{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-25393 | | Well ID: 37-059-25393 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 39.986417, -80.280428 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: [[Morris Township, | + | | State: Pennsylvania |
+ | |- | ||
+ | | County: [[Greene_County,_Pennsylvania|Greene]] | ||
+ | |- | ||
+ | | Municipality: [[Morris Township,_Greene_County,_Pennsylvania|Morris Township]] | ||
|- | |- | ||
| Operator Name: [[CNX GAS CO LLC]] | | Operator Name: [[CNX GAS CO LLC]] | ||
|- | |- | ||
− | | Well Pad ID: [[ | + | | Well Pad ID: [[148000]] |
|- | |- | ||
| Farm/Lease Name: CONRHEIN NV26CCV | | Farm/Lease Name: CONRHEIN NV26CCV | ||
|- | |- | ||
− | | | + | | License Status: Active |
|- | |- | ||
− | | | + | | Spud Date: 05/12/2010 |
|- | |- | ||
− | | | + | | Permit Date: 1/6/2010 |
|- | |- | ||
− | | Unconventional: | + | | Unconventional Well: Y |
|- | |- | ||
− | | Horizontal | + | | Configuration: Horizontal Well |
|- | |- | ||
− | + | | Latitude: 39.986417 | |
− | |||
− | |||
− | |||
− | | Latitude: 39. | ||
− | |||
− | |||
|- | |- | ||
+ | | Longitude: -80.280428 | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
+ | !scope="col" | Water Production Days | ||
|- | |- | ||
− | | 2010 | + | | 2010 |
− | | style="text-align:right;" | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 73,234.02 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 37 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2011 | ||
+ | | [[CNX GAS CO LLC]] | ||
+ | | style="text-align: right;" | 564,083.57 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2012 |
− | | style="text-align:right;" | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 410,417.57 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 366 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2013 | ||
+ | | [[CNX GAS CO LLC]] | ||
+ | | style="text-align: right;" | 182,884.58 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2014 |
− | | style="text-align:right;" | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 282,275.70 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2015 | ||
+ | | [[CNX GAS CO LLC]] | ||
+ | | style="text-align: right;" | 225,204.86 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2016 |
− | | style="text-align:right;" | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 60,526.83 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 126 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2017 | ||
+ | | [[CNX GAS CO LLC]] | ||
+ | | style="text-align: right;" | 27,481.06 | ||
+ | | style="text-align: right;" | 64 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2018 |
− | | style="text-align:right;" | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 170,410.08 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 359 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2019 | ||
+ | | [[CNX GAS CO LLC]] | ||
+ | | style="text-align: right;" | 39,250.70 | ||
+ | | style="text-align: right;" | 90 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |} |
− | | | + | For data sources see<ref>{{cite web |
− | | | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | + | | accessdate = 2019-05-21 }}</ref> | |
+ | == Waste Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Period | ||
+ | !scope="col" | Waste Type | ||
+ | !scope="col" | Quantity | ||
+ | !scope="col" | Disposal Method | ||
+ | !scope="col" | Waste Facility ID | ||
|- | |- | ||
+ | | 15AUGU | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 68.33 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 15DECU |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 36.66 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | |||
− | |||
|- | |- | ||
+ | | 15JULU | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 146.66 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 15NOVU |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 106.66 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | |||
− | |||
|- | |- | ||
+ | | 15OCTU | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 70.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 15SEPU |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 73.33 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | |||
− | |||
|- | |- | ||
+ | | 16APRU | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 16AUGU |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 37.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | |||
− | |||
|- | |- | ||
+ | | 16DECU | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 37.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 16FEBU |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 73.32 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | |||
− | |||
|- | |- | ||
+ | | 16JANU | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 16JULU |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 36.70 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | |||
− | |||
|- | |- | ||
+ | | 16JUNU | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 15.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 16MARU |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 73.34 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | |||
− | |||
|- | |- | ||
+ | | 16MAYU | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.66 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 16OCTU |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 4.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | |||
− | |||
|- | |- | ||
− | | | + | | 16SEPU |
− | + | | Produced Fluid (in Barrels) RWC 802 | |
− | + | | style="text-align: right;" | 37.00 Bbl | |
− | + | | REUSE OTHER THAN ROAD SPREADING | |
− | + | | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2010-2 | | 2010-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 893.64 | + | | style="text-align: right;" | 893.64 Bbl |
− | |||
| PUBLIC SEWAGE TREATMENT PLANT | | PUBLIC SEWAGE TREATMENT PLANT | ||
| PA0026913 | | PA0026913 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-1 | | 2011-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 35. | + | | style="text-align: right;" | 35.00 Bbl |
− | |||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0026824 | | PA0026824 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-1 | | 2011-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 2. | + | | style="text-align: right;" | 2,491.00 Bbl |
− | |||
| PUBLIC SEWAGE TREATMENT PLANT | | PUBLIC SEWAGE TREATMENT PLANT | ||
| PA0026913 | | PA0026913 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-1 | | 2011-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 878. | + | | style="text-align: right;" | 878.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-2 | | 2011-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 973.46 | + | | style="text-align: right;" | 973.46 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2012-1 | | 2012-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 770.21 | + | | style="text-align: right;" | 770.21 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 2012-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 52.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-013-20609 | ||
|- | |- | ||
| 2012-2 | | 2012-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 37. | + | | style="text-align: right;" | 37.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-031-27177 | | 34-031-27177 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2012-2 | | 2012-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 90.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-121-23995 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2012-2 | | 2012-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 819. | + | | style="text-align: right;" | 819.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-1 | | 2013-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 829.19 | + | | style="text-align: right;" | 829.19 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 2013-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 23.88 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-013-20609 | ||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 16.98 | + | | style="text-align: right;" | 16.98 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-031-27177 | | 34-031-27177 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2013-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 9.31 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-059-24202 | ||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 66.48 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-105-23619 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 0.88 | + | | style="text-align: right;" | 0.88 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-119-28776 | | 34-119-28776 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 830.32 | + | | style="text-align: right;" | 830.32 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 2014-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 8.34 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 2D0859721 | ||
|- | |- | ||
− | | | + | | 2014-1 |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 38.38 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-013-20609 |
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2014-1 |
− | | | + | | Produced Fluid (in Barrels) |
− | + | | style="text-align: right;" | 31.71 Bbl | |
− | | style="text-align:right;" | | ||
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-059-24202 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 8.34 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-119-28776 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 10.01 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-121-23995 |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 568.11 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 70.09 | + | | style="text-align: right;" | 70.09 Bbl |
− | |||
| STORAGE PENDING DISPOSAL OR REUSE | | STORAGE PENDING DISPOSAL OR REUSE | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 836.67 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2015-07 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 146.66 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2015-08 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 68.33 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2015-09 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2015-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 613.25 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2015-10 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 70.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2015-11 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 106.66 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2015-12 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 36.66 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2016-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2016-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.32 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2016-03 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 73.34 Bbl |
− | | Bbl | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
− | | | + | |- |
− | | | + | | 2016-04 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 73.33 Bbl |
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2016-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.66 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2016-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 15.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2016-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.70 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2016-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 37.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
+ | | 2016-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 37.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2016-10 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 4.00 Bbl |
− | | Bbl | + | | REUSE OTHER THAN ROAD SPREADING |
+ | | | ||
+ | |- | ||
+ | | 2016-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 37.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2017-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-10 | ||
+ | |- | ||
+ | | 2017-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 16.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-10 | ||
+ | |- | ||
+ | | 2017-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 30.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2017-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-21 | ||
+ | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-17 | ||
+ | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-21 | ||
+ | |- | ||
+ | | 2017-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-10 | ||
+ | |- | ||
+ | | 2017-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-16 | ||
+ | |- | ||
+ | | 2017-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-10 | ||
+ | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-10 | ||
+ | |- | ||
+ | | 2017-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-17 | ||
+ | |- | ||
+ | | 2017-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 31.33 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-10 | ||
+ | |- | ||
+ | | 2017-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 20.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2017-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2017-11 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 53.33 Bbl |
− | | Bbl | + | | REUSE (AT WELL PAD) |
+ | | | ||
+ | |- | ||
+ | | 2017-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-21 | ||
+ | |- | ||
+ | | 2017-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-17 | ||
+ | |- | ||
+ | | 2017-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2017-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-21 | ||
+ | |- | ||
+ | | 2018-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 18.33 Bbl | ||
+ | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
+ | | PA0095273 | ||
+ | |- | ||
+ | | 2018-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 25.33 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-119-28803 |
− | | | + | |- |
− | | | + | | 2018-01 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
+ | | 2018-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
|- | |- | ||
− | | | + | | 2018-02 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 114.67 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-119-28803 |
− | | | + | |- |
− | | | + | | 2018-02 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 116.84 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 101.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
+ | | 2018-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
|- | |- | ||
− | | | + | | 2018-05 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 73.33 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2018-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-21 | ||
+ | |- | ||
+ | | 2018-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 113.33 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-17 | ||
+ | |- | ||
+ | | 2018-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 209.33 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 73.33 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-21 | ||
+ | |- | ||
+ | | 2018-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 40.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-17 | ||
+ | |- | ||
+ | | 2018-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 90.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2018-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 40.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-17 | ||
+ | |- | ||
+ | | 2018-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 49.67 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
+ | |- | ||
+ | | 2019-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 16.67 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
+ | |- | ||
+ | | 2019-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 45.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-21 | ||
+ | |- | ||
+ | | 2019-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 31.33 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-157-25511 | ||
+ | |- | ||
+ | | 2019-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2019-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 55.00 Bbl | ||
+ | | SURFACE IMPOUNDMENT | ||
+ | | 95-7-37312-19 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
− | + | !scope="col" | Inspection Comments | |
− | !scope="col" | | ||
|- | |- | ||
| 2163856 | | 2163856 | ||
− | | | + | | Primary Facility |
+ | | 04/18/2013 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| ROUTINE INSPECTION. WELL COMPLIANT AT TIME OF INSPECTION. | | ROUTINE INSPECTION. WELL COMPLIANT AT TIME OF INSPECTION. | ||
− | | | + | |- |
− | | | + | | 2309432 |
− | | | + | | Primary Facility |
+ | | 07/30/2014 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | On 7/30/2014, I performed an inspection of CNX's NV26 well pad site. The site is located in Morris Twp., Greene County. The inspection was performed as a routine inspection related to termination of the earth disturbance permit request by the operator. | ||
+ | |- | ||
+ | | 2618100 | ||
+ | | Primary Facility | ||
+ | | 2017-07-20 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | On Thursday, July 20, 2017, I conducted a routine-complete inspection at the NV26 Well Site located in Morris Township, Greene County. | ||
+ | |||
+ | The access road and well pad were in decent condition and the site has been stabilized with vegetation. | ||
+ | |||
+ | The secondary containment around the production tank appeared to be in good condition and functioning as intended. The gas wells appeared to be in good working order and each was labelled as required. | ||
+ | |||
+ | The ESCGP for the site construction was terminated in August 2014. Although the operator is not required to keep permit drawings on-site, the operator should consider keeping an as-built drawing relative to the site restoration plan and including any required PCSM controls. | ||
+ | |||
+ | A Frac tank was observed on-site placed within a hay bail and poly liner containment structure. Several holes were observed in the poly liner of the containment. Although the use of the tank is not known, the tanks should not be used until the breaches in containment have been repaired or the poly l | ||
+ | |- | ||
+ | | 2719449 | ||
+ | | Primary Facility | ||
+ | | 2018-04-03 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | On Tuesday, April 3, 2018, I conducted a routine-complete inspection at the NV26 Well Site located in Morris Township, Greene County. | ||
+ | |||
+ | The NV26CCV gas well and the associated infrastructure appeared to be in good condition and functioning properly. The well was tagged. | ||
+ | |||
+ | No violations were identified during the inspection. | ||
+ | |- | ||
+ | |} | ||
+ | <!--==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
+ | |- | ||
+ | |}--> | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 11/19/2010 | ||
+ | | 11/19/2010 | ||
+ | | style="text-align: right;" | 7870.0 | ||
+ | | style="text-align: right;" | 4450381.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="13"| 1 | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| | ||
+ | | rowspan="1"| Carrier | ||
+ | | Water | ||
+ | | NA | ||
+ | | style="text-align: right;" | 100.0 | ||
+ | | style="text-align: right;" | 96.3322 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Hydrochloric Acid | ||
+ | | rowspan="1"| CWS | ||
+ | | rowspan="1"| Acid | ||
+ | | Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15.0 | ||
+ | | style="text-align: right;" | 0.11235 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| DWP-938 | ||
+ | | rowspan="1"| CWS | ||
+ | | rowspan="1"| Surfactant | ||
+ | | Soap | ||
+ | | NA | ||
+ | | style="text-align: right;" | None | ||
+ | | style="text-align: right;" | 0.07285 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| DWP-612 | ||
+ | | rowspan="1"| CWS | ||
+ | | rowspan="1"| Friction Reduction | ||
+ | | Long Chain Polyacrylamide | ||
+ | | NA | ||
+ | | style="text-align: right;" | None | ||
+ | | style="text-align: right;" | 0.18558 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| DWP-944 | ||
+ | | rowspan="1"| CWS | ||
+ | | rowspan="1"| Biocide | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 20.0 | ||
+ | | style="text-align: right;" | 0.00908 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="6"| | ||
+ | | rowspan="6"| | ||
+ | | rowspan="6"| | ||
+ | | Organic Phosphonate | ||
+ | | NA | ||
+ | | style="text-align: right;" | 30.0 | ||
+ | | style="text-align: right;" | 0.00442 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Oxyalkylated Polyamine | ||
+ | | NA | ||
+ | | style="text-align: right;" | 5.0 | ||
+ | | style="text-align: right;" | 0.00074 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Ammonium Chloride | ||
+ | | 12125-02-9 | ||
+ | | style="text-align: right;" | 10.0 | ||
+ | | style="text-align: right;" | 0.00147 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Polyethylene Glycol Mixture | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60.0 | ||
+ | | style="text-align: right;" | 0.00908 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Amine Salt | ||
+ | | NA | ||
+ | | style="text-align: right;" | 5.0 | ||
+ | | style="text-align: right;" | 0.00074 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Phosphoric Acid Ammonium Salt | ||
+ | | NA | ||
+ | | style="text-align: right;" | 5.0 | ||
+ | | style="text-align: right;" | 0.00074 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand | ||
+ | | rowspan="1"| | ||
+ | | rowspan="1"| Proppant | ||
+ | | Sand | ||
+ | | NA | ||
+ | | style="text-align: right;" | 100.0 | ||
+ | | style="text-align: right;" | 3.27323 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| DAP-901 | ||
+ | | rowspan="1"| CWS | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 30.0 | ||
+ | | style="text-align: right;" | 0.00442 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | accessdate = 2019-06-19 }}</ref> |
− | | accessdate = | + | ==References== |
− | == References == | + | <references/> |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-059-25393 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.986417,"lon":-80.280428,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Morris Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 148000 | |
Farm/Lease Name: CONRHEIN NV26CCV | |
License Status: Active | |
Spud Date: 05/12/2010 | |
Permit Date: 1/6/2010 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.986417 | |
Longitude: -80.280428 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CNX GAS CO LLC | 73,234.02 | 37 | 0.00 | 0 | 0.00 | 0 |
2011 | CNX GAS CO LLC | 564,083.57 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | CNX GAS CO LLC | 410,417.57 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | CNX GAS CO LLC | 182,884.58 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CNX GAS CO LLC | 282,275.70 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | CNX GAS CO LLC | 225,204.86 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CNX GAS CO LLC | 60,526.83 | 126 | 0.00 | 0 | 0.00 | 0 |
2017 | CNX GAS CO LLC | 27,481.06 | 64 | 0.00 | 0 | 0.00 | 0 |
2018 | CNX GAS CO LLC | 170,410.08 | 359 | 0.00 | 0 | 0.00 | 0 |
2019 | CNX GAS CO LLC | 39,250.70 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
15AUGU | Produced Fluid (in Barrels) | 68.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
15DECU | Produced Fluid (in Barrels) | 36.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
15JULU | Produced Fluid (in Barrels) | 146.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
15NOVU | Produced Fluid (in Barrels) | 106.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
15OCTU | Produced Fluid (in Barrels) | 70.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
15SEPU | Produced Fluid (in Barrels) | 73.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16APRU | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16AUGU | Produced Fluid (in Barrels) RWC 802 | 37.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16DECU | Produced Fluid (in Barrels) RWC 802 | 37.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16FEBU | Produced Fluid (in Barrels) RWC 802 | 73.32 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16JANU | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16JULU | Produced Fluid (in Barrels) RWC 802 | 36.70 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16JUNU | Produced Fluid (in Barrels) RWC 802 | 15.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16MARU | Produced Fluid (in Barrels) RWC 802 | 73.34 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16MAYU | Produced Fluid (in Barrels) RWC 802 | 36.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16OCTU | Produced Fluid (in Barrels) RWC 802 | 4.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
16SEPU | Produced Fluid (in Barrels) RWC 802 | 37.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2010-2 | Produced Fluid (in Barrels) | 893.64 Bbl | PUBLIC SEWAGE TREATMENT PLANT | PA0026913 |
2011-1 | Produced Fluid (in Barrels) | 35.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0026824 |
2011-1 | Produced Fluid (in Barrels) | 2,491.00 Bbl | PUBLIC SEWAGE TREATMENT PLANT | PA0026913 |
2011-1 | Produced Fluid (in Barrels) | 878.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-2 | Produced Fluid (in Barrels) | 973.46 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-1 | Produced Fluid (in Barrels) | 770.21 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-2 | Produced Fluid (in Barrels) | 52.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2012-2 | Produced Fluid (in Barrels) | 37.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2012-2 | Produced Fluid (in Barrels) | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2012-2 | Produced Fluid (in Barrels) | 819.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-1 | Produced Fluid (in Barrels) | 829.19 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Produced Fluid (in Barrels) | 23.88 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2013-2 | Produced Fluid (in Barrels) | 16.98 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2013-2 | Produced Fluid (in Barrels) | 9.31 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2013-2 | Produced Fluid (in Barrels) | 66.48 Bbl | INJECTION DISPOSAL WELL | 34-105-23619 |
2013-2 | Produced Fluid (in Barrels) | 0.88 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2013-2 | Produced Fluid (in Barrels) | 830.32 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Produced Fluid (in Barrels) | 8.34 Bbl | INJECTION DISPOSAL WELL | 2D0859721 |
2014-1 | Produced Fluid (in Barrels) | 38.38 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2014-1 | Produced Fluid (in Barrels) | 31.71 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2014-1 | Produced Fluid (in Barrels) | 8.34 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2014-1 | Produced Fluid (in Barrels) | 10.01 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014-1 | Produced Fluid (in Barrels) | 568.11 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Produced Fluid (in Barrels) | 70.09 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2014-2 | Produced Fluid (in Barrels) | 836.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-07 | Produced Fluid (in Barrels) | 146.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-08 | Produced Fluid (in Barrels) | 68.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-09 | Produced Fluid (in Barrels) | 73.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Produced Fluid (in Barrels) | 613.25 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-10 | Produced Fluid (in Barrels) | 70.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-11 | Produced Fluid (in Barrels) | 106.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-12 | Produced Fluid (in Barrels) | 36.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-01 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-02 | Produced Fluid (in Barrels) RWC 802 | 73.32 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-03 | Produced Fluid (in Barrels) RWC 802 | 73.34 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-04 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-05 | Produced Fluid (in Barrels) RWC 802 | 36.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-06 | Produced Fluid (in Barrels) RWC 802 | 15.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-07 | Produced Fluid (in Barrels) RWC 802 | 36.70 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-08 | Produced Fluid (in Barrels) RWC 802 | 37.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-09 | Produced Fluid (in Barrels) RWC 802 | 37.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-10 | Produced Fluid (in Barrels) RWC 802 | 4.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-12 | Produced Fluid (in Barrels) RWC 802 | 37.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 16.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-16 |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 31.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 20.00 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 53.33 Bbl | REUSE (AT WELL PAD) | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 25.33 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 114.67 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 116.84 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 101.67 Bbl | REUSE (AT WELL PAD) | |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | REUSE (AT WELL PAD) | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 113.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 209.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 90.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 49.67 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 16.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 45.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 31.33 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2163856 | Primary Facility | 04/18/2013 | Routine/Complete Inspection | No Violations Noted | ROUTINE INSPECTION. WELL COMPLIANT AT TIME OF INSPECTION. |
2309432 | Primary Facility | 07/30/2014 | Routine/Complete Inspection | No Violations Noted | On 7/30/2014, I performed an inspection of CNX's NV26 well pad site. The site is located in Morris Twp., Greene County. The inspection was performed as a routine inspection related to termination of the earth disturbance permit request by the operator. |
2618100 | Primary Facility | 2017-07-20 | Routine/Complete Inspection | No Violations Noted | On Thursday, July 20, 2017, I conducted a routine-complete inspection at the NV26 Well Site located in Morris Township, Greene County.
The access road and well pad were in decent condition and the site has been stabilized with vegetation. The secondary containment around the production tank appeared to be in good condition and functioning as intended. The gas wells appeared to be in good working order and each was labelled as required. The ESCGP for the site construction was terminated in August 2014. Although the operator is not required to keep permit drawings on-site, the operator should consider keeping an as-built drawing relative to the site restoration plan and including any required PCSM controls. A Frac tank was observed on-site placed within a hay bail and poly liner containment structure. Several holes were observed in the poly liner of the containment. Although the use of the tank is not known, the tanks should not be used until the breaches in containment have been repaired or the poly l |
2719449 | Primary Facility | 2018-04-03 | Routine/Complete Inspection | No Violations Noted | On Tuesday, April 3, 2018, I conducted a routine-complete inspection at the NV26 Well Site located in Morris Township, Greene County.
The NV26CCV gas well and the associated infrastructure appeared to be in good condition and functioning properly. The well was tagged. No violations were identified during the inspection. |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 11/19/2010 | 11/19/2010 | 7870.0 | 4450381.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Carrier | Water | NA | 100.0 | 96.3322 | ||
Hydrochloric Acid | CWS | Acid | Hydrochloric Acid | 7647-01-0 | 15.0 | 0.11235 | ||
DWP-938 | CWS | Surfactant | Soap | NA | None | 0.07285 | ||
DWP-612 | CWS | Friction Reduction | Long Chain Polyacrylamide | NA | None | 0.18558 | ||
DWP-944 | CWS | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.0 | 0.00908 | ||
Organic Phosphonate | NA | 30.0 | 0.00442 | |||||
Oxyalkylated Polyamine | NA | 5.0 | 0.00074 | |||||
Ammonium Chloride | 12125-02-9 | 10.0 | 0.00147 | |||||
Polyethylene Glycol Mixture | 25322-68-3 | 60.0 | 0.00908 | |||||
Amine Salt | NA | 5.0 | 0.00074 | |||||
Phosphoric Acid Ammonium Salt | NA | 5.0 | 0.00074 | |||||
Sand | Proppant | Sand | NA | 100.0 | 3.27323 | |||
DAP-901 | CWS | Scale Inhibitor | Methanol | 67-56-1 | 30.0 | 0.00442 |
For data sources see[7]