X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-117-21264"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-117-21264
 
| Well ID: 37-117-21264
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.895217, -77.391556 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.895217, -77.391556 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 08/10/2011
+
| Spud Date: 2011-08-10
 
|-
 
|-
| Permit Date: 6/27/2011
+
| Permit Date: 2011-06-27
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2011-12-21
 +
| 2011-12-21
 +
| style="text-align: right;" | 4947.00
 +
| style="text-align: right;" | 2,855,921.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="17"| 1
 +
| rowspan="1"| SI-112
 +
| rowspan="1"| Clearwater International
 +
| rowspan="1"| Scale Inhibitor
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"|
 +
| rowspan="2"| Shell
 +
| rowspan="2"| Sand
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 12.88
 +
| style="text-align: right;" |
 +
|-
 +
| H2O + Disolved Salts
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 86.51
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="0"| Biocide EC 6116A
 +
| rowspan="0"| Nalco
 +
| rowspan="0"| Acid
 +
|- valign="top"
 +
| rowspan="5"| AI-250
 +
| rowspan="5"| Clearwater International
 +
| rowspan="5"| Acid Inhibitor
 +
| Ethoxylated Nonylphenol
 +
|
 +
| style="text-align: right;" | 13.00
 +
| style="text-align: right;" | 0.00011000
 +
| style="text-align: right;" |
 +
|-
 +
| Fumaric acid
 +
| 110-17-8
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.00009000
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00033000
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00033000
 +
| style="text-align: right;" |
 +
|-
 +
| 2-Butoxyethanol
 +
| 111-76-2
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00033000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="0"|
 +
| rowspan="0"| Shell
 +
| rowspan="0"| Water/Produced Water
 +
|- valign="top"
 +
| rowspan="4"| Biocide EC 6116A
 +
| rowspan="4"| Nalco
 +
| rowspan="4"| Biocide
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00789000
 +
| style="text-align: right;" |
 +
|-
 +
| Dibromoacetonitrile
 +
| 3252-43-5
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00066000
 +
| style="text-align: right;" |
 +
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.05
 +
| style="text-align: right;" |
 +
|-
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00395000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="0"| AI-250
 +
| rowspan="0"| Clearwater International
 +
| rowspan="0"| Gel
 +
|- valign="top"
 +
| rowspan="1"| LEB-10X
 +
| rowspan="1"| Clearwater International
 +
| rowspan="1"| Enzymatic Breaker
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FRP-175
 +
| rowspan="1"| Clearwater International
 +
| rowspan="1"| Friction Reducer
 +
| Polyacrylamide
 +
| 9003-05-8
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00078000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| StimLube W
 +
| rowspan="1"| CESI Chemical
 +
| rowspan="1"| Friction Reducer
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.00995000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Superflo 100
 +
| rowspan="2"| CESI Chemical
 +
| rowspan="2"| Surfactant
 +
| Citrus terpenes
 +
| 94266-47-4
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 156: Line 339:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 14,540.03 Bbl
 
| style="text-align: right;" | 14,540.03 Bbl
Line 162: Line 345:
 
|  
 
|  
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 25.31 Bbl
 
| style="text-align: right;" | 25.31 Bbl
Line 168: Line 351:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 1,110.00 Bbl
 
| style="text-align: right;" | 1,110.00 Bbl
Line 174: Line 357:
 
| WMGR119
 
| WMGR119
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 179.37 Bbl
 
| style="text-align: right;" | 179.37 Bbl
Line 180: Line 363:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 310.60 Bbl
 
| style="text-align: right;" | 310.60 Bbl
Line 186: Line 369:
 
| WMGR123SW018
 
| WMGR123SW018
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 4,587.98 Bbl
 
| style="text-align: right;" | 4,587.98 Bbl
Line 192: Line 375:
 
|  
 
|  
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 198: Line 381:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 37.30 Bbl
 
| style="text-align: right;" | 37.30 Bbl
Line 204: Line 387:
 
| WMGR123SW018
 
| WMGR123SW018
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 79.76 Bbl
 
| style="text-align: right;" | 79.76 Bbl
Line 210: Line 393:
 
|  
 
|  
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 369.97 Bbl
 
| style="text-align: right;" | 369.97 Bbl
Line 216: Line 399:
 
| WMGR119
 
| WMGR119
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 770.41 Bbl
 
| style="text-align: right;" | 770.41 Bbl
Line 222: Line 405:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 166.29 Bbl
 
| style="text-align: right;" | 166.29 Bbl
Line 228: Line 411:
 
| WMGR123SW018
 
| WMGR123SW018
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 5,678.64 Bbl
 
| style="text-align: right;" | 5,678.64 Bbl
Line 234: Line 417:
 
|  
 
|  
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 168.93 Bbl
 
| style="text-align: right;" | 168.93 Bbl
Line 240: Line 423:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 1,608.83 Bbl
 
| style="text-align: right;" | 1,608.83 Bbl
Line 246: Line 429:
 
|  
 
|  
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 3,243.77 Bbl
 
| style="text-align: right;" | 3,243.77 Bbl
Line 252: Line 435:
 
|  
 
|  
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 91.35 Bbl
 
| style="text-align: right;" | 91.35 Bbl
Line 258: Line 441:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 745.00 Bbl
 
| style="text-align: right;" | 745.00 Bbl
Line 264: Line 447:
 
|  
 
|  
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 212.27 Bbl
 
| style="text-align: right;" | 212.27 Bbl
Line 270: Line 453:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 2,485.29 Bbl
 
| style="text-align: right;" | 2,485.29 Bbl
Line 276: Line 459:
 
|  
 
|  
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 99.99 Bbl
 
| style="text-align: right;" | 99.99 Bbl
Line 282: Line 465:
 
| WMGR123NC018
 
| WMGR123NC018
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 62.77 Bbl
 
| style="text-align: right;" | 62.77 Bbl
Line 288: Line 471:
 
| WMGR123SW018
 
| WMGR123SW018
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 199.99 Bbl
 
| style="text-align: right;" | 199.99 Bbl
Line 294: Line 477:
 
|  
 
|  
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,310.00 Bbl
 
| style="text-align: right;" | 1,310.00 Bbl
Line 300: Line 483:
 
|  
 
|  
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 733.33 Bbl
 
| style="text-align: right;" | 733.33 Bbl
Line 306: Line 489:
 
| WMGR123NC018
 
| WMGR123NC018
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,314.67 Bbl
 
| style="text-align: right;" | 1,314.67 Bbl
Line 312: Line 495:
 
|  
 
|  
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 34.17 Bbl
 
| style="text-align: right;" | 34.17 Bbl
Line 318: Line 501:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
Line 324: Line 507:
 
| WMGR123NC018
 
| WMGR123NC018
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,101.00 Bbl
 
| style="text-align: right;" | 1,101.00 Bbl
Line 330: Line 513:
 
|  
 
|  
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,916.67 Bbl
 
| style="text-align: right;" | 1,916.67 Bbl
Line 336: Line 519:
 
|  
 
|  
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Synthetic Liner Materials (in Tons) RWC 806
 
| Synthetic Liner Materials (in Tons) RWC 806
 
| style="text-align: right;" | 1.56 Tons
 
| style="text-align: right;" | 1.56 Tons
Line 342: Line 525:
 
| 301358
 
| 301358
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 133.33 Bbl
 
| style="text-align: right;" | 133.33 Bbl
Line 348: Line 531:
 
|  
 
|  
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 66.66 Bbl
 
| style="text-align: right;" | 66.66 Bbl
Line 354: Line 537:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 166.66 Bbl
 
| style="text-align: right;" | 166.66 Bbl
Line 360: Line 543:
 
|  
 
|  
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 300.00 Bbl
 
| style="text-align: right;" | 300.00 Bbl
Line 366: Line 549:
 
|  
 
|  
 
|-
 
|-
| 2017-04
+
| 2017-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 318.00 Bbl
 
| style="text-align: right;" | 318.00 Bbl
Line 372: Line 555:
 
|  
 
|  
 
|-
 
|-
| 2017-05
+
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 199.98 Bbl
 
| style="text-align: right;" | 199.98 Bbl
Line 378: Line 561:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 233.32 Bbl
 
| style="text-align: right;" | 233.32 Bbl
Line 384: Line 567:
 
|  
 
|  
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 0.09 Bbl
 
| style="text-align: right;" | 0.09 Bbl
Line 390: Line 573:
 
| 7-3115-00193
 
| 7-3115-00193
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 75.00 Bbl
 
| style="text-align: right;" | 75.00 Bbl
Line 396: Line 579:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 402: Line 585:
 
|  
 
|  
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 31.71 Bbl
 
| style="text-align: right;" | 31.71 Bbl
Line 408: Line 591:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 199.99 Bbl
 
| style="text-align: right;" | 199.99 Bbl
Line 414: Line 597:
 
|  
 
|  
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 420: Line 603:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 66.66 Bbl
 
| style="text-align: right;" | 66.66 Bbl
Line 426: Line 609:
 
|  
 
|  
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 223.32 Bbl
 
| style="text-align: right;" | 223.32 Bbl
Line 432: Line 615:
 
|  
 
|  
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| style="text-align: right;" | 0.94 Tons
 
| style="text-align: right;" | 0.94 Tons
Line 438: Line 621:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 109.66 Bbl
 
| style="text-align: right;" | 109.66 Bbl
Line 444: Line 627:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 450: Line 633:
 
|  
 
|  
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 66.66 Bbl
 
| style="text-align: right;" | 66.66 Bbl
Line 456: Line 639:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
Line 462: Line 645:
 
|  
 
|  
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 133.33 Bbl
 
| style="text-align: right;" | 133.33 Bbl
Line 468: Line 651:
 
|  
 
|  
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 474: Line 657:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
Line 480: Line 663:
 
|  
 
|  
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 133.33 Bbl
 
| style="text-align: right;" | 133.33 Bbl
Line 486: Line 669:
 
|  
 
|  
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 133.33 Bbl
 
| style="text-align: right;" | 133.33 Bbl
Line 492: Line 675:
 
|  
 
|  
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.89 Bbl
 
| style="text-align: right;" | 27.89 Bbl
Line 498: Line 681:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 112.33 Bbl
 
| style="text-align: right;" | 112.33 Bbl
Line 504: Line 687:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 510: Line 693:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
Line 516: Line 699:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 522: Line 705:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 66.67 Bbl
 
| style="text-align: right;" | 66.67 Bbl
Line 528: Line 711:
 
|  
 
|  
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 534: Line 717:
 
|  
 
|  
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 0.33 Bbl
 
| style="text-align: right;" | 0.33 Bbl
Line 540: Line 723:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 133.33 Bbl
 
| style="text-align: right;" | 133.33 Bbl
Line 546: Line 729:
 
|  
 
|  
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 31.63 Bbl
 
| style="text-align: right;" | 31.63 Bbl
Line 552: Line 735:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 118.26 Bbl
 
| style="text-align: right;" | 118.26 Bbl
Line 558: Line 741:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 564: Line 747:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 570: Line 753:
 
|  
 
|  
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 71.94 Bbl
 
| style="text-align: right;" | 71.94 Bbl
Line 576: Line 759:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 582: Line 765:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 588: Line 771:
 
|  
 
|  
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 66.66 Bbl
 
| style="text-align: right;" | 66.66 Bbl
Line 594: Line 777:
 
|  
 
|  
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 600: Line 783:
 
|  
 
|  
 
|-
 
|-
| 2019-02
+
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 166.66 Bbl
 
| style="text-align: right;" | 166.66 Bbl
Line 606: Line 789:
 
|  
 
|  
 
|-
 
|-
| 2019-03
+
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 66.33 Bbl
 
| style="text-align: right;" | 66.33 Bbl
Line 631: Line 814:
 
| 2006399
 
| 2006399
 
| Primary Facility
 
| Primary Facility
| 09/22/2011
+
| 2011-09-22
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 638: Line 821:
 
| 2025005
 
| 2025005
 
| Primary Facility
 
| Primary Facility
| 12/08/2011
+
| 2011-12-08
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 645: Line 828:
 
| 2065293
 
| 2065293
 
| Primary Facility
 
| Primary Facility
| 04/09/2012
+
| 2012-04-09
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 652: Line 835:
 
| 2065960
 
| 2065960
 
| Primary Facility
 
| Primary Facility
| 05/08/2012
+
| 2012-05-08
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 659: Line 842:
 
| 2066234
 
| 2066234
 
| Primary Facility
 
| Primary Facility
| 05/09/2012
+
| 2012-05-09
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 666: Line 849:
 
| 2201787
 
| 2201787
 
| Primary Facility
 
| Primary Facility
| 09/03/2013
+
| 2013-09-03
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 673: Line 856:
 
| 2260456
 
| 2260456
 
| Primary Facility
 
| Primary Facility
| 02/11/2014
+
| 2014-02-11
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 758: Line 941:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 12/21/2011
 
| 12/21/2011
 
| style="text-align: right;" | 4947.00
 
| style="text-align: right;" | 2,855,921.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="17"| 1
 
| rowspan="1"| SI-112
 
| rowspan="1"| Clearwater International
 
| rowspan="1"| Scale Inhibitor
 
| Ethylene glycol
 
| 107-21-1
 
| style="text-align: right;" | 40.00
 
| style="text-align: right;" | 0.01
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"|
 
| rowspan="2"| Shell
 
| rowspan="2"| Sand
 
| Quartz
 
| 14808-60-7
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 12.88
 
| style="text-align: right;" |
 
|-
 
| H2O + Disolved Salts
 
|
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 86.51
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="0"| Biocide EC 6116A
 
| rowspan="0"| Nalco
 
| rowspan="0"| Acid
 
|- valign="top"
 
| rowspan="5"| AI-250
 
| rowspan="5"| Clearwater International
 
| rowspan="5"| Acid Inhibitor
 
| Ethoxylated Nonylphenol
 
|
 
| style="text-align: right;" | 13.00
 
| style="text-align: right;" | 0.00011000
 
| style="text-align: right;" |
 
|-
 
| Fumaric acid
 
| 110-17-8
 
| style="text-align: right;" | 7.00
 
| style="text-align: right;" | 0.00009000
 
| style="text-align: right;" |
 
|-
 
| Propargyl alcohol
 
| 107-19-7
 
| style="text-align: right;" | 40.00
 
| style="text-align: right;" | 0.00033000
 
| style="text-align: right;" |
 
|-
 
| Isopropanol
 
| 67-63-0
 
| style="text-align: right;" | 40.00
 
| style="text-align: right;" | 0.00033000
 
| style="text-align: right;" |
 
|-
 
| 2-Butoxyethanol
 
| 111-76-2
 
| style="text-align: right;" | 40.00
 
| style="text-align: right;" | 0.00033000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="0"|
 
| rowspan="0"| Shell
 
| rowspan="0"| Water/Produced Water
 
|- valign="top"
 
| rowspan="4"| Biocide EC 6116A
 
| rowspan="4"| Nalco
 
| rowspan="4"| Biocide
 
| Polyethylene glycol
 
| 25322-68-3
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.00789000
 
| style="text-align: right;" |
 
|-
 
| Dibromoacetonitrile
 
| 3252-43-5
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00066000
 
| style="text-align: right;" |
 
|-
 
| Hydrochloric acid
 
| 7647-01-0
 
| style="text-align: right;" | 15.00
 
| style="text-align: right;" | 0.05
 
| style="text-align: right;" |
 
|-
 
| 2,2-Dibromo-3-nitrilopropionamide
 
| 10222-01-2
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00395000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="0"| AI-250
 
| rowspan="0"| Clearwater International
 
| rowspan="0"| Gel
 
|- valign="top"
 
| rowspan="1"| LEB-10X
 
| rowspan="1"| Clearwater International
 
| rowspan="1"| Enzymatic Breaker
 
| Ethylene glycol
 
| 107-21-1
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.00002000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| FRP-175
 
| rowspan="1"| Clearwater International
 
| rowspan="1"| Friction Reducer
 
| Polyacrylamide
 
| 9003-05-8
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 0.00078000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| StimLube W
 
| rowspan="1"| CESI Chemical
 
| rowspan="1"| Friction Reducer
 
| Distillates, petroleum, hydrotreated light
 
| 64742-47-8
 
| style="text-align: right;" | 20.00
 
| style="text-align: right;" | 0.00995000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| Superflo 100
 
| rowspan="2"| CESI Chemical
 
| rowspan="2"| Surfactant
 
| Citrus terpenes
 
| 94266-47-4
 
| style="text-align: right;" | 15.00
 
| style="text-align: right;" | 0.02
 
| style="text-align: right;" |
 
|-
 
| Isopropanol
 
| 67-63-0
 
| style="text-align: right;" | 15.00
 
| style="text-align: right;" | 0.02
 
| style="text-align: right;" |
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 15:14, 2 August 2019

Well Details

Well ID: 37-117-21264
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Chatham Township
Operator Name: SWEPI LP
Well Pad ID: 149297
Farm/Lease Name: SHOWALTER 822 2H
License Status: Active
Spud Date: 2011-08-10
Permit Date: 2011-06-27
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.895217
Longitude: -77.391556

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-12-21 2011-12-21 4947.00 2,855,921.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SI-112 Clearwater International Scale Inhibitor Ethylene glycol 107-21-1 40.00 0.01
Shell Sand Quartz 14808-60-7 100.00 12.88
H2O + Disolved Salts 100.00 86.51
Biocide EC 6116A Nalco Acid
AI-250 Clearwater International Acid Inhibitor Ethoxylated Nonylphenol 13.00 0.00011000
Fumaric acid 110-17-8 7.00 0.00009000
Propargyl alcohol 107-19-7 40.00 0.00033000
Isopropanol 67-63-0 40.00 0.00033000
2-Butoxyethanol 111-76-2 40.00 0.00033000
Shell Water/Produced Water
Biocide EC 6116A Nalco Biocide Polyethylene glycol 25322-68-3 60.00 0.00789000
Dibromoacetonitrile 3252-43-5 5.00 0.00066000
Hydrochloric acid 7647-01-0 15.00 0.05
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00395000
AI-250 Clearwater International Gel
LEB-10X Clearwater International Enzymatic Breaker Ethylene glycol 107-21-1 60.00 0.00002000
FRP-175 Clearwater International Friction Reducer Polyacrylamide 9003-05-8 100.00 0.00078000
StimLube W CESI Chemical Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 20.00 0.00995000
Superflo 100 CESI Chemical Surfactant Citrus terpenes 94266-47-4 15.00 0.02
Isopropanol 67-63-0 15.00 0.02

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 243,546.54 290 0.00 0 0.00 0
2013 SWEPI LP 200,025.70 326 0.00 0 0.00 0
2014 SWEPI LP 133,700.56 269 0.00 0 0.00 0
2015 SWEPI LP 128,737.68 155 0.00 0 0.00 0
2016 SWEPI LP 114,787.68 147 0.00 0 0.00 0
2017 SWEPI LP 110,305.97 168 0.00 0 0.00 0
2018 SWEPI LP 97,378.25 226 0.00 0 0.00 0
2019 SWEPI LP 26,543.74 61 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S01 Produced Fluid (in Barrels) 14,540.03 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Drilling Fluid Waste (in Barrels) 25.31 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-S02 Fracing Fluid Waste (in Barrels) 1,110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012-S02 Fracing Fluid Waste (in Barrels) 179.37 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-S02 Fracing Fluid Waste (in Barrels) 310.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012-S02 Fracing Fluid Waste (in Barrels) 4,587.98 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Produced Fluid (in Barrels) 33.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-S02 Produced Fluid (in Barrels) 37.30 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012-S02 Produced Fluid (in Barrels) 79.76 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Produced Fluid (in Barrels) 369.97 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013-S01 Produced Fluid (in Barrels) 770.41 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-S01 Produced Fluid (in Barrels) 166.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013-S01 Produced Fluid (in Barrels) 5,678.64 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracing Fluid Waste (in Barrels) 168.93 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-S02 Fracing Fluid Waste (in Barrels) 1,608.83 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 3,243.77 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Fracing Fluid Waste (in Barrels) 91.35 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-S01 Fracing Fluid Waste (in Barrels) 745.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 212.27 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-S01 Produced Fluid (in Barrels) 2,485.29 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 99.99 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014-S02 Produced Fluid (in Barrels) 62.77 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014-S02 Produced Fluid (in Barrels) 199.99 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 1,310.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 733.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015-S02 Produced Fluid (in Barrels) 1,314.67 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 34.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016-S01 Produced Fluid (in Barrels) RWC 802 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-S01 Produced Fluid (in Barrels) RWC 802 1,101.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 1,916.67 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Synthetic Liner Materials (in Tons) RWC 806 1.56 Tons LANDFILL 301358
2017-M01 Produced Fluid (in Barrels) RWC 802 133.33 Bbl REUSE (AT WELL PAD)
2017-M02 Produced Fluid (in Barrels) RWC 802 66.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M02 Produced Fluid (in Barrels) RWC 802 166.66 Bbl REUSE (AT WELL PAD)
2017-M03 Produced Fluid (in Barrels) RWC 802 300.00 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 318.00 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 199.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M06 Produced Fluid (in Barrels) RWC 802 233.32 Bbl REUSE (AT WELL PAD)
2017-M07 Other Oil & Gas Wastes (in Barrels) RWC 899 0.09 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2017-M07 Produced Fluid (in Barrels) RWC 802 75.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M07 Produced Fluid (in Barrels) RWC 802 50.00 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 31.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M08 Produced Fluid (in Barrels) RWC 802 199.99 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M09 Produced Fluid (in Barrels) RWC 802 66.66 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 223.32 Bbl REUSE (AT WELL PAD)
2017-M10 Waste Water Treatment Sludge (in Tons) RWC 804 0.94 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-M11 Produced Fluid (in Barrels) RWC 802 109.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M11 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2017-M12 Produced Fluid (in Barrels) RWC 802 66.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M12 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2018-M01 Produced Fluid (in Barrels) RWC 802 133.33 Bbl REUSE (AT WELL PAD)
2018-M02 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M02 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 133.33 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 133.33 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 27.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-M05 Produced Fluid (in Barrels) RWC 802 112.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M06 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M06 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M07 Produced Fluid (in Barrels) RWC 802 66.67 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 0.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M09 Produced Fluid (in Barrels) RWC 802 133.33 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 31.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-M10 Produced Fluid (in Barrels) RWC 802 118.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M10 Produced Fluid (in Barrels) RWC 802 25.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M10 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 71.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M11 Produced Fluid (in Barrels) RWC 802 25.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M11 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 66.66 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 166.66 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 66.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2006399 Primary Facility 2011-09-22 Routine/Complete Inspection No Violations Noted Well not spudded as of 9/22/2011
2025005 Primary Facility 2011-12-08 Routine/Complete Inspection No Violations Noted
2065293 Primary Facility 2012-04-09 Routine/Complete Inspection No Violations Noted
2065960 Primary Facility 2012-05-08 Routine/Complete Inspection No Violations Noted
2066234 Primary Facility 2012-05-09 Routine/Partial Inspection No Violations Noted A routine partial inspection was conducted at the Showalter pad on 5/9/12. The last inspection conducted on behalf of the operator was on 5/7/12 by Penn E&R. There was 17 wheelie tanks on-site and they were on containment. Several puddles on the pad (not on containment) were screened for elevated conductivity, none exhibited high readings. One area on containment had a reading of 4.27 mS. This was located near the wheelie tank N37013. There were multiple holes observed in the liner, but none in the area of the elevated reading. The cause of the elevated reading should be determined and corrected. The liquid on the liner should be collected and disposed of properly. The integrity of the liner should be retired as soon as possible. No erosion issued were observed during this inspection. No new violations were cited during this inspection. - MRN
2201787 Primary Facility 2013-09-03 Routine/Partial Inspection No Violations Noted An inspection of the Showalter 822 site in Chatham Township, Tioga County was conducted on September 3, 2013. The last inspection conducted on behalf of the operator was on 8/19/2013. The 1H, 2H and 4H wells were drilled and appeared to be in production, one additional well was spudded. No puddles exhibiting elevated conductivity or erosion issues were observed at this time. All area were well vegetated or otherwise stabilized, no issues were noted. No violations were cited during this inspection
2260456 Primary Facility 2014-02-11 Drilling/Alteration No Violations Noted
2442844 Primary Facility 2016-01-20 Complaint Inspection No Violations Noted The Department inspected the SWEPI LP site – Showalter 822 (ESX11-117-0011) located in Chatham Twp., Tioga Co. on 1/20/2016 @ 1115 hours. The weather was 18° and overcast with blustery winds and a dusting of snow and ice. A copy of the E&S plan was located in the mailbox along with the onsite inspection log, well permits and PPC Plan. The site was last inspected by company personnel on 1/14/2016 with “site snow covered” listed in the comments section. Total Project area is listed as 20.20 acres. The receiving stream is listed as “UNT to Crooked Creek/Susquehanna River Basin in PA” WWF designation.
2636096 Primary Facility 2017-09-14 Routine/Partial Inspection No Violations Noted EC readings with Oakton PCSTestr 35 (mS/cm): pad--0.25, containment--0.48.
2696044 Primary Facility 2018-02-20 Routine/Partial Inspection No Violations Noted Electrical conductivity (EC) readings taken with an Oakton PCSTestr 35. Puddle on pad gave a 0.25 mS/cm reading. Inspection logbook is in mailbox near production tank; last inspection listed February 17, 2018. Air temp 62F. JLP
2729677 Primary Facility 2018-05-14 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the SWEPI LP-Showalter 822 Well Pad located in Chatham Township, Tioga County on May 14, 2018 at 1300 hrs. the weather was 73° and sunny. Winds WSW @9 mph, 53% humidity.

The current ESCGP-2 authorizes the expansion of the existing well pad by adding a 41,241 ft² section to the west, northwest, and south west side of the pad as well as the addition of a 200'x 200' tank pad. The well pad was previously in interim restoration with 4 wells observed drilled, 3 of which appear to be in production.

As of today's inspection contractor JL watts is in the process of expanding the pad. Temporary erosion and sediment control's appear to be installed as specified in the plan drawings. No erosion or sedimentation was observed.

No violations were noted at this time. Please contact me with any questions. I departed the site at 1420 hrs.

-ELN

2775762 Primary Facility 2018-09-17 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the SWEPI LP - Showalter 822 well pad located in Chatham Twp, Tioga Co. on 917/2018 @1245 hours. The weather was 72 degrees and cloudy, winds N @11mph, 94% humidity. Present for the inspection was myself and Korey Starkey, DEP Env Trainee.

The access road, well pad, and E&S controls were observed. The current ESCGP-2 authorized the expansion of the existing well pad by adding a 41,241 ft² section to the west, northwest, and south west side of the pad as well as the addition of a 200'x 200' tank pad.

The well pad was previously in interim restoration with 4 wells observed drilled, 3 of which appear to be in production. 4 new well cellars were observed on the pad surface. An infiltration basin was observed below the north side of the well pad. Temporary BMPs were observed in the form of CFS below the newly constructed pony pad and below the pad expansion area. No erosion or sedimentation was observed onsite.

The site was last inspected by company on 9/15/2018 with n

For data sources see[7]

References