and equipped for production. The well apparatus, brine tanks and gas production units appear to be in sound condition. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. Various pits located on site appear to be in sound condition and have the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2363433 Primary Facility 2015-04-07 Routine/Complete Inspection No Violations Noted
2378636 Primary Facility 2015-06-11 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The site was recently hydro seeded and showed signs of growth. The perimeter controls appeared to be sound condition and functioning properly.
2501353 Primary Facility 2016-07-14 Site Restoration No Violations Noted nspection in response to a "Well Site Restoration Report" received by the Department on 2/22/2016, at the time of inspection all earth disturbance activities were complete, PCSM BMP’s installed and functioning.
2683850 Primary Facility 2018-01-18 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Brine tank within secondary containment and appears to be structurally sound. Ground snow covered, no E&S issues observed.

For data sources see[8]

References