37-129-28806

Well Details

Well ID: 37-129-28806
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: South Huntingdon Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149234
Farm/Lease Name: SABATINE-SMOUSE UNIT 3H
License Status:
Spud Date:
Permit Date: 2012-09-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.213142
Longitude: -79.706469

For data sources see[1][2][3]

Well History

Date Event
2012-09-13 New Permit Application
2013-01-24 Performed Spud Operation
2013-08-02 Drilling Completion
2013-10-11 Perforation
2016-03-30 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-11 2013-10-16 8,088 4,239,450

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Clean Volume Chevron Applachia, LLC Carrier/Base Fluid H20 7732-18-5 100 92.72 0
Iron Control A Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00007089 0
Unislik ST 50 CESI Friction Reducer Hydrotreated Light Distillite 64742-47-8 30 0.00031497 0
GBL Clearwater Gel Breaker Ethylene Glycol 107-21-1 60 0.00000045 0
EC 6116a Nalco Biocide 1, 1-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00015329 0
Dibromoacetonitrile 3252-43-5 5 0.00001277 0
Polyethylene Glycol 25322-68-3 60 0.00015329 0
CMHPG Ashland Water Viscosifier Carboxymethyl Hydroxporoyl Guar Blend 68130-15-4 100 0.00002919 0
15% Hcl Acid Reagent/PPG Used to open perfs Hydrochloric Acid 7647-01-0 15 0.0008626 0
Scale Inhibitor A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00007571 0
Proppant US Sand Co Proppant Crystalline Silica 14808-60-7 100 8.66 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 891,237.00 212 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 921,971.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 621,939.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 473,049.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 404,731.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 329,666.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CHEVRON APPALACHIA LLC Drill Cuttings 983.77 Tons LANDFILL 100592
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 6,202.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,986.40 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,992.34 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,458.33 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 9.05 Tons LANDFILL 100663
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 31.33 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 37,782.33 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 86.66 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565
2014 CHEVRON APPALACHIA LLC Drill Cuttings 1.25 Tons LANDFILL 100592
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,187.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 479.69 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 531.67 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 110.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 226.34 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 74.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 188.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 38.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 263.32 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 409.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 566.66 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 40.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2134614 Primary Facility 2013-01-24 Drilling/Alteration No Violations Noted Horiaontal Marcellus
2134653 Primary Facility 2013-01-25 Routine/Complete Inspection No Violations Noted Horiaontal Marcellus
2148867 Primary Facility 2013-03-19 Routine/Complete Inspection No Violations Noted Routine E&S inspection. Blue-White water found in the drill cuttyings pit
2164824 Primary Facility 2013-02-23 Drilling/Alteration No Violations Noted 4/23/2013 Keane rig drilling at depth of 5515'.
2166026 Primary Facility 2013-05-13 Routine/Complete Inspection No Violations Noted At the time of inspection the drill rig was on site and placed on containment. The erosion and sedimentation plan was on site. The various pit located onsite appear to be in sound condition and had the required 2' of freeboard. The Department suggest the Operator continue to inspect the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2167527 Primary Facility 2013-05-14 Drilling/Alteration No Violations Noted 5/14/2013 Keane rig skidding to the 1H
2183275 Primary Facility 2013-07-10 Complaint Inspection No Violations Noted Inspection the result of a complaint received by the Department on 7/10/2013 at approximately 1:00pm. The adjacent landowners issue stems from excessive runoff water on the property after a significant precipitation event. At the time of inspection the Department observed saturated ground behind the complainant home and garage, also observed were traces of sediment deposits. Upon further inspection of the well site the Department observed a compromised silt sox BMP directly behind the complainants home and garage. The Department notes that this was most likely the reason and source of the excess water. The Department suggests the Operator submit metrological/rain fall data for July 10 2013. The Department suggest that the Operator also submit weekly site inspections reports from 6/10/2013 to the date of this incident for the Departments review.
2189372 Primary Facility 2013-07-18 Drilling/Alteration No Violations Noted 7/18/2013 sidewinder rig drilling on the 2H.
2194953 Primary Facility 2013-08-06 Drilling/Alteration No Violations Noted 8/6/2013 moving rig off of pad.
2197076 Primary Facility 2013-08-19 Routine/Complete Inspection No Violations Noted Follow-up inspection from a complaint filed with the Department on 7/10/2013. During the inspection the Department observed several areas that the Operator fixed following the precipitation events in July. The Department notes that the Operator has filed meteorological data supporting the extreme rainfall event on July 10 2013, which resulted in the BMP failure noted in the July 10 2013 inspection. At the time of inspection the well appeared to be drilled, however the wells don’t appear to be in production.
2216370 Primary Facility 2013-10-24 Routine/Complete Inspection No Violations Noted At the time of inspection the well was in the process of bring stimulated. The E&S plan was onsite and appeared to be installed as outlined in the plan. No sign of accelerated erosion and sedimentation in relation to the well pad or access road at the time of inspection. The Department notes that the drill pit located onsite has been back filled and the stock pile from which the material came to backfill the pit has been hydro seeded and appears to be stable. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2228551 Primary Facility 2013-11-11 Routine/Complete Inspection No Violations Noted At the time of inspection the well was stimulated. The E&S plan was onsite and appeared to be installed as outlined in the plan. No sign of accelerated erosion and sedimentation in relation to the well pad or access road at the time of inspection. The Department also suggests the Operator add the approved OG071 to the mail box on site. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2272552 Primary Facility 2014-05-21 Routine/Complete Inspection No Violations Noted At the time of inspection well appeared to be drilled, stimulated and equipped for production. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2326220 Primary Facility 2014-11-25 Routine/Complete Inspection No Violations Noted At the time of inspection well appeared to be drilled, stimulated and equipped for production. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The Operator appeared to be in the process of backfilling the flow back pit located onsite. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2377834 Primary Facility 2015-06-10 Routine/Complete Inspection No Violations Noted 6/10/2015 Reclaiming pad, produced fluids tanks diked and GPU's.
2378638 Primary Facility 2015-06-11 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. Operator was in the process of restoring the site. Perimeter controls appear to be functioning properly.
2501334 Primary Facility 2016-07-14 Site Restoration No Violations Noted Inspection in response to a "Well Site Restoration Report" received by the Department on 3/14/2016, at the time of inspection all earth disturbance activities were complete, PCSM BMP’s installed and functioning.
2516784 Primary Facility 2016-08-31 Routine/Partial Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tank appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. DEP personnel on site during inspection Donna Davis and Sam Steingrabe and Also see inspection # 2516776 for additional observation related to the ESCGP. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2521150 Primary Facility 2016-09-20 Routine/Partial Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tank appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. DEP personnel on site during inspection Donna Davis and Sam Steingrabe and Also see inspection # 2521146 for additional observation related to the ESCGP. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2538195 Primary Facility 2016-11-08 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tank appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. Also see inspection # 2538185 for additional observation related to the ESCGP. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2543528 Primary Facility 2016-12-08 Routine/Partial Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tank appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. Also see inspection # 2543509 for additional observation related to the ESCGP. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2642999 Primary Facility 2017-10-03 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tag present. Well apparatus and brine tank appear to be in sound condition. No accelerated erosion or sedimentation observed on well site or access road. No evidence that suggests a release of production fluid.
2772308 Primary Facility 2018-08-21 Complaint Inspection No Violations Noted Inspection in response to complaint. At the time of inspection well equipped for production. Brine tanks within secondary containment and appears structurally sound. Inspection conducted during and following a precipitation event. Precipitation runoff appears to be flowing into designated basin on site. Basin appears to be functioning as designed. Areas surrounding well site permanently stabilized with no evidence of erosion. No E&S issues were observed on site and/or on access road. - Invalid Complaint Id. - 0
2845748 Primary Facility 2019-02-22 Complaint Inspection No Violations Noted Multi-well site (photo #2).

At time of inspection well appears equipped for production. Well pad surrounded by security fence. Two brine tanks on site.

For data sources see[8]