X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-125-27180"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-125-27180
 
| Well ID: 37-125-27180
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.164788, -79.944638 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.164789, -79.944639 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Washington County, Pennsylvania|Washington]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Carroll Township, Washington County, Pennsylvania|Carroll Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[EQT PRODUCTION CO]]
+
| County: [[Washington_County,_Pennsylvania|Washington]]
 
|-
 
|-
| Well Pad ID: [[145213|145213]]
+
| Municipality: [[Carroll Township,_Washington_County,_Pennsylvania|Carroll Township]]
 
|-
 
|-
| Farm/Lease Name: R SMITH 592301
+
| Operator Name: [[EQT PROD CO]]
 
|-
 
|-
| First Permit Date: 2013-11-26
+
| Well Pad ID: [[145213]]
 
|-
 
|-
| Last Permit Date: 2014-04-01
+
| Farm/Lease Name: R SMITH 592301
 
|-
 
|-
| Spud Date: 2013-12-06
+
| License Status: Active
 
|-
 
|-
| Unconventional: Yes
+
| Spud Date: 12/06/2013
 
|-
 
|-
| Horizontal: Yes
+
| Permit Date: 11/26/2013
 
|-
 
|-
| Well Status: ACTIVE
+
| Unconventional Well: Y
 
|-
 
|-
| Violations: 0
+
| Configuration: Horizontal Well
 
|-
 
|-
| Latitude: 40.164788
+
| Latitude: 40.164789
|-
 
| Longitude: -79.944638
 
 
|-
 
|-
 +
| Longitude: -79.944639
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
|-
+
!scope="col" | Water Production Days
| 2013-2
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2014-1
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
 
|-
 
|-
| 2014-2
+
| 2013
| style="text-align:right;" | 404033.0
+
| [[EQT PROD CO]]
| style="text-align:right;" | 70.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2014
 +
| [[EQT PROD CO]]
 +
| style="text-align: right;" | 404,033.00
 +
| style="text-align: right;" | 70
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2015-02
+
| 2015
| style="text-align:right;" | 218073.0
+
| [[EQT PROD CO]]
| style="text-align:right;" | 28.0
+
| style="text-align: right;" | 2,406,829.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 358
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[EQT PROD CO]]
 +
| style="text-align: right;" | 2,382,650.00
 +
| style="text-align: right;" | 347
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2015-01
+
| 2017
| style="text-align:right;" | 186839.0
+
| [[EQT PROD CO]]
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 1,243,257.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 353
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2018
 +
| [[EQT PROD CO]]
 +
| style="text-align: right;" | 420,585.00
 +
| style="text-align: right;" | 283
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2015-03
+
| 2019
| style="text-align:right;" | 219137.0
+
| [[EQT PROD CO]]
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 58,267.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 24
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 576.66
+
| style="text-align: right;" | 457.50 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
| 100419
+
| 100277
| ADVANCED DISPOSAL SERVICE CHESTNUT VALLEY LANDFILL
 
| MCCLELLANDTOWN
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 457.5
+
| style="text-align: right;" | 576.66 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
| 100277
+
| 100419
| WESTMORELAND WASTE LLC SANITARY LANDFILL
 
| BELLE VERNON
 
| PA
 
 
|-
 
|-
 +
| 2014-2
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 7,876.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| FLOWBACK FRACTURING SAND
+
| Fracturing Fluid Waste (in Tons)
| style="text-align:right;" | 47.0
+
| style="text-align: right;" | 47.00 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 101571
 
| 101571
| MOSTOLLER LANDFILL
 
| SOMERSET
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| FLOWBACK FRACTURING SAND
+
| Fracturing Fluid Waste (in Tons)
| style="text-align:right;" | 4.0
+
| style="text-align: right;" | 4.00 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| SWF 1032-WV0109
 
| SWF 1032-WV0109
| WASTE MANAGEMENT, INC -  MEADOWFILL LANDFILL
 
| BRIDGEMENT
 
| WV
 
 
|-
 
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 110.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-031-27177
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 7.0
+
| style="text-align: right;" | 220.00 Bbl
| Bbl
+
| INJECTION DISPOSAL WELL
 +
| 34-157-25511
 +
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 9,765.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 80.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-059-24202
 +
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 310.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-157-25511
 +
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,430.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW005
 +
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 12,321.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2015-2
 +
| Drilling Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 220.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2015-2
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 1,320.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 550.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW005
 +
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 6,270.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 899.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW005
 +
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 9,035.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016-2
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 410.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 49.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW005
 +
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 817.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 5,149.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2017-01
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 64.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 390.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 456.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 130.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 260.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 195.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 120.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 110.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 370.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 110.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 110.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 110.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 61.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 12.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 3.39 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2014-2
+
| 2017-11
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 110.0
+
| style="text-align: right;" | 137.31 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 51.43 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-031-27177
 
| 34-031-27177
| ADAMS #1 (SWIW #10)
 
| COSHOCTON
 
| OH
 
 
|-
 
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 9.17 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
|
 +
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 137.56 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 4.39 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 117.11 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1.82 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 18.48 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1.38 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-03
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 10.45 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
|
 
|-
 
|-
| 2014-2
+
| 2018-03
| PRODUCED FLUID
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| style="text-align:right;" | 220.0
+
| style="text-align: right;" | 37.27 Bbl
| Bbl
+
| RESIDUAL WASTE PROCESSING FACILITY
| INJECTION DISPOSAL WELL
+
| WMGR123SW005
| 34-157-25511
+
|-
| MOZENA  #1 (SWIW #13)
+
| 2018-03
| NEWCOMERSTOWN
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| OH
+
| style="text-align: right;" | 2.27 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 19.83 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 2.27 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2018-03
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 9.0
+
| style="text-align: right;" | 8.69 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-04
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 5.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-04
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 2.50 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 0.36 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
|}
+
| 2018-05
For data sources see<ref>{{cite web
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| title = Oil and Gas Historical Waste Report
+
| style="text-align: right;" | 11.82 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| RESIDUAL WASTE PROCESSING FACILITY
| date = 2015-05-26
+
| WMGR123SW005
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
|-
| accessdate = 2015-05-26 }}</ref>
+
| 2018-05
== Inspection Data ==
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
{| class="wikitable sortable" width="95%"
+
| style="text-align: right;" | 13.18 Bbl
!scope="col" | INSPECTION ID
+
| REUSE (AT WELL PAD)
!scope="col" | DATE
+
|  
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| 2231137
+
| 2018-05
| 2013-12-19
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 0.31 Bbl
| Alpha-Hunter drilling for EQT using CLS and flare stack .  Currently drilling the 592303 well.  Cellar and conductor set for this well.  Containment under rig and support equipment.  No violations at time of inspection.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-06
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 14.09 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-06
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 4.09 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 0.30 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 0.89 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2340228
+
| 2018-07
| 2015-01-30
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| No Violations Noted
+
| style="text-align: right;" | 0.91 Bbl
| Violations for todays inspection linked to site inspection 2340109 enforcement 319619
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-07
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 5.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.74 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 10.31 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-08
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 5.45 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2343343
+
| 2018-08
| 2015-02-10
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 4.79 Bbl
| Well in production. Well in compliance with environmental regulations.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-09
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 10.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW009
 +
|-
 +
| 2018-09
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 6.36 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-09
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 5.45 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2018-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 5.31 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2350348
+
| 2018-09
| 2015-02-24
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 5.43 Bbl
| On 02/24/15 at approximately 0900 hours I
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2018-10
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 23.18 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-10
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 5.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 68.06 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 5.50 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2361140
+
| 2018-11
| 2015-04-14
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| No Violations Noted
+
| style="text-align: right;" | 5.00 Bbl
| On April 14th 2015
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 10.35 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-12
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 3.41 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 3.70 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1.77 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2363369
+
| 2019-01
| 2015-02-10
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| No Violations Noted
+
| style="text-align: right;" | 103.63 Bbl
| On 2/10/15 took water samples from well (tap in garage) based on analysis code 946.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 109.96 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-02
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 40.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2019-02
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 5.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2019-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 6.66 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2363387
+
| 2019-02
| 2015-03-12
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 1.78 Bbl
| On 3/12/15 administrative review of lab results with WQS Bryon Miller did not indicate that gas well activities have impacted the water supply at this time.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-03
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 80.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 0.43 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 2.49 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
[[Category:Has Chemical Data]]
+
== Inspection Data ==
==Chemical Data==
+
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | HF Fluid Concentration
+
!scope="col" | Inspection ID
!scope="col" | Ingredient
+
!scope="col" | Inspection Category
!scope="col" | Additive Concentration
+
!scope="col" | Inspection Date
!scope="col" | Trade Name
+
!scope="col" | Inspection Type
!scope="col" | Purpose
+
!scope="col" | Inspection Result
!scope="col" | CAS number
+
!scope="col" | Inspection Comments
!scope="col" | Supplier
 
 
|-
 
|-
| 0.00195978
+
| 2231137
| Ammonium acetate
+
| Primary Facility
| 6.0
+
| 12/19/2013
| FRW-600
+
| Drilling/Alteration
| Friction reducer
+
| No Violations Noted
| 631-61-8
+
| Alpha-Hunter drilling for EQT using CLS and flare stack .  Currently drilling the 592303 well.  Cellar and conductor set for this well.  Containment under rig and support equipment.  No violations at time of inspection.
| FTS International
 
 
|-
 
|-
 +
| 2265725
 +
| Primary Facility
 +
| 04/24/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| Pioneeer 72 drilling for EQT using closed loop system.  Currently waiting on cement from 5 1/2 " production casing.  Pumped 747 Bbls or cement and 50 Bbls of spacer.  for a total of 797 Bbls.  5.5 Bbls returns.    KOP @ 5939.  Landed curve @ 8454.  BOP tested good at nipple up.  Containemnt under rig and support equipment in good conition.  Site is clean.
 
|-
 
|-
| 0.00979891
+
| 2340228
| Hydrotreated light distillate
+
| Primary Facility
| 30.0
+
| 01/30/2015
| FRW-600
+
| Routine/Complete Inspection
| Friction reducer
+
| No Violations Noted
| 64742-47-8
+
| Violations for todays inspection linked to site inspection 2340109 enforcement 319619
| FTS International
 
 
|-
 
|-
 +
| 2343343
 +
| Primary Facility
 +
| 02/10/2015
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Well in production. Well in compliance with environmental regulations.
 
|-
 
|-
| 0.0327095
+
| 2350348
| Hydrochloric Acid
+
| Primary Facility
| 15.0
+
| 02/24/2015
| Hydrochloric Acid (15%)
+
| Routine/Complete Inspection
| Acidizing
+
| No Violations Noted
| 7647-01-0
+
|  
| FTS International
 
 
|-
 
|-
 +
| 2361140
 +
| Primary Facility
 +
| 04/14/2015
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On April 14th 2015, I inspected the Robert Smith Pad in response to an NOT request and made the following observations:
 
|-
 
|-
| 0.00263714
+
| 2363369
| Ethylene glycol
+
| Primary Facility
| 10.0
+
| 02/10/2015
| CS-500-SI
+
| Routine/Partial Inspection
| Scale inhibitor
+
| No Violations Noted
| 107-21-1
+
| On 2/10/15 took water samples from well (tap in garage) based on analysis code 946.
| FTS International
 
 
|-
 
|-
 +
| 2363387
 +
| Primary Facility
 +
| 03/12/2015
 +
| Administrative/File Review
 +
| No Violations Noted
 +
| On 3/12/15 administrative review of lab results with WQS Bryon Miller did not indicate that gas well activities have impacted the water supply at this time.
 
|-
 
|-
| 3.40633e-05
+
| 2402132
| 2-Propanol
+
| Primary Facility
| 10.0
+
| 08/14/2015
| NE-100
+
| Compliance Evaluation
| Non-emulsifier
+
| No Violations Noted
| 67-63-0
+
| On 8/14/15, I inspected the Robert Smith site as a compliance evaluation inspection in response to the remediation report for a spill occurring on 1/31/15 and made the following observations:
| FTS International
 
 
|-
 
|-
 +
| 2544056
 +
| Primary Facility
 +
| 2016-09-14
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 +
| On 9/14/16 I performed an incident response inspection at the Robert Smith Site in response to an operator reported spill (CTS ID:  322335) and made the following observations:
 +
•On 9/6/16 EQT Corey Giles reported a spill of 100 gallons of produced fluids to the well pad.  The spill was forwarded to the WQS on 9/14/16.  This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code § 78.54 for failing to control brine and other fluids resulting in discharge to the ground and failure to prevent pollution to the Waters of the Commonwealth.
 +
•The spill was cleaned up at the time of inspection with the only observed indicator of the spill location being an area of new gravel on the pad near the production units.  No violation.
 +
•Well drilling was ongoing at the time of inspection.
 +
•During general pad inspection it was noted that multiple production tanks had orange streaking running down their sides from the top of the tanks.  The gravel of the pad surface near the containment displayed matching orange stai
 
|-
 
|-
| 1.70316e-05
+
| 2614135
| Dodecylbenzenesulfonic acid
+
| Primary Facility
| 5.0
+
| 2017-05-05
| NE-100
+
| Incident- Response to Accident or Event
| Non-emulsifier
+
| In Compliance with Policy
| 27176-87-0
+
| On 5/5/17 an INCDT inspection of the R. Smith well site was conducted in response to CTS ID:  326715.  The following was observed:
| FTS International
+
 
 +
>> Site was undergoing fracking at time of inspection.
 +
 
 +
>>The spill in question involved roughly 10 gallons of produced water being sprayed from from an overfilled accessory tank on the pad. Affected pad materials were collected and placed in a waste box on pad for disposal.  No violation, site appears to be in compliance with policy.
 +
 
 +
>>Streaking was again noted on the outside of multiple production tanks similar to streaking noted in previous inspections.
 
|-
 
|-
 +
| 2660111
 +
| Primary Facility
 +
| 2017-11-09
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site.  The following was observed:
 +
 +
>>A box tank was found near the impoundment with no containment.  Remediation recommended, no violation.
 +
 +
>>A new top soil stock pile was noted on site.  It was stabilized with straw at the time of inspection.
 +
 +
>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip.  Decomposed CFS should be removed, repaired, or replaced.  No violation.
 +
 +
>>Drilling was ongoing at the site at the time of inspection.
 
|-
 
|-
| 3.40633e-05
+
| 2691652
| 2-Butoxyethanol
+
| Primary Facility
| 10.0
+
| 2018-02-02
| NE-100
+
| Routine/Complete Inspection
| Non-emulsifier
+
| No Violations Noted
| 111-76-2
+
| Well has been fracked and is producing.
| FTS International
 
 
|-
 
|-
 +
| 2705412
 +
| Primary Facility
 +
| 2018-03-13
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad.  The following was observed:
 +
 +
>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities.  No drilling rig was present on site at the time of inspection.
 +
 +
>>Construction of a proposed AST had not begun at the time of inspection.
 +
 +
>>Many water trucks were present on site in association with the attached impoundment.
 
|-
 
|-
| 0.000188923
+
| 2737800
| Surfactant
+
| Primary Facility
| 2.0
+
| 2018-05-16
| HVG-1
+
| Incident- Response to Accident or Event
| Gelling agent
+
| No Violations Noted
| 68439-51-0
+
| On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18.  The following was observed:
| FTS International
+
 
 +
>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first.  Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection.  This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected.
 +
 
 +
>>Site inspection found no residual evidence of the spill.  The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters).
 
|-
 
|-
 +
| 2747127
 +
| Primary Facility
 +
| 2018-06-29
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident.  The following was observed:
 +
 +
>>An unstabilized soil pile near the corner of the pad with a newly improved drain.  Controls below the pile were absent though the vegetation was sufficient.  No violation, remediation recommended.
 +
 +
>>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road.  No controls beyond vegetation were present below the soil pile.  No violation, monitoring recommended.
 +
 +
>>An AST was present on the accessory pad.
 +
 +
>>The pad was active at the time of inspection with drilling preparations ongoing.  A sound wall was present around the pad perimeter.
 
|-
 
|-
| 0.00519538
+
| 2761315
| Petroleum distillate
+
| Primary Facility
| 55.0
+
| 2018-08-02
| HVG-1
+
| Routine/Complete Inspection
| Gelling agent
+
| No Violations Noted
| 64742-47-8
+
| On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad.  WQSS John Carson accompanied.  The following was observed:
| FTS International
+
 
 +
>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization.  The vegetative strip below remains in good condition.  Remediation recommended, no violation.
 +
 
 +
>>Emptying partially filled containment is encouraged to aid in identifying any possible leaks.  No violation.
 +
 
 +
>>No evidence of excessive or unpermitted runoff from the pad was found.
 +
 
 +
>>Box in containment appears to be collecting emergency blowdown.  If so it should be properly marked.  No violation.
 
|-
 
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 
|-
 
|-
| 0.00472307
+
|}-->
| Guar gum
+
<!--==== Penalties Applied ====
| 50.0
+
{| class="wikitable sortable" width="95%"
| HVG-1
+
!scope="col" | Violation ID
| Gelling agent
+
!scope="col" | Penalty ID
| 9000-30-0
+
!scope="col" | Penalty Code
| FTS International
+
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
| 90.2077
+
| 1
| Water
+
| 07/12/2014
| 100.0
+
| 08/31/2014
| Water
+
| style="text-align: right;" | 7663
| Carrier/Base Fluid
+
| style="text-align: right;" | 17,041,400.0
| 7732-18-5
+
| style="text-align: right;" | 0
| FTS International
 
 
|-
 
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 0.000136189
+
|- valign="top"
| Ammonium persulfate
+
| rowspan="26"| 1
| 95.0
+
| rowspan="6"| CI-150
| APB-1
+
| rowspan="6"| FTS International
| Breaker
+
| rowspan="6"| Acid corrosion inhibitor
| 7727-54-0
+
| Organic amine resin salt
| FTS International
+
| Proprietary
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.000117911
 +
| style="text-align: right;" | 185.885
 
|-
 
|-
 +
| Aromatic aldehyde
 +
| Proprietary
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00003930
 +
| style="text-align: right;" | 61.962
 
|-
 
|-
| 0.00133593
+
| Isopropanol
| Sodium hydroxide
+
| 67-63-0
| 4.0
+
| style="text-align: right;" | 30
| ICI-3240
+
| style="text-align: right;" | 0.000117911
| Biocide
+
| style="text-align: right;" | 185.885
| 1310-73-2
 
| FTS International
 
 
|-
 
|-
 +
| Quaternary ammonium compound
 +
| Proprietary
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00003930
 +
| style="text-align: right;" | 61.962
 
|-
 
|-
| 0.000117911
 
 
| Ethylene glycol
 
| Ethylene glycol
| 30.0
 
| CI-150
 
| Acid corrosion inhibitor
 
 
| 107-21-1
 
| 107-21-1
| FTS International
+
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.000117911
 +
| style="text-align: right;" | 185.885
 
|-
 
|-
 +
| Dimethylformamide
 +
| 68-12-2
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00003930
 +
| style="text-align: right;" | 61.962
 
|-
 
|-
| 3.93038e-05
+
|- valign="top"
| Quaternary ammonium compound
+
| rowspan="2"| ICI-3240
| 10.0
+
| rowspan="2"| FTS International
| CI-150
+
| rowspan="2"| Biocide
| Acid corrosion inhibitor
+
| Dazomet
| Proprietary
+
| 533-74-4
| FTS International
+
| style="text-align: right;" | 24
 +
| style="text-align: right;" | 0.00801557
 +
| style="text-align: right;" | 12636.4
 
|-
 
|-
 +
| Sodium hydroxide
 +
| 1310-73-2
 +
| style="text-align: right;" | 4
 +
| style="text-align: right;" | 0.00133593
 +
| style="text-align: right;" | 2106.06
 
|-
 
|-
| 3.93038e-05
+
|- valign="top"
| Aromatic aldehyde
+
| rowspan="1"| APB-1
| 10.0
+
| rowspan="1"| FTS International
| CI-150
+
| rowspan="1"| Breaker
| Acid corrosion inhibitor
+
| Ammonium persulfate
| Proprietary
+
| 7727-54-0
| FTS International
+
| style="text-align: right;" | 95
 +
| style="text-align: right;" | 0.00013619
 +
| style="text-align: right;" | 214.7
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| HVG-1
 +
| rowspan="4"| FTS International
 +
| rowspan="4"| Gelling agent
 +
| Surfactant
 +
| 68439-51-0
 +
| style="text-align: right;" | 2
 +
| style="text-align: right;" | 0.000188923
 +
| style="text-align: right;" | 297.833
 
|-
 
|-
 +
| Petroleum distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 55
 +
| style="text-align: right;" | 0.00519538
 +
| style="text-align: right;" | 8190.41
 
|-
 
|-
| 3.93038e-05
+
| Clay
| Dimethylformamide
+
| 14808-60-7
| 10.0
+
| style="text-align: right;" | 2
| CI-150
+
| style="text-align: right;" | 0.000188923
| Acid corrosion inhibitor
+
| style="text-align: right;" | 297.833
| 68-12-2
 
| FTS International
 
 
|-
 
|-
 +
| Guar gum
 +
| 9000-30-0
 +
| style="text-align: right;" | 50
 +
| style="text-align: right;" | 0.00472307
 +
| style="text-align: right;" | 7445.83
 
|-
 
|-
| 0.000117911
+
|- valign="top"
| Isopropanol
+
| rowspan="1"| Sand (Proppant)
| 30.0
+
| rowspan="1"| FTS International
| CI-150
+
| rowspan="1"| Proppant
| Acid corrosion inhibitor
+
| Silica Substrate
| 67-63-0
+
| 14808-60-7
| FTS International
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 9.40923
 +
| style="text-align: right;" | 14,833,500.0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Hydrochloric Acid (15%)
 +
| rowspan="1"| FTS International
 +
| rowspan="1"| Acidizing
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.0327095
 +
| style="text-align: right;" | 51565.8
 
|-
 
|-
| 0.000117911
+
|- valign="top"
| Organic amine resin salt
+
| rowspan="1"| Water
| 30.0
+
| rowspan="1"| FTS International
| CI-150
+
| rowspan="1"| Carrier/Base Fluid
| Acid corrosion inhibitor
+
| Water
| Proprietary
+
| 7732-18-5
| FTS International
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 90.2077
 +
| style="text-align: right;" | 142,211,000.0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| CS-500-SI
 +
| rowspan="1"| FTS International
 +
| rowspan="1"| Scale inhibitor
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00263714
 +
| style="text-align: right;" | 4157.39
 
|-
 
|-
| 0.0182731
+
|- valign="top"
 +
| rowspan="3"| FRW-900
 +
| rowspan="3"| FTS International
 +
| rowspan="3"| Friction reducer
 
| Hydrotreated light distillate
 
| Hydrotreated light distillate
| 30.0
 
| FRW-900
 
| Friction reducer
 
 
| 64742-47-8
 
| 64742-47-8
| FTS International
+
| style="text-align: right;" | 30
|-
+
| style="text-align: right;" | 0.0182731
 +
| style="text-align: right;" | 28807.2
 
|-
 
|-
| 0.00609104
 
 
| Alkyl alcohol
 
| Alkyl alcohol
| 10.0
 
| FRW-900
 
| Friction reducer
 
 
| Proprietary
 
| Proprietary
| FTS International
+
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00609104
 +
| style="text-align: right;" | 9602.41
 
|-
 
|-
|-
 
| 0.00304552
 
 
| Oxyalkylated alcohol A
 
| Oxyalkylated alcohol A
| 5.0
 
| FRW-900
 
| Friction reducer
 
 
| Proprietary
 
| Proprietary
| FTS International
+
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00304552
 +
| style="text-align: right;" | 4801.2
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="3"| NE-100
 +
| rowspan="3"| FTS International
 +
| rowspan="3"| Non-emulsifier
 +
| Dodecylbenzenesulfonic acid
 +
| 27176-87-0
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00001703
 +
| style="text-align: right;" | 26.85
 
|-
 
|-
| 9.40923
+
| 2-Butoxyethanol
| Silica Substrate
+
| 111-76-2
| 100.0
+
| style="text-align: right;" | 10
| Sand (Proppant)
+
| style="text-align: right;" | 0.00003406
| Proppant
+
| style="text-align: right;" | 53.7
| 14808-60-7
+
|-
| FTS International
+
| 2-Propanol
 +
| 67-63-0
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00003406
 +
| style="text-align: right;" | 53.7
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FE-100L
 +
| rowspan="1"| FTS International
 +
| rowspan="1"| Iron control
 +
| Citric acid
 +
| 77-92-9
 +
| style="text-align: right;" | 55
 +
| style="text-align: right;" | 0.000721443
 +
| style="text-align: right;" | 1137.34
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| FRW-600
 +
| rowspan="2"| FTS International
 +
| rowspan="2"| Friction reducer
 +
| Ammonium acetate
 +
| 631-61-8
 +
| style="text-align: right;" | 6
 +
| style="text-align: right;" | 0.00195978
 +
| style="text-align: right;" | 3089.55
 +
|-
 +
| Hydrotreated light distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00979891
 +
| style="text-align: right;" | 15447.8
 
|-
 
|-
 
|}
 
|}
For data sources see<ref>{{cite web | title = FracFocus Chemical Disclosure Registry |publisher = [http://www.fracfocusdata.org/DisclosureSearch/]| date = 2015-08-10 | url = http://wellwiki.org/wiki/Well_Chemicals_Data_Sources | accessdate = 2015-08-10 }}</ref>
+
For data sources see<ref>{{cite web
== References ==
+
| title =FracFocus Fracking Chemicals Database
{{reflist}}
+
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 13:30, 15 July 2019

Well Details

Well ID: 37-125-27180
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 145213
Farm/Lease Name: R SMITH 592301
License Status: Active
Spud Date: 12/06/2013
Permit Date: 11/26/2013
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.164789
Longitude: -79.944639

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 EQT PROD CO 0.00 0 0.00 0 0.00 0
2014 EQT PROD CO 404,033.00 70 0.00 0 0.00 0
2015 EQT PROD CO 2,406,829.00 358 0.00 0 0.00 0
2016 EQT PROD CO 2,382,650.00 347 0.00 0 0.00 0
2017 EQT PROD CO 1,243,257.00 353 0.00 0 0.00 0
2018 EQT PROD CO 420,585.00 283 0.00 0 0.00 0
2019 EQT PROD CO 58,267.00 24 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2014-1 Drill Cuttings (in Tons) 457.50 Tons LANDFILL 100277
2014-1 Drill Cuttings (in Tons) 576.66 Tons LANDFILL 100419
2014-2 Fracing Fluid Waste (in Barrels) 7,876.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Fracturing Fluid Waste (in Tons) 47.00 Tons LANDFILL 101571
2014-2 Fracturing Fluid Waste (in Tons) 4.00 Tons LANDFILL SWF 1032-WV0109
2014-2 Produced Fluid (in Barrels) 110.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2014-2 Produced Fluid (in Barrels) 220.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2014-2 Produced Fluid (in Barrels) 9,765.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 80.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2015-1 Produced Fluid (in Barrels) 310.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2015-1 Produced Fluid (in Barrels) 1,430.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015-1 Produced Fluid (in Barrels) 12,321.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Drilling Fluid Waste (in Barrels) 220.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Fracing Fluid Waste (in Barrels) 1,320.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 550.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015-2 Produced Fluid (in Barrels) 6,270.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 899.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016-1 Produced Fluid (in Barrels) RWC 802 9,035.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Other Oil & Gas Wastes (in Barrels) RWC 899 410.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016-2 Produced Fluid (in Barrels) RWC 802 49.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016-2 Produced Fluid (in Barrels) RWC 802 817.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016-2 Produced Fluid (in Barrels) RWC 802 5,149.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Other Oil & Gas Wastes (in Barrels) RWC 899 64.00 Bbl REUSE (AT WELL PAD)
2017-01 Produced Fluid (in Barrels) RWC 802 390.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-01 Produced Fluid (in Barrels) RWC 802 456.00 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-02 Produced Fluid (in Barrels) RWC 802 260.00 Bbl REUSE (AT WELL PAD)
2017-03 Produced Fluid (in Barrels) RWC 802 195.00 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 120.00 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-07 Produced Fluid (in Barrels) RWC 802 370.00 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-08 Produced Fluid (in Barrels) RWC 802 110.00 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 110.00 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 61.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-10 Produced Fluid (in Barrels) RWC 802 12.00 Bbl REUSE (AT WELL PAD)
2017-11 Produced Fluid (in Barrels) RWC 802 3.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-11 Produced Fluid (in Barrels) RWC 802 137.31 Bbl REUSE (AT WELL PAD)
2017-12 Produced Fluid (in Barrels) RWC 802 51.43 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017-12 Produced Fluid (in Barrels) RWC 802 9.17 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017-12 Produced Fluid (in Barrels) RWC 802 137.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-12 Produced Fluid (in Barrels) RWC 802 4.39 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 117.11 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-01 Produced Fluid (in Barrels) RWC 802 1.82 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 18.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-02 Produced Fluid (in Barrels) RWC 802 1.38 Bbl REUSE (AT WELL PAD)
2018-03 Other Oil & Gas Wastes (in Barrels) RWC 899 10.45 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018-03 Other Oil & Gas Wastes (in Barrels) RWC 899 37.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-03 Other Oil & Gas Wastes (in Barrels) RWC 899 2.27 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 19.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-03 Produced Fluid (in Barrels) RWC 802 2.27 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 8.69 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-04 Other Oil & Gas Wastes (in Barrels) RWC 899 5.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-04 Other Oil & Gas Wastes (in Barrels) RWC 899 2.50 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 0.36 Bbl REUSE (AT WELL PAD)
2018-05 Other Oil & Gas Wastes (in Barrels) RWC 899 11.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-05 Other Oil & Gas Wastes (in Barrels) RWC 899 13.18 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 0.31 Bbl REUSE (AT WELL PAD)
2018-06 Other Oil & Gas Wastes (in Barrels) RWC 899 14.09 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-06 Other Oil & Gas Wastes (in Barrels) RWC 899 4.09 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 0.30 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 0.89 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-07 Other Oil & Gas Wastes (in Barrels) RWC 899 0.91 Bbl REUSE (AT WELL PAD)
2018-07 Other Oil & Gas Wastes (in Barrels) RWC 899 5.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-07 Produced Fluid (in Barrels) RWC 802 13.74 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-07 Produced Fluid (in Barrels) RWC 802 10.31 Bbl REUSE (AT WELL PAD)
2018-08 Other Oil & Gas Wastes (in Barrels) RWC 899 5.45 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 4.79 Bbl REUSE (AT WELL PAD)
2018-09 Other Oil & Gas Wastes (in Barrels) RWC 899 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018-09 Other Oil & Gas Wastes (in Barrels) RWC 899 6.36 Bbl REUSE (AT WELL PAD)
2018-09 Other Oil & Gas Wastes (in Barrels) RWC 899 5.45 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-09 Produced Fluid (in Barrels) RWC 802 5.31 Bbl REUSE (AT WELL PAD)
2018-09 Produced Fluid (in Barrels) RWC 802 5.43 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-10 Other Oil & Gas Wastes (in Barrels) RWC 899 23.18 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-10 Other Oil & Gas Wastes (in Barrels) RWC 899 5.00 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 68.06 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 5.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-11 Other Oil & Gas Wastes (in Barrels) RWC 899 5.00 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 10.35 Bbl REUSE (AT WELL PAD)
2018-12 Other Oil & Gas Wastes (in Barrels) RWC 899 3.41 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 3.70 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-12 Produced Fluid (in Barrels) RWC 802 1.77 Bbl REUSE (AT WELL PAD)
2019-01 Other Oil & Gas Wastes (in Barrels) RWC 899 103.63 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 109.96 Bbl REUSE (AT WELL PAD)
2019-02 Other Oil & Gas Wastes (in Barrels) RWC 899 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019-02 Other Oil & Gas Wastes (in Barrels) RWC 899 5.00 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 6.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019-02 Produced Fluid (in Barrels) RWC 802 1.78 Bbl REUSE (AT WELL PAD)
2019-03 Other Oil & Gas Wastes (in Barrels) RWC 899 80.00 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 0.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019-03 Produced Fluid (in Barrels) RWC 802 2.49 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2231137 Primary Facility 12/19/2013 Drilling/Alteration No Violations Noted Alpha-Hunter drilling for EQT using CLS and flare stack . Currently drilling the 592303 well. Cellar and conductor set for this well. Containment under rig and support equipment. No violations at time of inspection.
2265725 Primary Facility 04/24/2014 Drilling/Alteration No Violations Noted Pioneeer 72 drilling for EQT using closed loop system. Currently waiting on cement from 5 1/2 " production casing. Pumped 747 Bbls or cement and 50 Bbls of spacer. for a total of 797 Bbls. 5.5 Bbls returns. KOP @ 5939. Landed curve @ 8454. BOP tested good at nipple up. Containemnt under rig and support equipment in good conition. Site is clean.
2340228 Primary Facility 01/30/2015 Routine/Complete Inspection No Violations Noted Violations for todays inspection linked to site inspection 2340109 enforcement 319619
2343343 Primary Facility 02/10/2015 Routine/Complete Inspection No Violations Noted Well in production. Well in compliance with environmental regulations.
2350348 Primary Facility 02/24/2015 Routine/Complete Inspection No Violations Noted
2361140 Primary Facility 04/14/2015 Routine/Complete Inspection No Violations Noted On April 14th 2015, I inspected the Robert Smith Pad in response to an NOT request and made the following observations:
2363369 Primary Facility 02/10/2015 Routine/Partial Inspection No Violations Noted On 2/10/15 took water samples from well (tap in garage) based on analysis code 946.
2363387 Primary Facility 03/12/2015 Administrative/File Review No Violations Noted On 3/12/15 administrative review of lab results with WQS Bryon Miller did not indicate that gas well activities have impacted the water supply at this time.
2402132 Primary Facility 08/14/2015 Compliance Evaluation No Violations Noted On 8/14/15, I inspected the Robert Smith site as a compliance evaluation inspection in response to the remediation report for a spill occurring on 1/31/15 and made the following observations:
2544056 Primary Facility 2016-09-14 Incident- Response to Accident or Event No Violations Noted On 9/14/16 I performed an incident response inspection at the Robert Smith Site in response to an operator reported spill (CTS ID: 322335) and made the following observations:

•On 9/6/16 EQT Corey Giles reported a spill of 100 gallons of produced fluids to the well pad. The spill was forwarded to the WQS on 9/14/16. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code § 78.54 for failing to control brine and other fluids resulting in discharge to the ground and failure to prevent pollution to the Waters of the Commonwealth. •The spill was cleaned up at the time of inspection with the only observed indicator of the spill location being an area of new gravel on the pad near the production units. No violation. •Well drilling was ongoing at the time of inspection. •During general pad inspection it was noted that multiple production tanks had orange streaking running down their sides from the top of the tanks. The gravel of the pad surface near the containment displayed matching orange stai

2614135 Primary Facility 2017-05-05 Incident- Response to Accident or Event In Compliance with Policy On 5/5/17 an INCDT inspection of the R. Smith well site was conducted in response to CTS ID: 326715. The following was observed:

>> Site was undergoing fracking at time of inspection.

>>The spill in question involved roughly 10 gallons of produced water being sprayed from from an overfilled accessory tank on the pad. Affected pad materials were collected and placed in a waste box on pad for disposal. No violation, site appears to be in compliance with policy.

>>Streaking was again noted on the outside of multiple production tanks similar to streaking noted in previous inspections.

2660111 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:

>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation.

>>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection.

>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation.

>>Drilling was ongoing at the site at the time of inspection.

2691652 Primary Facility 2018-02-02 Routine/Complete Inspection No Violations Noted Well has been fracked and is producing.
2705412 Primary Facility 2018-03-13 Routine/Partial Inspection No Violations Noted On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad. The following was observed:

>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities. No drilling rig was present on site at the time of inspection.

>>Construction of a proposed AST had not begun at the time of inspection.

>>Many water trucks were present on site in association with the attached impoundment.

2737800 Primary Facility 2018-05-16 Incident- Response to Accident or Event No Violations Noted On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18. The following was observed:

>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first. Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection. This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected.

>>Site inspection found no residual evidence of the spill. The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters).

2747127 Primary Facility 2018-06-29 Routine/Partial Inspection No Violations Noted On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident. The following was observed:

>>An unstabilized soil pile near the corner of the pad with a newly improved drain. Controls below the pile were absent though the vegetation was sufficient. No violation, remediation recommended.

>>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road. No controls beyond vegetation were present below the soil pile. No violation, monitoring recommended.

>>An AST was present on the accessory pad.

>>The pad was active at the time of inspection with drilling preparations ongoing. A sound wall was present around the pad perimeter.

2761315 Primary Facility 2018-08-02 Routine/Complete Inspection No Violations Noted On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad. WQSS John Carson accompanied. The following was observed:

>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization. The vegetative strip below remains in good condition. Remediation recommended, no violation.

>>Emptying partially filled containment is encouraged to aid in identifying any possible leaks. No violation.

>>No evidence of excessive or unpermitted runoff from the pad was found.

>>Box in containment appears to be collecting emergency blowdown. If so it should be properly marked. No violation.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 07/12/2014 08/31/2014 7663 17,041,400.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CI-150 FTS International Acid corrosion inhibitor Organic amine resin salt Proprietary 30 0.000117911 185.885
Aromatic aldehyde Proprietary 10 0.00003930 61.962
Isopropanol 67-63-0 30 0.000117911 185.885
Quaternary ammonium compound Proprietary 10 0.00003930 61.962
Ethylene glycol 107-21-1 30 0.000117911 185.885
Dimethylformamide 68-12-2 10 0.00003930 61.962
ICI-3240 FTS International Biocide Dazomet 533-74-4 24 0.00801557 12636.4
Sodium hydroxide 1310-73-2 4 0.00133593 2106.06
APB-1 FTS International Breaker Ammonium persulfate 7727-54-0 95 0.00013619 214.7
HVG-1 FTS International Gelling agent Surfactant 68439-51-0 2 0.000188923 297.833
Petroleum distillate 64742-47-8 55 0.00519538 8190.41
Clay 14808-60-7 2 0.000188923 297.833
Guar gum 9000-30-0 50 0.00472307 7445.83
Sand (Proppant) FTS International Proppant Silica Substrate 14808-60-7 100 9.40923 14,833,500.0
Hydrochloric Acid (15%) FTS International Acidizing Hydrochloric Acid 7647-01-0 15 0.0327095 51565.8
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 90.2077 142,211,000.0
CS-500-SI FTS International Scale inhibitor Ethylene glycol 107-21-1 10 0.00263714 4157.39
FRW-900 FTS International Friction reducer Hydrotreated light distillate 64742-47-8 30 0.0182731 28807.2
Alkyl alcohol Proprietary 10 0.00609104 9602.41
Oxyalkylated alcohol A Proprietary 5 0.00304552 4801.2
NE-100 FTS International Non-emulsifier Dodecylbenzenesulfonic acid 27176-87-0 5 0.00001703 26.85
2-Butoxyethanol 111-76-2 10 0.00003406 53.7
2-Propanol 67-63-0 10 0.00003406 53.7
FE-100L FTS International Iron control Citric acid 77-92-9 55 0.000721443 1137.34
FRW-600 FTS International Friction reducer Ammonium acetate 631-61-8 6 0.00195978 3089.55
Hydrotreated light distillate 64742-47-8 30 0.00979891 15447.8

For data sources see[7]

References