If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 9: | Line 9: | ||
| State: Ohio | | State: Ohio | ||
|- | |- | ||
− | | County: | + | | County: <County> |
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Paint Township,_Wayne_County,_Ohio|Paint Township]] |
|- | |- | ||
| Operator Name: [[MFC DRILLING INC]] | | Operator Name: [[MFC DRILLING INC]] |
Well ID: 34-169-21963 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.699675012,"lon":-81.68056017,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: Paint Township | |
Operator Name: MFC DRILLING INC | |
Well Pad ID: | |
Farm/Lease Name: HINER ETAL UNIT | |
License Status: Producing | |
License Date: 1977-05-18 | |
Spud Date: 1977-06-17 | |
Spud Drilling Contractor: | |
Final Drill Date: 1977-08-16 | |
Well Total Depth: 4400 ft | |
Configuration: Vertical | |
Latitude: 40.699675012 | |
Longitude: -81.68056017 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1977-05-18 | 169 SMAIL JAMES R GeoDate 5/18/77 |
Original Spud | 1977-06-17 | |
Completed | 1977-08-16 | |
Reached Total Depth | 1977-08-16 | |
Change of Owner | 2000-12-12 | Operator changed from 169, SMAIL JAMES R INC to 3059, MFC DRILLING INC |
Record Last Modified | 2019-06-04 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4008 | 4265 | 1 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 2225 Bbl | 70000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | RSC ENERGY CORP | 1714 | 0 | 0 |
1985 | CARLESS RESOURCES INC | 3799 | 0 | 365 |
1986 | CARLESS RESOURCES INC | 3091 | 0 | 365 |
1987 | CARLESS RESOURCES INC | 1128 | 62 | 120 |
1991 | JAMES R SMAIL INC | 3430 | 0 | 365 |
1992 | JAMES R SMAIL INC | 1926 | 0 | 365 |
1993 | JAMES R SMAIL INC | 1586 | 0 | 365 |
1994 | JAMES R SMAIL INC | 706 | 0 | 365 |
1995 | JAMES R SMAIL INC | 405 | 0 | 365 |
1996 | JAMES R SMAIL INC | 428 | 22 | 365 |
1997 | JAMES R SMAIL INC | 338 | 0 | 365 |
1998 | JAMES R SMAIL INC | 314 | 0 | 365 |
1999 | JAMES R SMAIL INC | 289 | 0 | 365 |
2000 | JAMES R SMAIL INC | 247 | 0 | 365 |
2001 | MFC DRILLING INC | 109 | 0 | 365 |
2002 | MFC DRILLING INC | 2657 | 0 | 365 |
2003 | MFC DRILLING INC | 1476 | 0 | 365 |
2004 | MFC DRILLING INC | 1936 | 0 | 365 |
2005 | MFC DRILLING INC | 2058 | 0 | 365 |
2006 | MFC DRILLING INC | 2142 | 0 | 365 |
2007 | MFC DRILLING INC | 2021 | 0 | 365 |
2008 | MFC DRILLING INC | 2248 | 1286 | 365 |
2009 | MFC DRILLING INC | 2283 | 0 | 365 |
2010 | MFC DRILLING INC | 2071 | 0 | 365 |
2011 | MFC DRILLING INC | 2090 | 0 | 365 |
2012 | MFC DRILLING INC | 2181 | 0 | 366 |
2013 | MFC DRILLING INC | 1759 | 0 | 365 |
2014 | MFC DRILLING INC | 1142 | 0 | 365 |
2015 | MFC DRILLING INC | 831 | 0 | 365 |
2016 | MFC DRILLING INC | 552 | 0 | 365 |
2017 | MFC DRILLING INC | 533 | 0 | 365 |
2018 | MFC DRILLING INC | 494 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | RSC ENERGY CORP | Brine | 0 | 0 |
1985 | CARLESS RESOURCES INC | Brine | 0 | 365 |
1986 | CARLESS RESOURCES INC | Brine | 0 | 365 |
1987 | CARLESS RESOURCES INC | Brine | 0 | 120 |
1991 | JAMES R SMAIL INC | Brine | 0 | 365 |
1992 | JAMES R SMAIL INC | Brine | 0 | 365 |
1993 | JAMES R SMAIL INC | Brine | 0 | 365 |
1994 | JAMES R SMAIL INC | Brine | 0 | 365 |
1995 | JAMES R SMAIL INC | Brine | 0 | 365 |
1996 | JAMES R SMAIL INC | Brine | 0 | 365 |
1997 | JAMES R SMAIL INC | Brine | 0 | 365 |
1998 | JAMES R SMAIL INC | Brine | 0 | 365 |
1999 | JAMES R SMAIL INC | Brine | 365 | |
2000 | JAMES R SMAIL INC | Brine | 365 | |
2001 | MFC DRILLING INC | Brine | 298 | 365 |
2002 | MFC DRILLING INC | Brine | 212 | 365 |
2003 | MFC DRILLING INC | Brine | 0 | 365 |
2004 | MFC DRILLING INC | Brine | 112 | 365 |
2005 | MFC DRILLING INC | Brine | 44 | 365 |
2006 | MFC DRILLING INC | Brine | 0 | 365 |
2007 | MFC DRILLING INC | Brine | 0 | 365 |
2008 | MFC DRILLING INC | Brine | 0 | 365 |
2009 | MFC DRILLING INC | Brine | 0 | 365 |
2010 | MFC DRILLING INC | Brine | 0 | 365 |
2011 | MFC DRILLING INC | Brine | 0 | 365 |
2012 | MFC DRILLING INC | Brine | 0 | 366 |
2013 | MFC DRILLING INC | Brine | 45 | 365 |
2014 | MFC DRILLING INC | Brine | 70 | 365 |
2015 | MFC DRILLING INC | Brine | 40 | 365 |
2016 | MFC DRILLING INC | Brine | 0 | 365 |
2017 | MFC DRILLING INC | Brine | 0 | 365 |
2018 | MFC DRILLING INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0085455225 | 2013-12-26 | Production Wells | No Violations | This producing pumping unit well has no apparent problems at time of inspection. |
1116276542 | 2017-02-24 | Production Wells | No Violations | Inspected production well on 02/24/2017. The tank battery consists of 1-100 bbl steel tank and 1-horizontal separator, located within a partial-earthen dike; the dike needs built-up on the back side and east side in order to effectively serve as containment in the case of a spill. Jeff Harmon, with MFC Drilling, was notified of this issue and will have it addressed promptly. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No other problems were noted at the time of the inspection. |
1297117931 | 2015-09-16 | Production Wells | No Violations | This is a pumping unit well. There are no apparent problems nor compliance issues at this time. |
1388062732 | 2013-12-24 | Production Wells | No Violations | This producing pumping unit well has no apparent problems at this time. |
1402904496 | 2013-01-09 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
1472124454 | 2016-08-22 | Production Wells | No Violations | Inspected production well on 08/22/2016. The tank battery consists of 1-100 bbl steel tank and 1-horizontal separator, located within a shallow earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
1518110896 | 2018-05-29 | Production Wells | No Violations | Inspected production well on 05/29/2018. The tank battery consists of 1-100 bbl steel tank, 1-horizontal separator, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor, and a meter with a regulator. No problems were noted at the time of the inspection. |
For data sources see[9]