Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-151-21261
 
| Well ID: 34-151-21261
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.7930055684, -81.3020235566 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.79300557, -81.30202356 | width=100% | height=100% }}  
 
|-
 
|-
| County:
+
| County: [[Stark County, Ohio|Stark]]
 
|-
 
|-
| Municipality:
+
| Municipality:  
 
|-
 
|-
| Operator Name:
+
| Operator Name: [[G & O RESOURCES LTD]]
 
|-
 
|-
| Well Pad ID:
+
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:
+
| Farm/Lease Name:  
 
|-
 
|-
| First Permit Date:
+
| First Permit Date:  
 
|-
 
|-
| Last Permit Date:
+
| Last Permit Date:  
 
|-
 
|-
 
| Spud Date: 1967-07-28
 
| Spud Date: 1967-07-28
 
|-
 
|-
| Unconventional:
+
| Unconventional: No
 
|-
 
|-
| Horizontal:
+
| Configuration: Vertical
 
|-
 
|-
| Producing: No
+
| Well Status: Plugged and Abandoned
 
|-
 
|-
| Violations: 3
+
| Violations: 0
 
|-
 
|-
| Latitude: 40.7930055684
+
| Latitude: 40.79300557
 
|-
 
|-
| Longitude: -81.3020235566
+
| Longitude: -81.30202356
 
|-
 
|-
 
|}
 
|}
Line 43: Line 43:
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
!scope="col" | OIL PRODUCTION DAYS
 +
|-
 +
| 1984-0
 +
| style="text-align:right;" | 522.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 328.0
 +
|
 +
|-
 +
|-
 +
| 1987-0
 +
| style="text-align:right;" | 769.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 191.0
 +
|
 +
|-
 +
|-
 +
| 1988-0
 +
| style="text-align:right;" | 517.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 164.0
 +
|
 +
|-
 +
|-
 +
| 1989-0
 +
| style="text-align:right;" | 290.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 212.0
 +
|
 +
|-
 +
|-
 +
| 1990-0
 +
| style="text-align:right;" | 694.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 191.0
 +
|
 +
|-
 +
|-
 +
| 1991-0
 +
| style="text-align:right;" | 627.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 202.0
 +
|
 +
|-
 +
|-
 +
| 1992-0
 +
| style="text-align:right;" | 772.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 200.0
 +
|
 +
|-
 +
|-
 +
| 1993-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 104.0
 +
|
 +
|-
 +
|-
 +
| 1994-0
 +
| style="text-align:right;" | 294.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 195.0
 +
|
 +
|-
 +
|-
 +
| 1995-0
 +
| style="text-align:right;" | 247.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 180.0
 +
|
 +
|-
 +
|-
 +
| 1996-0
 +
| style="text-align:right;" | 608.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 287.0
 +
|
 +
|-
 +
|-
 +
| 1997-0
 +
| style="text-align:right;" | 352.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 90.0
 +
|
 +
|-
 +
|-
 +
| 1998-0
 +
| style="text-align:right;" | 565.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 212.0
 +
|
 +
|-
 +
|-
 +
| 1999-0
 +
| style="text-align:right;" | 493.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 151.0
 +
|
 +
|-
 +
|-
 +
| 2000-0
 +
| style="text-align:right;" | 451.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 144.0
 +
|
 +
|-
 +
|-
 +
| 2001-0
 +
| style="text-align:right;" | 345.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 183.0
 +
|
 +
|-
 +
|-
 +
| 2002-0
 +
| style="text-align:right;" | 247.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 88.0
 +
|
 +
|-
 +
|-
 +
| 2003-0
 +
| style="text-align:right;" | 321.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 142.0
 +
|
 +
|-
 +
|-
 +
| 2004-0
 +
| style="text-align:right;" | 47.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 135.0
 +
|
 +
|-
 +
|-
 +
| 2005-0
 +
| style="text-align:right;" | 23.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 146.0
 +
|
 +
|-
 +
|-
 +
| 2006-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 47.0
 +
|
 +
|-
 +
|-
 +
| 2007-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 161.0
 +
|
 +
|-
 +
|-
 +
| 2008-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 86.0
 +
|
 +
|-
 +
|-
 +
| 2009-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 2010-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 31.0
 +
|
 +
|-
 +
|-
 +
| 2011-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 2012-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 2013-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 
|}
 
|}
== Waste Data ==
+
For data sources see<ref>{{cite web
{| class="wikitable sortable" width="95%"
+
| title = Ohio Department of Natural Resources RBDMS
!scope="col" | PERIOD
+
| publisher = [http://oilandgas.ohiodnr.gov/]
!scope="col" | TYPE
+
| date = 2015-06-19
!scope="col" | QUANTITY
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
!scope="col" | UNITS
+
| accessdate = 2015-06-20 }}</ref>
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
|}
 
 
== Inspection Data ==
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 64: Line 310:
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION CODE
!scope="col" | VIOLATION_COMMENT
+
!scope="col" | VIOLATION COMMENT
 
|-
 
|-
 
| 1398095295
 
| 1398095295
 
| 2014-04-21
 
| 2014-04-21
|
+
|  
 
| I was on location to perform an inspection of this well regarding complaint #4668. During my inspection I found a graveled lease road that is used as a residential driveway. The tank battery consists of two empty 210 bbls production tanks and a vertical separator, all within an earthen dike. The tank battery and well have an I.D. sign present but it is not legible. The pump jack well does not have the required shroud around the drive belts and electric motor. There is a house gas connection on the well but it is not currently functioning. I have contacted the operator and informed them of the issues. This well is currently on the G&O Resources plugging list when plugging funds are available. The only production shown for this well since 2009 is 31 barrels of oil produced in 2010. This well shall be plugged with 180 days as required by ORC 1509.12B.
 
| I was on location to perform an inspection of this well regarding complaint #4668. During my inspection I found a graveled lease road that is used as a residential driveway. The tank battery consists of two empty 210 bbls production tanks and a vertical separator, all within an earthen dike. The tank battery and well have an I.D. sign present but it is not legible. The pump jack well does not have the required shroud around the drive belts and electric motor. There is a house gas connection on the well but it is not currently functioning. I have contacted the operator and informed them of the issues. This well is currently on the G&O Resources plugging list when plugging funds are available. The only production shown for this well since 2009 is 31 barrels of oil produced in 2010. This well shall be plugged with 180 days as required by ORC 1509.12B.
|
+
|  
| 9-9-02
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
| 1398095295
+
| 1413304733
| 2014-04-21
+
| 2014-10-14
|
+
|  
| I was on location to perform an inspection of this well regarding complaint #4668. During my inspection I found a graveled lease road that is used as a residential driveway. The tank battery consists of two empty 210 bbls production tanks and a vertical separator, all within an earthen dike. The tank battery and well have an I.D. sign present but it is not legible. The pump jack well does not have the required shroud around the drive belts and electric motor. There is a house gas connection on the well but it is not currently functioning. I have contacted the operator and informed them of the issues. This well is currently on the G&O Resources plugging list when plugging funds are available. The only production shown for this well since 2009 is 31 barrels of oil produced in 2010. This well shall be plugged with 180 days as required by ORC 1509.12B.
+
| I was on location to check the status of Steve Hagen Well Service plugging this well. The rig is on location and the area is being lined with plastic. The plugging of the well and the plug schedule was discussed and it was decided plugs would be set through tubing due to concerns with 4.5 diameter production casing integrity. They will pull rods today and prepare to cement tomorrow 10-15-2014.
|
+
|
| 9-9-05(A)10
+
|
|
+
|
 +
|-
 +
|-
 +
| 1413893168
 +
| 2014-10-16
 +
|
 +
| On 10/16/2014, I was on location to witness Hagen Well Service plug the well for G & O Resources.  PetroSet Cementing Services was cementing contractor.  First, Hagen ran 2.375
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| 1427900506
 +
| 2015-04-01
 +
|
 +
| I was on location to follow up to complaint #4668. No additional restoration work has been conducted on this well since the last inspection on 1/23/2015. The 6 month timeframe for final restoration will be on 4/20/2015. Currently the power poles, concrete base for the separator, lease road and ruts in the straw covered ground are present. These issue must be addressed before restoration will be passed.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| 1430919431
 +
| 2015-05-05
 +
|
 +
| I was on the location with the landowner and Ron of Lakeside to agree upon the final restoration for this well. The power poles will be pulled from the ground and left on location for a contractor to remove. The concrete pad for the separator will be removed and the lease road up to the driveway will be graded and seeded. The location will be graded level, rocks removed and seeded so that the yard can be brought back to a condition that will allow for it to be mowed with a lawnmower. This work will begin within a week and at when the work completed final restoration can be passed.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| 1479287150
 +
| 2015-01-13
 +
|
 +
| I was on location to check the final restoration for this well and complaint #4668. The location has been seeded and straw spread, but restoration not passed. The location needs to be graded flat, the power poles removed and the brine vault removed from the ground. The G & O office has been contacted and informed of these findings. The final restoration requirements need to be completed before it can be passed.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -1479616099
 +
| 2015-05-21
 +
|
 +
| I was on location to follow up to complaint #4668. The final restoration for this well has not been completed at this time. The location has been graded. The concrete pad for the separator and the power poles for the pumpjack have been removed. A dozer and tractor with a rake is on location for the final dirt work, the location is going to be seeded and when vegetation has been established final restoration will be passed.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| 178961674
 +
| 2015-01-23
 +
|
 +
| I was on location to follow up to complaint #4668. The concrete pad located inside the tank battery has been identified as the base for the vertical separator in the well. I have contacted G&O Resources and informed them that they must remove the power poles present at the location, the separator concrete pad and grade and seed the location. The contractor has my contact and will inform me when they will be on location to perform the work.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| 349078641
 +
| 2014-10-20
 +
|
 +
| On 10/20/2014, I witnessed Hagen Well Service plug the well for G & O Resources.  PetroSet was the cementing contractor.  Hagen ran 2.375
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -356197404
 +
| 2014-10-23
 +
|
 +
| I was on location to check the status of restoration of this location following the plugging of the this well. The well has been plugged and the casing cut down below grade and covered with soil. The location is muddy and will be graded flat and seeded. The tank battery and steam tubs from the tubing are still on location and will need removed from location and cleaned.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -498598961
 +
| 2015-04-30
 +
|
 +
| I was on location to follow up to complaint #4668. The final restoration for this well has not been completed at this time. The location has been seeded but not graded. The concrete pad for the separator is still present and the power poles for the pumpjack are still on location and have not been removed. The landowner was contacted by Lakeside regarding the restoration of the location. The landowner and Lakeside would like to set up a meeting at the location to discuss the final restoration on the well. I have left a message for Ron at Lakeside regarding the meeting. The 6 month period for final restoration has passed at this time.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
| 1398095295
+
| -571113752
| 2014-04-21
+
| 2014-12-30
|
+
|  
| I was on location to perform an inspection of this well regarding complaint #4668. During my inspection I found a graveled lease road that is used as a residential driveway. The tank battery consists of two empty 210 bbls production tanks and a vertical separator, all within an earthen dike. The tank battery and well have an I.D. sign present but it is not legible. The pump jack well does not have the required shroud around the drive belts and electric motor. There is a house gas connection on the well but it is not currently functioning. I have contacted the operator and informed them of the issues. This well is currently on the G&O Resources plugging list when plugging funds are available. The only production shown for this well since 2009 is 31 barrels of oil produced in 2010. This well shall be plugged with 180 days as required by ORC 1509.12B.
+
| I was on location to check the status of final restoration. The location has been seeded and had straw layer down. The location was not graded, the flow lines are still present, the brine vault is still present in the former tank battery and the power line poles to the pumpjack have not been removed. I have called the G&O office and left a message with the secretary and Bill Lavin informing the company that these issues need addressed before final restoration will be passed.
|
+
|  
| NONE
+
|  
|
+
|  
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Ohio Department of Natural Resources RBDMS
 +
| publisher = [http://oilandgas.ohiodnr.gov/]
 +
| date = 2015-06-19
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
 +
| accessdate = 2015-06-20 }}</ref>
 +
== References ==
 +
{{reflist}}
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Wells]]
 
[[Category:Wells]]

Revision as of 22:03, 15 July 2015

Well Details

Well ID: 34-151-21261
Loading map...
County: Stark
Municipality:
Operator Name: G & O RESOURCES LTD
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1967-07-28
Unconventional: No
Configuration: Vertical
Well Status: Plugged and Abandoned
Violations: 0
Latitude: 40.79300557
Longitude: -81.30202356

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1984-0 522.0 328.0
1987-0 769.0 191.0
1988-0 517.0 164.0
1989-0 290.0 212.0
1990-0 694.0 191.0
1991-0 627.0 202.0
1992-0 772.0 200.0
1993-0 0.0 104.0
1994-0 294.0 195.0
1995-0 247.0 180.0
1996-0 608.0 287.0
1997-0 352.0 90.0
1998-0 565.0 212.0
1999-0 493.0 151.0
2000-0 451.0 144.0
2001-0 345.0 183.0
2002-0 247.0 88.0
2003-0 321.0 142.0
2004-0 47.0 135.0
2005-0 23.0 146.0
2006-0 0.0 47.0
2007-0 0.0 161.0
2008-0 0.0 86.0
2009-0 0.0 0.0
2010-0 0.0 31.0
2011-0 0.0 0.0
2012-0 0.0 0.0
2013-0 0.0 0.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1398095295 2014-04-21 I was on location to perform an inspection of this well regarding complaint #4668. During my inspection I found a graveled lease road that is used as a residential driveway. The tank battery consists of two empty 210 bbls production tanks and a vertical separator, all within an earthen dike. The tank battery and well have an I.D. sign present but it is not legible. The pump jack well does not have the required shroud around the drive belts and electric motor. There is a house gas connection on the well but it is not currently functioning. I have contacted the operator and informed them of the issues. This well is currently on the G&O Resources plugging list when plugging funds are available. The only production shown for this well since 2009 is 31 barrels of oil produced in 2010. This well shall be plugged with 180 days as required by ORC 1509.12B.
1413304733 2014-10-14 I was on location to check the status of Steve Hagen Well Service plugging this well. The rig is on location and the area is being lined with plastic. The plugging of the well and the plug schedule was discussed and it was decided plugs would be set through tubing due to concerns with 4.5 diameter production casing integrity. They will pull rods today and prepare to cement tomorrow 10-15-2014.
1413893168 2014-10-16 On 10/16/2014, I was on location to witness Hagen Well Service plug the well for G & O Resources. PetroSet Cementing Services was cementing contractor. First, Hagen ran 2.375
1427900506 2015-04-01 I was on location to follow up to complaint #4668. No additional restoration work has been conducted on this well since the last inspection on 1/23/2015. The 6 month timeframe for final restoration will be on 4/20/2015. Currently the power poles, concrete base for the separator, lease road and ruts in the straw covered ground are present. These issue must be addressed before restoration will be passed.
1430919431 2015-05-05 I was on the location with the landowner and Ron of Lakeside to agree upon the final restoration for this well. The power poles will be pulled from the ground and left on location for a contractor to remove. The concrete pad for the separator will be removed and the lease road up to the driveway will be graded and seeded. The location will be graded level, rocks removed and seeded so that the yard can be brought back to a condition that will allow for it to be mowed with a lawnmower. This work will begin within a week and at when the work completed final restoration can be passed.
1479287150 2015-01-13 I was on location to check the final restoration for this well and complaint #4668. The location has been seeded and straw spread, but restoration not passed. The location needs to be graded flat, the power poles removed and the brine vault removed from the ground. The G & O office has been contacted and informed of these findings. The final restoration requirements need to be completed before it can be passed.
-1479616099 2015-05-21 I was on location to follow up to complaint #4668. The final restoration for this well has not been completed at this time. The location has been graded. The concrete pad for the separator and the power poles for the pumpjack have been removed. A dozer and tractor with a rake is on location for the final dirt work, the location is going to be seeded and when vegetation has been established final restoration will be passed.
178961674 2015-01-23 I was on location to follow up to complaint #4668. The concrete pad located inside the tank battery has been identified as the base for the vertical separator in the well. I have contacted G&O Resources and informed them that they must remove the power poles present at the location, the separator concrete pad and grade and seed the location. The contractor has my contact and will inform me when they will be on location to perform the work.
349078641 2014-10-20 On 10/20/2014, I witnessed Hagen Well Service plug the well for G & O Resources. PetroSet was the cementing contractor. Hagen ran 2.375
-356197404 2014-10-23 I was on location to check the status of restoration of this location following the plugging of the this well. The well has been plugged and the casing cut down below grade and covered with soil. The location is muddy and will be graded flat and seeded. The tank battery and steam tubs from the tubing are still on location and will need removed from location and cleaned.
-498598961 2015-04-30 I was on location to follow up to complaint #4668. The final restoration for this well has not been completed at this time. The location has been seeded but not graded. The concrete pad for the separator is still present and the power poles for the pumpjack are still on location and have not been removed. The landowner was contacted by Lakeside regarding the restoration of the location. The landowner and Lakeside would like to set up a meeting at the location to discuss the final restoration on the well. I have left a message for Ron at Lakeside regarding the meeting. The 6 month period for final restoration has passed at this time.
-571113752 2014-12-30 I was on location to check the status of final restoration. The location has been seeded and had straw layer down. The location was not graded, the flow lines are still present, the brine vault is still present in the former tank battery and the power line poles to the pumpjack have not been removed. I have called the G&O office and left a message with the secretary and Bill Lavin informing the company that these issues need addressed before final restoration will be passed.