37-129-28743

Well Details

Well ID: 37-129-28743
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Sewickley Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148223
Farm/Lease Name: DERMOTTA UNIT 2H-A
License Status:
Spud Date:
Permit Date: 2012-02-08
Well Type: GAS
Unconventional Well: Y
Configuration: Deviated Well
Conservation: No
Latitude: 40.275631
Longitude: -79.765122

For data sources see[1][2][3]

Well History

Date Event
2012-02-08 New Permit Application
2012-04-26 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-01-29 2013-01-29 9,057 3,192,602

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WG-36 Halliburton Water Viscosifier Guar Gum 9000-30-0 100.0 0.00197
7.5 Hcl Acid Reagent/PP G Used to open perfs Hydrochloric Acid 7647-01-0 7.5 0.23638
EC 6116A Nalco Biocide Polyethylene Glycol 25322-68-3 60.0 0.01364
1,1-Dibromo-3-nitrilopropionamide 10222-01-2 30.0 0.00682
Proppant (lbs) Proppant 8.88 9.82471
ASP 900 Nalco Friction Reducer Ammonium Sulfate 7783-20-2 30.0 None
FR-66 Halliburton Friction Reducer Hydrotreated Light Distillite 64742-47-8 30.0 0.0349
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30.0 0.00687
EC6673W Nalco Iron Control Ethylene Glycol 107-21-1 30.0 0.00652
GBW-30 Halliburton Gel Breaker Carbohydrates 95.0 0.00071
Hemicellulase enzyme 9012-54-8 15.0 0.00011
Clean Volume (gals) Carrier/Base Fluid 91.12 100.0
EC6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5.0 0.00114

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 526,825.00 222 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 514,924.00 365 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 331,553.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 256,371.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 217,317.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 192,549.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 163,370.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drill Cuttings 893.30 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 20.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 6,845.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 11.80 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Produced Fluid 7,132.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,242.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 34,531.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 13.41 Tons LANDFILL 100592
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 66.59 Tons STORAGE PENDING DISPOSAL OR REUSE MID074259565
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 16.44 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Produced Fluid 3,183.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,015.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 301.01 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 522.67 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 1,540.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 181.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 265.01 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 38.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 78.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 28.33 Bbl INJECTION DISPOSAL WELL 34-119-28776
2018 CHEVRON APPALACHIA LLC Produced Fluid 73.34 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 60.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 367.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 101.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Drilling Fluid Waste 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 640.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2044642 Primary Facility 2012-02-23 Routine/Complete Inspection No Violations Noted 2/23/12 Spud inspection. No violations.
2047960 Primary Facility 2012-02-22 Drilling/Alteration No Violations Noted Horizontal Marcellus, setting conductor and cellar
2061695 Primary Facility 2012-04-09 Drilling/Alteration No Violations Noted Horizontal Marcellus, setting conductor and cellar
2063930 Primary Facility 2012-05-01 Routine/Complete Inspection No Violations Noted This was a surface inspection after a spud was called in. No issues noted.
2068987 Primary Facility 2012-05-15 Drilling/Alteration No Violations Noted Horizontal Marcellus,
2070087 Primary Facility 2012-05-22 Drilling/Alteration No Violations Noted 5/22/2012 Patterson rig rigging up on pad.
2077490 Primary Facility 2012-06-08 Drilling/Alteration No Violations Noted 6/8/2012 Patterson drilling the 4H.
2136901 Primary Facility 2013-02-01 Routine/Complete Inspection No Violations Noted no violations noted
2138407 Primary Facility 2013-02-12 Routine/Complete Inspection No Violations Noted Routine inspection. No issues noted.
2170266 Primary Facility 2013-05-30 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The well apparatus and brine tanks located on site appear to be sound condition. The erosion and sedimentation plan was located onsite and appears to be implemented as designed. The Associate BMPS appear to be properly installed and maintained. No accelerated erosion and sedimentation observed in relation to the access road or well pad area at the time of inspection. The pit located onsite appears to be in sound condition and had the required 2' of freeboard. The Department suggests the operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained.
2195281 Primary Facility 2013-08-14 Administrative/File Review Viol(s) Noted & Immediately Corrected Administrative review the result of a restoration extension request submitted to the Department on June 7 2013. During the restoration review process the Department notes that the Operator was approximately 2 months past the restoration date, when the restoration extension was filed with the Department. According to the well record submitted to the Department by the Operator the well was drilled to total depth on 5/14/2012 making the restoration date 2/14/2013, the subsequent violation is for the failure to restore the site within 9 months or file for a site restoration extension within the same time frame.
2358386 Primary Facility 2015-04-06 Site Restoration No Violations Noted Inspection in response to a "Well Site Restoration Report" filed by the Operator on 10-28-2015. At the time of inspection all earth disturbance activities, authorized by the well permit were complete, and the site has been stabilized. Site appears to meet PCSM and BMPs have been removed.
2393443 Primary Facility 2015-07-21 Routine/Complete Inspection No Violations Noted 7/21/2015 GPUs and produced fluids tanks dyked. Inspecred w/OGI P. Wyrwas.
2571261 Primary Facility 2017-03-13 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tagged. Well apparatus, brine tanks, and gas production units appear to in sound condition. No accelerated erosion or sedimentation observed on well site or access road.
2828535 Primary Facility 2019-01-17 Routine/Complete Inspection No Violations Noted Well appears to be in good working condition.
2840372 Primary Facility 2019-02-11 Complaint Inspection In Compliance with Policy RTPT inspection due to snow cover and lack of access.

At time of inspection access road and site snow-covered. Site surrounded by security fence. Well appears equipped for production. Three brine tanks on site.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2195281 675159 08/14/2013 2013-08-14 206C - Failure to restore well site within nine months after completion of drilling, failure to remove all pits, drilling supplies and equipment not needed for production. Administrative 3216c

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
675159 300893 NOV - Notice of Violation Comply/Closed 2013-10-11
675159 309503 CACP - Consent Assessment of Civil Penalty Comply/Closed 2014-04-07 2014-04-07 $2,000.00 $2,000.00

For data sources see[8]

References