37-129-28804

Well Details

Well ID: 37-129-28804
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: South Huntingdon Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149234
Farm/Lease Name: SABATINE-SMOUSE UNIT 1H
License Status:
Spud Date:
Permit Date: 2012-12-07
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.213222
Longitude: -79.706453

For data sources see[1][2][3]

Well History

Date Event
2012-12-07 New Permit Application
2013-01-24 Performed Spud Operation
2013-07-11 Drilling Completion
2013-10-23 Perforation
2016-03-31 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-23 2013-10-25 7,742 4,239,750

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Proppant US Sand Co Proppant Crystalline Silica 14808-60-7 100 8.66 0
Clean Volume Chevron Applachia, LLC Carrier/Base Fluid H20 7732-18-5 100 91.33 0
GBL Clearwater Gel Breaker Ethylene Glycol 107-21-1 60 0.00000868 0
15% Hcl Acid Reagent/PPG Used to open perfs Hydrochloric Acid 7647-01-0 15 0.00954237 0
Scale Inhibitor A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00075576 0
CMHPG Ashland Water Viscosifier Carboxymethyl Hydroxporoyl Guar Blend 68130-15-4 100 0.00056885 0
Iron Control A Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00071283 0
Unislik ST 50 CESI Friction Reducer Hydrotreated Light Distillite 64742-47-8 30 0.00340537 0
EC 6116a Nalco Biocide Dibromoacetonitrile 3252-43-5 5 0.00012821 0
Polyethylene Glycol 25322-68-3 60 0.00153848 0
1, 1-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00076924 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 621,222.00 212 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 593,966.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 407,480.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 310,067.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 256,901.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 190,876.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CHEVRON APPALACHIA LLC Drill Cuttings 983.76 Tons LANDFILL 100592
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,364.20 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 6,202.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,992.34 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,458.33 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 9.05 Tons LANDFILL 100663
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 31.33 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 37,782.33 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 86.66 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565
2014 CHEVRON APPALACHIA LLC Drill Cuttings 1.25 Tons LANDFILL 100592
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,187.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 479.69 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 531.67 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 110.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 229.33 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 74.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 188.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 38.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 378.32 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 524.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 566.66 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 40.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2134599 Primary Facility 2013-01-24 Drilling/Alteration No Violations Noted Horiaontal Marcellus
2134656 Primary Facility 2013-01-25 Drilling/Alteration No Violations Noted Horiaontal Marcellus
2148871 Primary Facility 2013-03-18 Routine/Complete Inspection No Violations Noted E&S inspection. Blue-White water found in the drill cuttyings pit.
2164816 Primary Facility 2013-04-23 Drilling/Alteration No Violations Noted 4/23/2013 keane rig drilling on the 3H.
2166017 Primary Facility 2013-05-13 Routine/Complete Inspection Pending At the time of inspection the drill rig was onsite and placed on containment. The erosion and sedimentation plan was onsite, however the department notes several areas surrounding the well pad, on the fill side of the pad that need routine maintenance, specifically regraded seeded and mulched. the Department observed multiple areas that accelerated erosion cut channels and is transporting sediment toward the LOD and perimeter controls. The perimeter controls appear to sound however the areas contributing to the accelerated erosion are in need of attention. The Department suggest the Operator address the erosion channels and regrade, seed and mulch the affected areas. The various pit located onsite appear to be in sound condition and appear to have the required 2' of freeboard. The Department also suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site maintained.
2166019 Primary Facility 2013-05-14 Follow-up Inspection Pending Follow up inpsection and meeting onsite with Operator in response to phone call regarding the previous days inspection. The Operator and Department inspected the site and the Operator agreed to address the affected areas. The Department notes that the Operator request of a two week time frame to begin work bacause the issues noted were currently not in danger of over topping permiter BMPs. The Department aggreed to a two week time frame and request a phone call notification the day work would begin.
2167512 Primary Facility 2013-05-14 Drilling/Alteration No Violations Noted 5/14/2013 Keane rig skidding from 2-H
2189370 Primary Facility 2013-07-18 Drilling/Alteration No Violations Noted 7/18/2013 Keane rig drilling on the 2H well.
2194944 Primary Facility 2013-08-06 Drilling/Alteration No Violations Noted 8/6/2013 moving rig off of pad.
2216367 Primary Facility 2013-10-24 Routine/Complete Inspection No Violations Noted At the time of inspection the well was in the process of bring stimulated. The E&S plan was onsite and appeared to be installed as outlined in the plan. No sign of accelerated erosion and sedimentation in relation to the well pad or access road at the time of inspection. The Department notes that the drill pit located onsite has been back filled and the stock pile from which the material came to backfill the pit has been hydro seeded and appears to be stable. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2228545 Primary Facility 2013-11-11 Routine/Complete Inspection No Violations Noted At the time of inspection the well was stimulated. The E&S plan was onsite and appeared to be installed as outlined in the plan. No sign of accelerated erosion and sedimentation in relation to the well pad or access road at the time of inspection. The Department also suggests the Operator add the approved OG071 to the mail box on site. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2272549 Primary Facility 2014-05-21 Routine/Complete Inspection No Violations Noted At the time of inspection well appeared to be drilled, stimulated and equipped for production. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2326218 Primary Facility 2014-11-25 Routine/Complete Inspection No Violations Noted At the time of inspection well appeared to be drilled, stimulated and equipped for production. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The Operator appeared to be in the process of backfilling the flow back pit located onsite. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2377829 Primary Facility 2015-06-10 Routine/Complete Inspection No Violations Noted 6/10/2015 Reclaiming pad, produced fluids tanks diked and GPU's.
2378648 Primary Facility 2015-06-11 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. Operator was in the process of restoring the site. Perimeter controls appear to be functioning properly.
2501329 Primary Facility 2016-07-14 Site Restoration No Violations Noted Inspection in response to a "Well Site Restoration Report" received by the Department on 3/14/2016, at the time of inspection all earth disturbance activities were complete, PCSM BMP’s installed and functioning.
2516779 Primary Facility 2016-08-31 Routine/Partial Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tank appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. DEP personnel on site during inspection Donna Davis and Sam Steingrabe and Also see inspection # 2516776 for additional observation related to the ESCGP. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2521148 Primary Facility 2016-09-20 Routine/Partial Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tank appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. DEP personnel on site during inspection Donna Davis and Sam Steingrabe and Also see inspection # 2521146 for additional observation related to the ESCGP. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2538191 Primary Facility 2016-11-08 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tank appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. Also see inspection # 2538185 for additional observation related to the ESCGP. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2543516 Primary Facility 2016-12-08 Routine/Partial Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tank appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. Also see inspection # 2543509 for additional observation related to the ESCGP. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2642995 Primary Facility 2017-10-03 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tag present. Well apparatus and brine tank appear to be in sound condition. No accelerated erosion or sedimentation observed on well site or access road. No evidence that suggests a release of production fluid.
2772298 Primary Facility 2018-08-21 Complaint Inspection No Violations Noted Inspection in response to complaint. At the time of inspection well equipped for production. Brine tanks within secondary containment and appears structurally sound. Inspection conducted during and following a precipitation event. Precipitation runoff appears to be flowing into designated basin on site. Basin appears to be functioning as designed. Areas surrounding well site permanently stabilized with no evidence of erosion. No E&S issues were observed on site and/or on access road. - Invalid Complaint Id. - 0
2845739 Primary Facility 2019-02-22 Complaint Inspection No Violations Noted Multi-well site (photo #2).

At time of inspection well appears equipped for production. Well pad surrounded by security fence. Two brine tanks on site.

For data sources see[8]

References