37-129-28836

Well Details

Well ID: 37-129-28836
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: South Huntingdon Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 144860
Farm/Lease Name: REAMER UNIT 9H
License Status:
Spud Date:
Permit Date: 2013-02-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.230056
Longitude: -79.743889

For data sources see[1][2][3]

Well History

Date Event
2013-02-11 New Permit Application
2013-04-17 Performed Spud Operation
2014-03-22 Drilling Completion
2016-06-14 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-11-17 2014-11-22 7,875 4,499,410

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 15% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 15 0.00911496 0
B466 Schlumberger Friction Reducer Distillates (petroleum), hydrotreated light 64742-47-8 30 0.00333919 0
Ammonium Acetate 631-61-8 6 0.00066784 0
Alcohol Ethoxylates Proprietary 5 0.00055653 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 8.12037 0
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00031279 0
Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 91.7301 0
J580 Schlumberger Gelling Agent, Water Carbohydrate Polymer Proprietary 100 0.0230571 0
EC6673W Nalco Iron Control Ethylene Glycol 107-21-1 30 0.0007818 0
J134 Schlumberger Gel Breaker Hemicellulase enzyme 9012-54-8 100 0.00112158 0
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00082705 0
A264 Schlumberger Corrosion Inhibitor Aliphatic acids Proprietary 30 0.00003273 0
Prop-2-yn-1-ol 107-19-7 10 0.00001091 0
Methanol 67-56-1 40 0.00004363 0
Aliphatic alcohols, ethoxylayed #1 Proprietary 30 0.00003273 0
EC6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00076652 0
Polyethylene Glycol 25322-68-3 60 0.00153303 0
Dibromoacetonitrile 3252-43-5 5 0.00012775 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 147,549.00 150 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 215,217.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 165,139.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 125,803.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 100,116.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CHEVRON APPALACHIA LLC Drill Cuttings 354.36 Tons LANDFILL 100592
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,558.30 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 1,199.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 3,108.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,519.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 46.67 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 6,210.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Drill Cuttings 382.49 Tons LANDFILL 100592
2014 CHEVRON APPALACHIA LLC Drill Cuttings 48.67 Tons LANDFILL 100663
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 8.45 Tons LANDFILL 100592
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,515.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 16,041.33 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 3,836.65 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 9.72 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2016 CHEVRON APPALACHIA LLC Produced Fluid 1,441.74 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 2,752.68 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 6,506.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 139.45 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 335.00 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 646.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 149.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste 37.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 63.34 Bbl INJECTION DISPOSAL WELL 34-119-28776
2018 CHEVRON APPALACHIA LLC Produced Fluid 294.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 37.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 576.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 75.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 43.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 796.66 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 40.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2149689 Primary Facility 2013-03-20 Routine/Complete Inspection No Violations Noted Routine inspection. Signed off on a minor E&S modification. No isssues noted.
2156623 Primary Facility 2013-04-15 Complaint Inspection In Compliance with Policy This was a complaint inspection. Met with Chevron and complainant. Chevron resolved the issues that the complainant had with them.
2159056 Primary Facility 2013-04-17 Follow-up Inspection No Violations Noted Followup inspection to see if new sump pump worked after a rain event.
2165099 Primary Facility 2013-05-09 Routine/Complete Inspection No Violations Noted At the time of inspection the drill rig was onsite, and placed on secondary containment. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2167537 Primary Facility 2013-04-18 Drilling/Alteration No Violations Noted Conductor & cellar set
2189049 Primary Facility 2013-08-05 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled to KOP. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2241182 Primary Facility 2014-01-31 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled to KOP. The Erosion and Sedimentation Plan was on site. Unable to inspection condition of E&S controls due to snow cover. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2321903 Primary Facility 2014-11-17 Routine/Complete Inspection No Violations Noted At the time of inspection the Operator was actively stimulating wells located on site. The Operator submitted a Restoration Request on 10/15/2014. During the inspection the well site appeared to be in stable condition. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The E&S plan was located on site and appeared to properly installed. The Department grants the restoration extension to the requested date of 12/20/2016. The Department also suggests the Operator continue to monitor the site weekly and after significant precipitation events.
2337578 Primary Facility 2015-01-22 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drilled and stimulated, however not equipped for production. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The E&S plan was located on site and appeared to properly installed. The Department also suggests the Operator continue to monitor the site weekly and after significant precipitation events.
2376310 Primary Facility 2015-06-04 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The brine tanks and gas production units appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2433185 Primary Facility 2015-12-15 Routine/Partial Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The brine tanks and gas production units appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2433215 Primary Facility 2015-12-15 Routine/Partial Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The brine tanks and gas production units appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2470510 Primary Facility 2016-03-31 Routine/Partial Inspection No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The brine tanks and gas production units appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2569114 Primary Facility 2017-03-08 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tagged. Well apparatus, brine tank and gas production unit appears to be in sound condition. No accelerated erosion or sedimentation observed on the well site or access road.
2629611 Primary Facility 2017-08-28 Site Restoration No Violations Noted Well drilled and equipped for production. Well apparatus, brine tank, and gas production unit appeared to be in sound condition. Also see inspection report #262907 for additional comments associated with earth disturbance permit associated with the well site.
2671264 Primary Facility 2017-12-01 Site Restoration No Violations Noted Inspection in response to receipt of Post-Drilling Well Site Restoration Report. At the time of inspection well appears equipped for production. Site restored. No E&S issues. Restoration report approved.

For data sources see[8]

References