If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
| Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 34-151-23403 | | Well ID: 34-151-23403 | ||
| − | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40. | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.75149632, -81.14863125 | width=100% | height=100% }} |
|- | |- | ||
| − | | County: | + | | County: [[Stark County, Ohio|Stark]] |
|- | |- | ||
| − | | Municipality: | + | | Municipality: |
|- | |- | ||
| − | | Operator Name: | + | | Operator Name: [[PDL SERVICES INC]] |
|- | |- | ||
| − | | Well Pad ID: | + | | Well Pad ID: |
|- | |- | ||
| − | | Farm/Lease Name: | + | | Farm/Lease Name: |
|- | |- | ||
| − | | First Permit Date: | + | | First Permit Date: |
|- | |- | ||
| − | | Last Permit Date: | + | | Last Permit Date: |
|- | |- | ||
| Spud Date: 1980-12-18 | | Spud Date: 1980-12-18 | ||
|- | |- | ||
| − | | Unconventional: | + | | Unconventional: No |
|- | |- | ||
| − | | | + | | Configuration: Vertical |
|- | |- | ||
| − | | Producing | + | | Well Status: Producing |
|- | |- | ||
| − | | Violations: | + | | Violations: 0 |
|- | |- | ||
| − | | Latitude: 40. | + | | Latitude: 40.75149632 |
|- | |- | ||
| − | | Longitude: -81. | + | | Longitude: -81.14863125 |
|- | |- | ||
|} | |} | ||
| Line 43: | Line 43: | ||
!scope="col" | OIL QUANTITY | !scope="col" | OIL QUANTITY | ||
!scope="col" | OIL PRODUCTION DAYS | !scope="col" | OIL PRODUCTION DAYS | ||
| + | |- | ||
| + | | 1984-0 | ||
| + | | style="text-align:right;" | 1514.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 465.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 1988-0 | ||
| + | | style="text-align:right;" | 766.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 313.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 1989-0 | ||
| + | | style="text-align:right;" | 3289.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 1208.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 1990-0 | ||
| + | | style="text-align:right;" | 747.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 317.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 1991-0 | ||
| + | | style="text-align:right;" | 428.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 234.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 1992-0 | ||
| + | | style="text-align:right;" | 687.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 334.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 1993-0 | ||
| + | | style="text-align:right;" | 635.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 244.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 1994-0 | ||
| + | | style="text-align:right;" | 576.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 247.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 1996-0 | ||
| + | | style="text-align:right;" | 720.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 0.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 2001-0 | ||
| + | | style="text-align:right;" | 809.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 0.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 2008-0 | ||
| + | | style="text-align:right;" | 333.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 5.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 2009-0 | ||
| + | | style="text-align:right;" | 329.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 8.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 2010-0 | ||
| + | | style="text-align:right;" | 331.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 6.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 2011-0 | ||
| + | | style="text-align:right;" | 987.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 324.0 | ||
| + | | | ||
| + | |- | ||
| + | |- | ||
| + | | 2012-0 | ||
| + | | style="text-align:right;" | 974.0 | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | | style="text-align:right;" | 310.0 | ||
| + | | | ||
| + | |- | ||
|} | |} | ||
| − | + | For data sources see<ref>{{cite web | |
| − | + | | title = Ohio Department of Natural Resources RBDMS | |
| − | + | | publisher = [http://oilandgas.ohiodnr.gov/] | |
| − | + | | date = 2015-06-19 | |
| − | + | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production | |
| − | + | | accessdate = 2015-06-20 }}</ref> | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
== Inspection Data == | == Inspection Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| Line 64: | Line 193: | ||
!scope="col" | VIOLATION ID | !scope="col" | VIOLATION ID | ||
!scope="col" | VIOLATION CODE | !scope="col" | VIOLATION CODE | ||
| − | !scope="col" | | + | !scope="col" | VIOLATION COMMENT |
|- | |- | ||
| − | | | + | | 10252114 |
| − | | | + | | 2014-11-12 |
| − | | | + | | |
| − | + | | I was on location to follow up on complaint #4403. The well and tank battery have recently been worked over. A new dike, 100bbl production tank and separator have been installed where the existing tank battery stood. The lease road has been stabilized with several loads of stone and ceramic slag. A new chart has been installed in the chart box on 11-12-14 and shows that the well is producing. I have contacted PDL Services and they told me that the 2013 production reports are currently being submitted to the Division of Oil & Gas as required. | |
| − | + | | | |
| − | + | | | |
| − | + | | | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
| − | | | ||
| − | | | ||
|- | |- | ||
|- | |- | ||
| 1353000592 | | 1353000592 | ||
| 2012-11-14 | | 2012-11-14 | ||
| − | | | + | | |
| − | + | | I received an email from Dave Claus regarding a call he received from Jodi Carnahan on November 9, 2012. I inspected the Direnzo-Fimble Unit #2 well (34151234030000) on November 14, 2012; I was accompanied by Tom Hill. My inspection showed the lease road was deeply rutted and needs to be graded. The domestic gas line is not buried and runs parallel to the lease road. The line has several segments that are damaged. The wellhead includes an electric powered pumping unit. The belts on the pumping unit are burned off so the pumping unit is not functional. The rods are still polished, indicating recent activity. The tubing and 4.5 inch casing valves do not have bull plugs installed and there are no pressure gauges installed. There is oil contamination surrounding the wellhead covering an area approximately 60 square feet. There is an operator sign attached to the electrical box at the wellhead. The operator reported production of 6bbl of oil and 331 MCF of gas in 2010. There is no production posted for 2011. The tank battery consists of one 210 bbl stock tank and one mechanical separator. Fittings on the separator are leaking. A quarter inch restrictor plate is installed to the sales line. The 210 bbl stock tank has the proper operator sign attached. There is a chart installed with an installation date of November 13, 2012, showing 90 psi on the sales line and no gas production. The dike is overgrown with vegetation. The western side of the dike is eroded due to run off to the stream. The property owner, Sam Sluss, met with us at the wellhead and said he hasn | |
| − | + | | | |
| − | | | + | | |
| − | | | + | | |
| − | | | ||
|- | |- | ||
|- | |- | ||
| 1393863090 | | 1393863090 | ||
| 2014-03-03 | | 2014-03-03 | ||
| − | | | + | | |
| During my inspection I found that the lease road was stable. A yellow plastic gas line is not buried and runs parallel to the lease road. The line has several segments that are damaged. The tubing and 4.5 inch casing valves do not have bull plugs installed and there are no pressure gauges installed. There is a small oil drip from the wellhead. There is no operator sign attached to the electrical box or at the wellhead. The tank battery consists of one 210 bbl stock tank and one vertical mechanical separator. The 210 bbl stock tank has the proper operator sign attached. There is a chart installed in the chart box with an installation date of 2-26-2014 indicating production. The dike is stable and is containing the spilled oil within it and at this time no oil was detected outside the dike. There are two oil drums inside the dike next to the separator leaking oil to a spill of approximately 10' by 5'. There is a sound of liquid flowing into the 210 bbl tank. There is a oil spill next to the tank that differs in color from the oil leaking from the drums. The source of this oil could not be determined at this time due to the ice and snow in the dike. Issues for PDL Services Inc to address include; oil contamination around pump jack wellhead and inside the tank battery be cleaned up to include removal of contaminated soil, and the two leaking oil drums be removed. The yellow gas line along the lease road needs removed or repaired and properly buried. I have contacted the operator and been informed that the issues will be addressed this week. | | During my inspection I found that the lease road was stable. A yellow plastic gas line is not buried and runs parallel to the lease road. The line has several segments that are damaged. The tubing and 4.5 inch casing valves do not have bull plugs installed and there are no pressure gauges installed. There is a small oil drip from the wellhead. There is no operator sign attached to the electrical box or at the wellhead. The tank battery consists of one 210 bbl stock tank and one vertical mechanical separator. The 210 bbl stock tank has the proper operator sign attached. There is a chart installed in the chart box with an installation date of 2-26-2014 indicating production. The dike is stable and is containing the spilled oil within it and at this time no oil was detected outside the dike. There are two oil drums inside the dike next to the separator leaking oil to a spill of approximately 10' by 5'. There is a sound of liquid flowing into the 210 bbl tank. There is a oil spill next to the tank that differs in color from the oil leaking from the drums. The source of this oil could not be determined at this time due to the ice and snow in the dike. Issues for PDL Services Inc to address include; oil contamination around pump jack wellhead and inside the tank battery be cleaned up to include removal of contaminated soil, and the two leaking oil drums be removed. The yellow gas line along the lease road needs removed or repaired and properly buried. I have contacted the operator and been informed that the issues will be addressed this week. | ||
| − | | | + | | |
| − | | | + | | |
| − | | | + | | |
|- | |- | ||
|- | |- | ||
| 1395866259 | | 1395866259 | ||
| 2014-03-26 | | 2014-03-26 | ||
| − | | | + | | |
| During my inspection I found that the lease road was stable. The plastic yellow gas line has been removed. The small oil drip from the wellhead has been fixed. The tank battery consists of one 210 bbl stock tank and one vertical mechanical separator. The 210 bbl stock tank has the proper operator sign attached. The dike is stable and the spilled oil within it has been cleaned up and removed. The two oil drums have been removed from the location and are no longer present. The oil spill near the drums has been cleaned up. The compliance notice for this well regarding contamination is now closed. | | During my inspection I found that the lease road was stable. The plastic yellow gas line has been removed. The small oil drip from the wellhead has been fixed. The tank battery consists of one 210 bbl stock tank and one vertical mechanical separator. The 210 bbl stock tank has the proper operator sign attached. The dike is stable and the spilled oil within it has been cleaned up and removed. The two oil drums have been removed from the location and are no longer present. The oil spill near the drums has been cleaned up. The compliance notice for this well regarding contamination is now closed. | ||
| − | | | + | | |
| − | | | + | | |
| − | | | + | | |
|- | |- | ||
|- | |- | ||
| 50637718 | | 50637718 | ||
| 2012-12-19 | | 2012-12-19 | ||
| − | | | + | | |
| I inspected the Direnzo-Fimble Unit #2 well (34151234030000) on December 19, 2012. My inspection showed the lease road was graded and top dressed with crushed brick aggregate to the tank battery and wellhead. The domestic gas line has been removed and is not connected to the well. The belts on the pumping unit have been replaced. The tubing and 4.5 inch casing valves still do not have bull plugs installed. The oil contamination surrounding the wellhead has been remediated and neutralized with lime. Fittings on the mechanical separator are still leaking. The dike is still overgrown with vegetation. The western side of the earthen berm has been repaired to prevent the loss of fluid from the site. I spoke to Jodi Carnahan and she said the pumping unit has been operational. | | I inspected the Direnzo-Fimble Unit #2 well (34151234030000) on December 19, 2012. My inspection showed the lease road was graded and top dressed with crushed brick aggregate to the tank battery and wellhead. The domestic gas line has been removed and is not connected to the well. The belts on the pumping unit have been replaced. The tubing and 4.5 inch casing valves still do not have bull plugs installed. The oil contamination surrounding the wellhead has been remediated and neutralized with lime. Fittings on the mechanical separator are still leaking. The dike is still overgrown with vegetation. The western side of the earthen berm has been repaired to prevent the loss of fluid from the site. I spoke to Jodi Carnahan and she said the pumping unit has been operational. | ||
| − | | | + | | |
| − | | | + | | |
| − | | | + | | |
|- | |- | ||
|} | |} | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title = Ohio Department of Natural Resources RBDMS | ||
| + | | publisher = [http://oilandgas.ohiodnr.gov/] | ||
| + | | date = 2015-06-19 | ||
| + | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection | ||
| + | | accessdate = 2015-06-20 }}</ref> | ||
| + | == References == | ||
| + | {{reflist}} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Wells]] | [[Category:Wells]] | ||
| Well ID: 34-151-23403 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.75149632,"lon":-81.14863125,"icon":""}]} |
| County: Stark | |
| Municipality: | |
| Operator Name: PDL SERVICES INC | |
| Well Pad ID: | |
| Farm/Lease Name: | |
| First Permit Date: | |
| Last Permit Date: | |
| Spud Date: 1980-12-18 | |
| Unconventional: No | |
| Configuration: Vertical | |
| Well Status: Producing | |
| Violations: 0 | |
| Latitude: 40.75149632 | |
| Longitude: -81.14863125 |
| PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
|---|---|---|---|---|---|---|
| 1984-0 | 1514.0 | 465.0 | ||||
| 1988-0 | 766.0 | 313.0 | ||||
| 1989-0 | 3289.0 | 1208.0 | ||||
| 1990-0 | 747.0 | 317.0 | ||||
| 1991-0 | 428.0 | 234.0 | ||||
| 1992-0 | 687.0 | 334.0 | ||||
| 1993-0 | 635.0 | 244.0 | ||||
| 1994-0 | 576.0 | 247.0 | ||||
| 1996-0 | 720.0 | 0.0 | ||||
| 2001-0 | 809.0 | 0.0 | ||||
| 2008-0 | 333.0 | 5.0 | ||||
| 2009-0 | 329.0 | 8.0 | ||||
| 2010-0 | 331.0 | 6.0 | ||||
| 2011-0 | 987.0 | 324.0 | ||||
| 2012-0 | 974.0 | 310.0 |
For data sources see[1]
| INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
|---|---|---|---|---|---|---|
| 10252114 | 2014-11-12 | I was on location to follow up on complaint #4403. The well and tank battery have recently been worked over. A new dike, 100bbl production tank and separator have been installed where the existing tank battery stood. The lease road has been stabilized with several loads of stone and ceramic slag. A new chart has been installed in the chart box on 11-12-14 and shows that the well is producing. I have contacted PDL Services and they told me that the 2013 production reports are currently being submitted to the Division of Oil & Gas as required. | ||||
| 1353000592 | 2012-11-14 | I received an email from Dave Claus regarding a call he received from Jodi Carnahan on November 9, 2012. I inspected the Direnzo-Fimble Unit #2 well (34151234030000) on November 14, 2012; I was accompanied by Tom Hill. My inspection showed the lease road was deeply rutted and needs to be graded. The domestic gas line is not buried and runs parallel to the lease road. The line has several segments that are damaged. The wellhead includes an electric powered pumping unit. The belts on the pumping unit are burned off so the pumping unit is not functional. The rods are still polished, indicating recent activity. The tubing and 4.5 inch casing valves do not have bull plugs installed and there are no pressure gauges installed. There is oil contamination surrounding the wellhead covering an area approximately 60 square feet. There is an operator sign attached to the electrical box at the wellhead. The operator reported production of 6bbl of oil and 331 MCF of gas in 2010. There is no production posted for 2011. The tank battery consists of one 210 bbl stock tank and one mechanical separator. Fittings on the separator are leaking. A quarter inch restrictor plate is installed to the sales line. The 210 bbl stock tank has the proper operator sign attached. There is a chart installed with an installation date of November 13, 2012, showing 90 psi on the sales line and no gas production. The dike is overgrown with vegetation. The western side of the dike is eroded due to run off to the stream. The property owner, Sam Sluss, met with us at the wellhead and said he hasn | ||||
| 1393863090 | 2014-03-03 | During my inspection I found that the lease road was stable. A yellow plastic gas line is not buried and runs parallel to the lease road. The line has several segments that are damaged. The tubing and 4.5 inch casing valves do not have bull plugs installed and there are no pressure gauges installed. There is a small oil drip from the wellhead. There is no operator sign attached to the electrical box or at the wellhead. The tank battery consists of one 210 bbl stock tank and one vertical mechanical separator. The 210 bbl stock tank has the proper operator sign attached. There is a chart installed in the chart box with an installation date of 2-26-2014 indicating production. The dike is stable and is containing the spilled oil within it and at this time no oil was detected outside the dike. There are two oil drums inside the dike next to the separator leaking oil to a spill of approximately 10' by 5'. There is a sound of liquid flowing into the 210 bbl tank. There is a oil spill next to the tank that differs in color from the oil leaking from the drums. The source of this oil could not be determined at this time due to the ice and snow in the dike. Issues for PDL Services Inc to address include; oil contamination around pump jack wellhead and inside the tank battery be cleaned up to include removal of contaminated soil, and the two leaking oil drums be removed. The yellow gas line along the lease road needs removed or repaired and properly buried. I have contacted the operator and been informed that the issues will be addressed this week. | ||||
| 1395866259 | 2014-03-26 | During my inspection I found that the lease road was stable. The plastic yellow gas line has been removed. The small oil drip from the wellhead has been fixed. The tank battery consists of one 210 bbl stock tank and one vertical mechanical separator. The 210 bbl stock tank has the proper operator sign attached. The dike is stable and the spilled oil within it has been cleaned up and removed. The two oil drums have been removed from the location and are no longer present. The oil spill near the drums has been cleaned up. The compliance notice for this well regarding contamination is now closed. | ||||
| 50637718 | 2012-12-19 | I inspected the Direnzo-Fimble Unit #2 well (34151234030000) on December 19, 2012. My inspection showed the lease road was graded and top dressed with crushed brick aggregate to the tank battery and wellhead. The domestic gas line has been removed and is not connected to the well. The belts on the pumping unit have been replaced. The tubing and 4.5 inch casing valves still do not have bull plugs installed. The oil contamination surrounding the wellhead has been remediated and neutralized with lime. Fittings on the mechanical separator are still leaking. The dike is still overgrown with vegetation. The western side of the earthen berm has been repaired to prevent the loss of fluid from the site. I spoke to Jodi Carnahan and she said the pumping unit has been operational. |