Revision as of 15:22, 14 August 2019

Well Details

Well ID: 34-155-23783
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: SHERIDAN UNIT
License Status: Producing
License Date: 2005-04-12
Spud Date: 2005-07-20
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-07-25
Well Total Depth: 5359 ft
Configuration: Vertical
Latitude: 41.161629482
Longitude: -80.54086793

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-04-12 Proposed Formations:CLINTON/MEDINA, Issued Date:4/12/2005, Expired Date:4/12/2006 6:00:00 AM, Drilling unit acres:41.53, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-07-20 RBDMS Rec
Completed 2005-07-25 RBDMS Rec
Reached Total Depth 2005-07-25 RBDMS Rec
Completion Report Received 2005-11-17 RBDMS Rec
Construction Permit Expires 2006-04-12 RBDMS Rec
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-01-13 5074 5231 79

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 76210 Gal 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
0 0 0
2005 BOCOR HOLDINGS, LLC 43 0 365
2006 BOCOR HOLDINGS, LLC 30656 548 365
2007 BOCOR HOLDINGS, LLC 17439 317 365
2008 BOCOR HOLDINGS, LLC 11470 170 365
2009 BOCOR HOLDINGS, LLC 8792 169 365
2010 BOCOR HOLDINGS, LLC 6916 86 365
2011 BOCOR HOLDINGS, LLC 7779 153 365
2012 BOCOR HOLDINGS, LLC 6936 103 366
2013 BOCOR HOLDINGS, LLC 5072 93 365
2014 BOCOR HOLDINGS, LLC 4088 57 365
2015 BOCOR HOLDINGS, LLC 4073 93 369
2016 BOCOR HOLDINGS, LLC 3858 93 365
2017 BOCOR HOLDINGS, LLC 3655 77 365
2018 BOCOR HOLDINGS, LLC 3314 38 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 BOCOR HOLDINGS, LLC Brine 65 365
2006 BOCOR HOLDINGS, LLC Brine 65 365
2007 BOCOR HOLDINGS, LLC Brine 109 365
2008 BOCOR HOLDINGS, LLC Brine 0 365
2009 BOCOR HOLDINGS, LLC Brine 32 365
2010 BOCOR HOLDINGS, LLC Brine 25 365
2011 BOCOR HOLDINGS, LLC Brine 0 365
2012 BOCOR HOLDINGS, LLC Brine 0 366
2013 BOCOR HOLDINGS, LLC Brine 0 365
2014 BOCOR HOLDINGS, LLC Brine 0 365
2015 BOCOR HOLDINGS, LLC Brine 0 369
2016 BOCOR HOLDINGS, LLC Brine 0 365
2017 BOCOR HOLDINGS, LLC Brine 0 365
2018 BOCOR HOLDINGS, LLC Brine 45 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0847545873 2012-01-11 Production Wells No Violations There were no violations at the time of inspection.
1383175203 2013-08-26 UrbanProduction Wells No Violations My inspection found the well in production. The well was equipped with a plunger lift unit and a domestic gas line. The tank battery contained a 100 barrel production tank, a 50 barrel brine tank, and a vertical separator. There were plugs on the load lines. There was no safety equipment on the production tank. There were chain link fences around the tank battery and well with locks that did not work. The dike met containment requirements. A 16 day production chart was located at the separator. An identification sign was properly posted. The lease road was in good condition. I called Todd Sutko at 330-506-2531. I instructed him to install the safety equipment, an identification sign at the well, and new locks.
1404927390 2014-07-09 UrbanPreliminary Restoration No Violations I was on location to perform an urban preliminary restoration. I found during my inspection the site graded. Vegetation was well established. The well was in production and equipped with a plunger lift unit. The tank battery consisted of a 100 barrel production tank, a 50 barrel, poly tank and a separator. There was a dike surrounding the tank battery. Identification signs were properly posted at the well and tank battery. Locked, chain link fences surrounded the well and tank battery. The lease road was in good condition. All drilling equipment was removed. All debris was removed. The pits were closed. Urban Preliminary Restoration passed.

For data sources see[9]