Difference between revisions of "34-169-25172"

m
m
Line 9: Line 9:
 
| State: Ohio
 
| State: Ohio
 
|-
 
|-
| County: [[Wayne_County,_Ohio|Wayne]]
+
| County: <County>
 
|-
 
|-
| Municipality: [[Canaan_Township,_Wayne_County,_Ohio|Canaan Township]]
+
| Municipality: [[Canaan Township,_Wayne_County,_Ohio|Canaan Township]]
 
|-
 
|-
 
| Operator Name: [[KENOIL LLC]]
 
| Operator Name: [[KENOIL LLC]]

Revision as of 21:58, 14 August 2019

Well Details

Well ID: 34-169-25172
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality: Canaan Township
Operator Name: KENOIL LLC
Well Pad ID:
Farm/Lease Name: BLOUGH/HOOKWAY UNIT # 1
License Status: Producing
License Date: 1997-05-09
Spud Date: 1997-05-27
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1997-06-02
Well Total Depth: 5605 ft
Configuration: Vertical
Latitude: 40.932242350
Longitude: -81.92156387

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1997-05-09 627 KENOIL GeoDt 5/9/97
Oil and Gas 1997-05-09 Issued Date 5/9/97 Expired Date 5/9/98 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON/TPLU Proposed Depth Proposed Drill Depth
Original Spud 1997-05-27 RBDMS Rec
Completed 1997-06-02 RBDMS Rec
Reached Total Depth 1997-06-02 RBDMS Rec
Completion Report Received 1997-10-16 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-12-15 5522 5540 38
1997-12-15 5546 5556 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1500 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1997 KENOIL LLC 3334 6757 365
1998 KENOIL LLC 20446 10740 365
1999 KENOIL LLC 11332 6310 0
2000 KENOIL LLC 11024 3960 365
2001 KENOIL LLC 7448 3043 365
2002 KENOIL LLC 6244 1970 365
2003 KENOIL LLC 6684 1967 365
2004 KENOIL LLC 4075 1789 365
2005 KENOIL LLC 4347 2052 365
2006 KENOIL LLC 4285 1773 365
2007 KENOIL LLC 3724 1874 365
2008 KENOIL LLC 3212 1729 365
2009 KENOIL LLC 1761 1480 365
2010 KENOIL LLC 1446 1453 365
2011 KENOIL LLC 1292 1397 0
2012 KENOIL LLC 1951 1202 366
2013 KENOIL LLC 1658 1415 365
2014 KENOIL LLC 1866 1387 365
2015 KENOIL LLC 1262 1018 365
2016 KENOIL LLC 1000 1080 365
2017 KENOIL LLC 730 1128 365
2018 KENOIL LLC 1076 1267 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1997 KENOIL LLC Brine 1135 365
1998 KENOIL LLC Brine 0 365
1999 KENOIL LLC Brine 4
2000 KENOIL LLC Brine 365
2001 KENOIL LLC Brine 0 365
2002 KENOIL LLC Brine 0 365
2003 KENOIL LLC Brine 0 365
2004 KENOIL LLC Brine 0 365
2005 KENOIL LLC Brine 0 365
2006 KENOIL LLC Brine 0 365
2007 KENOIL LLC Brine 0 365
2008 KENOIL LLC Brine 0 365
2009 KENOIL LLC Brine 0 365
2010 KENOIL LLC Brine 30 365
2011 KENOIL LLC Brine 0
2012 KENOIL LLC Brine 0 366
2013 KENOIL LLC Brine 0 365
2014 KENOIL LLC Brine 0 365
2015 KENOIL LLC Brine 0 365
2016 KENOIL LLC Brine 0 365
2017 KENOIL LLC Brine 0 365
2018 KENOIL LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0097432087 2017-01-26 Production Wells No Violations Inspected production well on 01/26/2017. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike; the diked area is shared with the tank battery for the Blough #1 well (PN: 169-21881). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The pump jack itself is located within an unlocked metal fence. No problems were noted at the time of the inspection.
0202766348 2017-01-26 Preliminary Restoration No Violations Inspected production well on 01/26/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0268780919 2014-06-13 Production Wells No Violations Pumping unit well with no apparent problems.
0512133375 2016-10-26 Preliminary Restoration No Violations Inspected production well on 10/26/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0531149568 2016-10-26 Production Wells No Violations Inspected production well on 10/26/2016. The tank battery consists of 4-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, located within an unlocked metal fence. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1602085754 2013-06-14 Production Wells No Violations This is a pump jack well. No apparent problems at this time.
1768035186 2018-02-09 Production Wells No Violations Inspected production well on 02/09/2018. The tank battery consists of 2-100 bbl steel tanks, 1-vertical separator (shared), 1-drip (shared), and 1-meter box (shared), located within an earthen dike; the diked area and noted equipment is shared with the Blough #1 well (PN: 169-21881). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor, located within an unlocked metal fence. No problems were noted at the time of the inspection.
1869244180 2015-10-08 Production Wells No Violations Inspected production well on 10/08/2015. The tank battery consists of 4-100 bbl steel tanks and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor located within an unlocked metal fence. The well was pumping at the time of the inspection. No problems were noted at the time of the inspection.
1993614241 2015-08-19 Production Wells No Violations This is a producing pumping unit well. There are no apparent problems nor compliance issues at this time.
iANGE00063 1997-10-23 Preliminary Restoration No Violations

For data sources see[9]

References