X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-099-22891"

m
m
Line 21: Line 21:
 
| License Status: Producing
 
| License Status: Producing
 
|-
 
|-
| License Date: 2001-07-17
+
| License Date: 2001-02-05
 
|-
 
|-
 
| Spud Date: 2001-03-10
 
| Spud Date: 2001-03-10

Revision as of 07:32, 30 July 2019

Well Details

Well ID: 34-099-22891
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Youngstown
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: CORONADO STEEL-CITY ASHPHALT-TOMRICK REALTY # 3
License Status: Producing
License Date: 2001-02-05
Spud Date: 2001-03-10
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2001-03-14
Well Total Depth: 5186 ft
Configuration: Vertical
Latitude: 41.116828246
Longitude: -80.67152263

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2001-02-05 935 HUTCHESON RH/BOCOR PROD Proposed Formation ORISKANY/CLINTON Issued Date 2/5/01 Expired Date 2/5/02 6:00:00 AM
Original Spud 2001-03-10 RBDMS Rec
Completed 2001-03-14 RBDMS Rec
Reached Total Depth 2001-03-14 RBDMS Rec
Completion Report Received 2001-05-21 RBDMS Rec
Construction Permit Expires 2002-02-05 RBDMS Rec
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-07-17 3408 3418 30
2001-07-17 5030 5076 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1100 Gal 0
H2O 0 67380 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
0 0 0
2001 BOCOR HOLDINGS, LLC 8361 118 200
2002 BOCOR HOLDINGS, LLC 4997 309 365
2003 BOCOR HOLDINGS, LLC 2715 214 365
2004 BOCOR HOLDINGS, LLC 3059 286 365
2005 BOCOR HOLDINGS, LLC 2726 264 365
2006 BOCOR HOLDINGS, LLC 2484 263 365
2007 BOCOR HOLDINGS, LLC 1625 220 365
2008 BOCOR HOLDINGS, LLC 1352 184 365
2009 BOCOR HOLDINGS, LLC 1386 282 365
2012 BOCOR HOLDINGS, LLC 1024 49 366
2013 BOCOR HOLDINGS, LLC 835 180 365
2014 BOCOR HOLDINGS, LLC 525 126 365
2015 BOCOR HOLDINGS, LLC 717 205 359
2016 BOCOR HOLDINGS, LLC 865 185 365
2017 BOCOR HOLDINGS, LLC 584 121 365
2018 BOCOR HOLDINGS, LLC 443 138 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 BOCOR HOLDINGS, LLC Brine 343 200
2002 BOCOR HOLDINGS, LLC Brine 133 365
2003 BOCOR HOLDINGS, LLC Brine 44 365
2004 BOCOR HOLDINGS, LLC Brine 38 365
2005 BOCOR HOLDINGS, LLC Brine 52 365
2006 BOCOR HOLDINGS, LLC Brine 0 365
2007 BOCOR HOLDINGS, LLC Brine 23 365
2008 BOCOR HOLDINGS, LLC Brine 8 365
2009 BOCOR HOLDINGS, LLC Brine 61 365
2012 BOCOR HOLDINGS, LLC Brine 0 366
2013 BOCOR HOLDINGS, LLC Brine 0 365
2014 BOCOR HOLDINGS, LLC Brine 0 365
2015 BOCOR HOLDINGS, LLC Brine 10 359
2016 BOCOR HOLDINGS, LLC Brine 20 365
2017 BOCOR HOLDINGS, LLC Brine 23 365
2018 BOCOR HOLDINGS, LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
001216i277 2002-03-05 Production Wells No Violations Obtained GPS cordinates. No violations this date.
0623366658 2009-09-16 Production Wells No Violations I walked around the tank battery and the wellhead and found that there were no violations at this time.
1644826231 2018-06-21 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-2891. RBDMS indicated reported production was current. Access remained drivable and stable. The well was located within a chain-link fence enclosure. The 8.625 well head was above grade and open to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. A domestic supply connection was present. A stable earthen dike that was free of fluid was present around the production equipment. A chain-link fence enclosure was present on top of the dike. Equipment on location consisted of one (1) vertical mechanical separator, one (1) 210 bbl production tank and one (1) brine tank. The separator remained in good repair. No leaks were observed. The production tank remained in good repair and contained correct identification. Valves were closed and plugged. The brine tank remained in good repair. The inlet valve was closed. No violations were observed during this inspection.
iDIAN00620 2001-08-01 Preliminary Restoration No Violations

For data sources see[9]

References