| Well ID: 37-005-30588 | | Well ID: 37-005-30588 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.677947, -79.381414 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 05 | + | | Spud Date: 2010-05-09 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2010-04-05 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | <!--== Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 160: | Line 185: | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
+ | !scope="col" | Operator | ||
!scope="col" | Waste Type | !scope="col" | Waste Type | ||
!scope="col" | Quantity | !scope="col" | Quantity | ||
Line 165: | Line 191: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2010- | + | | 2010 |
+ | | [[EQT PROD CO]] | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 200.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | PA0091472 | ||
+ | |- | ||
+ | | 2010 | ||
+ | | [[EQT PROD CO]] | ||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 7,680.00 Bbl | | style="text-align: right;" | 7,680.00 Bbl | ||
Line 171: | Line 205: | ||
| 301353 | | 301353 | ||
|- | |- | ||
− | | 2010 | + | | 2010 |
+ | | [[EQT PROD CO]] | ||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 3,610.00 Bbl | | style="text-align: right;" | 3,610.00 Bbl | ||
Line 177: | Line 212: | ||
| PA0091472 | | PA0091472 | ||
|- | |- | ||
− | | 2010 | + | | 2010 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Drilling Fluid Waste (in Barrels) |
− | | | + | | style="text-align: right;" | 0.00 Bbl |
− | | | + | | IDENTIFY METHOD IN COMMENTS |
+ | | | ||
|- | |- | ||
− | | 2010 | + | | 2010 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 210.00 Bbl | | style="text-align: right;" | 210.00 Bbl | ||
Line 189: | Line 226: | ||
| PA0095273 | | PA0095273 | ||
|- | |- | ||
− | | | + | | 2011 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid (in Barrels) |
− | | | + | | style="text-align: right;" | 750.00 Bbl |
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2011 | + | | 2011 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 907.00 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-049-23127 |
|- | |- | ||
− | | 2011 | + | | 2011 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 420.00 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-009-22704 |
|- | |- | ||
− | | 2011 | + | | 2011 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 119.00 Bbl | | style="text-align: right;" | 119.00 Bbl | ||
Line 219: | Line 254: | ||
| 34-167-28466 | | 34-167-28466 | ||
|- | |- | ||
− | | 2011- | + | | 2011 |
+ | | [[EQT PROD CO]] | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 200.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | 301353 | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 360.00 Bbl | | style="text-align: right;" | 360.00 Bbl | ||
Line 225: | Line 268: | ||
| PA0091472 | | PA0091472 | ||
|- | |- | ||
− | | 2011-1 | + | | 2011 |
+ | | [[EQT PROD CO]] | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 1,934.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW001 | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[EQT PROD CO]] | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 120.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-009-22704 | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[EQT PROD CO]] | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 1,410.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-083-24137 | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 690.00 Bbl | | style="text-align: right;" | 690.00 Bbl | ||
Line 231: | Line 296: | ||
| PA0095273 | | PA0095273 | ||
|- | |- | ||
− | | 2011 | + | | 2011 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Fracing Fluid Waste (in Barrels) |
− | | | + | | style="text-align: right;" | 329.00 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
+ | | WMGR119 | ||
|- | |- | ||
− | | 2011 | + | | 2011 |
+ | | [[EQT PROD CO]] | ||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 467.00 Bbl | | style="text-align: right;" | 467.00 Bbl | ||
Line 243: | Line 310: | ||
| 34-007-24523 | | 34-007-24523 | ||
|- | |- | ||
− | | 2011 | + | | 2011 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid (in Barrels) |
+ | | style="text-align: right;" | 240.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | 34-121-23390 |
|- | |- | ||
− | | 2011 | + | | 2011 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Drilling Fluid Waste (in Barrels) |
+ | | style="text-align: right;" | 200.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | PA0095443 |
|- | |- | ||
− | | 2011 | + | | 2011 |
+ | | [[EQT PROD CO]] | ||
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 332.00 Bbl | | style="text-align: right;" | 332.00 Bbl | ||
Line 261: | Line 331: | ||
| 34-007-24523 | | 34-007-24523 | ||
|- | |- | ||
− | | 2011 | + | | 2011 |
+ | | [[EQT PROD CO]] | ||
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 10,250.00 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 92.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | 525-1 |
|- | |- | ||
− | | | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 5,496.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-083-24137 |
|- | |- | ||
− | | | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 299.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-133-22523 |
|- | |- | ||
− | + | | 2012 | |
− | + | | [[EQT PROD CO]] | |
− | |||
− | |||
− | |||
− | |||
− | | 2012 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 100,344.00 Bbl | | style="text-align: right;" | 100,344.00 Bbl | ||
Line 315: | Line 366: | ||
| | | | ||
|- | |- | ||
− | | 2012 | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 949.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-007-24355 |
|- | |- | ||
− | | 2012 | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 87.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-151-21198 |
|- | |- | ||
− | | 2012 | + | | 2012 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 80.00 Bbl | | style="text-align: right;" | 80.00 Bbl | ||
Line 339: | Line 387: | ||
| 34-167-29577 | | 34-167-29577 | ||
|- | |- | ||
− | | 2012 | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 566.00 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-21447 |
|- | |- | ||
− | | 2012 | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 368.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-121-2-3995 |
|- | |- | ||
− | | 2012 | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 437.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-167-28466 |
|- | |- | ||
− | | 2012 | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 2,597.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
|- | |- | ||
− | | 2012 | + | | 2012 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 739.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-121-23995 |
|- | |- | ||
− | | 2012 | + | | 2012 |
− | + | | [[EQT PROD CO]] | |
− | | | + | | Drilling Fluid Waste (in Barrels) |
− | + | | style="text-align: right;" | 5,164.00 Bbl | |
− | |||
− | |||
− | |||
− | | | ||
− | | style="text-align: right;" | | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2013 | + | | 2013 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 581.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-21447 |
|- | |- | ||
− | | 2013 | + | | 2013 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 110.00 Bbl | | style="text-align: right;" | 110.00 Bbl | ||
Line 399: | Line 443: | ||
| 34-059-24067 | | 34-059-24067 | ||
|- | |- | ||
− | | 2013 | + | | 2013 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 100.00 Bbl | | style="text-align: right;" | 100.00 Bbl | ||
Line 405: | Line 450: | ||
| 34-155-21438 | | 34-155-21438 | ||
|- | |- | ||
− | | 2013 | + | | 2013 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 110.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-013-20609 |
|- | |- | ||
− | | 2013 | + | | 2013 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 5,172.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | + | | 2014 | |
− | + | | [[EQT PROD CO]] | |
− | |||
− | |||
− | |||
− | |||
− | | 2014 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 12.00 Bbl | | style="text-align: right;" | 12.00 Bbl | ||
Line 435: | Line 471: | ||
| 34-007-24355 | | 34-007-24355 | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 5,215.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 207.00 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-21438 | | 34-155-21438 | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 650.00 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34-007- | + | | 34-007-21847 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 197.00 Bbl | | style="text-align: right;" | 197.00 Bbl | ||
Line 483: | Line 499: | ||
| 34-007-21847 | | 34-007-21847 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 100.00 Bbl | | style="text-align: right;" | 100.00 Bbl | ||
Line 489: | Line 506: | ||
| 34-007-23262 | | 34-007-23262 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Fracing Fluid Waste (in Barrels) |
− | | | + | | style="text-align: right;" | 110.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
+ | | | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 165.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-157-25511 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 5,284.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 244.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34-007- | + | | 34-007-24355 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 202.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34-007- | + | | 34-007-2-3097 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 107.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-059-24202 |
|- | |- | ||
− | | | + | | 2016 |
− | + | | [[EQT PROD CO]] | |
− | | | ||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 834.00 Bbl |
− | | | + | | RESIDUAL WASTE PROCESSING FACILITY |
− | | | + | | WMGR123NW005 |
|- | |- | ||
− | | 2016 | + | | 2016 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 2,566.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 82.00 Bbl | | style="text-align: right;" | 82.00 Bbl | ||
Line 555: | Line 569: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 135.00 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| WMGR123NW011 | | WMGR123NW011 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 60.00 Bbl | | style="text-align: right;" | 60.00 Bbl | ||
Line 579: | Line 583: | ||
| WMGR123NW011 | | WMGR123NW011 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,183.00 Bbl |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NW011 | | WMGR123NW011 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 2,140.00 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 215.00 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 393.43 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 241.32 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | + | | 2018 | |
− | + | | [[EQT PROD CO]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2018 | ||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | + | | style="text-align: right;" | 5.60 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align: right;" | 5. | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NW009 | | WMGR123NW009 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 605.10 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NW011 | | WMGR123NW011 | ||
|- | |- | ||
− | + | | 2019 | |
− | + | | [[EQT PROD CO]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2019 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 5.07 Bbl | | style="text-align: right;" | 5.07 Bbl | ||
Line 783: | Line 639: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 15.99 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
Line 808: | Line 665: | ||
| 1881815 | | 1881815 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2010-04-21 |
| Drilling/Alteration | | Drilling/Alteration | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 815: | Line 672: | ||
| 1885683 | | 1885683 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2010-05-13 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 822: | Line 679: | ||
| 1886690 | | 1886690 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2010-05-18 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 829: | Line 686: | ||
| 1886794 | | 1886794 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2010-05-17 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 836: | Line 693: | ||
| 1888376 | | 1888376 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2010-06-01 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 843: | Line 700: | ||
| 1898201 | | 1898201 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2010-07-14 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 850: | Line 707: | ||
| 1903492 | | 1903492 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2010-07-13 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 857: | Line 714: | ||
| 1910595 | | 1910595 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2010-09-03 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 864: | Line 721: | ||
| 1929885 | | 1929885 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2010-11-23 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 871: | Line 728: | ||
| 1950030 | | 1950030 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2011-02-15 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 878: | Line 735: | ||
| 1965635 | | 1965635 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2011-04-14 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 885: | Line 742: | ||
| 2008686 | | 2008686 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2011-10-05 |
| Complaint Inspection | | Complaint Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 892: | Line 749: | ||
| 2058570 | | 2058570 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2012-04-03 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 899: | Line 756: | ||
| 2074096 | | 2074096 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2012-06-05 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 906: | Line 763: | ||
| 2082764 | | 2082764 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2012-07-12 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 913: | Line 770: | ||
| 2170537 | | 2170537 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2013-05-30 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 920: | Line 777: | ||
| 2432022 | | 2432022 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2015-12-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 927: | Line 784: | ||
| 2434115 | | 2434115 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2015-12-18 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 974: | Line 831: | ||
| 586356 | | 586356 | ||
| 04/21/2010 | | 04/21/2010 | ||
− | | | + | | 2010-04-21 |
| 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | | 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | ||
| Administrative | | Administrative | ||
Line 996: | Line 853: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 05 | + | | 2010-05-28 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 1,004: | Line 861: | ||
| CACP - Consent Assessment of Civil Penalty | | CACP - Consent Assessment of Civil Penalty | ||
| Comply/Closed | | Comply/Closed | ||
− | | 11 | + | | 2010-11-12 |
− | | 11 | + | | 2010-11-12 |
| style="text-align: right;" | $10,800.00 | | style="text-align: right;" | $10,800.00 | ||
| style="text-align: right;" | $10,800.00 | | style="text-align: right;" | $10,800.00 | ||
Line 1,016: | Line 873: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Pennsylvania Wells]] | [[Category:Pennsylvania Wells]] |
Well ID: 37-005-30588 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.677947,"lon":-79.381414,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Plumcreek Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 148277 | |
Farm/Lease Name: EDWIN C ROSBOROUGH 590259 | |
License Status: Active | |
Spud Date: 2010-05-09 | |
Permit Date: 2010-04-05 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.677947 | |
Longitude: -79.381414 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EQT PROD CO | 167,707.00 | 85 | 0.00 | 85 | 0.00 | 0 |
2011 | EQT PROD CO | 799,477.00 | 365 | 0.00 | 181 | 0.00 | 181 |
2012 | EQT PROD CO | 844,145.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 400,706.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 410,236.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 446,378.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 304,657.00 | 331 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 294,869.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 95,296.00 | 207 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 65.00 | 4 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | EQT PROD CO | Produced Fluid (in Barrels) | 200.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2010 | EQT PROD CO | Drilling Fluid Waste (in Barrels) | 7,680.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301353 |
2010 | EQT PROD CO | Drilling Fluid Waste (in Barrels) | 3,610.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2010 | EQT PROD CO | Drilling Fluid Waste (in Barrels) | 0.00 Bbl | IDENTIFY METHOD IN COMMENTS | |
2010 | EQT PROD CO | Produced Fluid (in Barrels) | 210.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2011 | EQT PROD CO | Produced Fluid (in Barrels) | 750.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 907.00 Bbl | INJECTION DISPOSAL WELL | 34-049-23127 |
2011 | EQT PROD CO | Produced Fluid (in Barrels) | 420.00 Bbl | INJECTION DISPOSAL WELL | 34-009-22704 |
2011 | EQT PROD CO | Produced Fluid (in Barrels) | 119.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-167-28466 |
2011 | EQT PROD CO | Produced Fluid (in Barrels) | 200.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301353 |
2011 | EQT PROD CO | Produced Fluid (in Barrels) | 360.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2011 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 1,934.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2011 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 120.00 Bbl | INJECTION DISPOSAL WELL | 34-009-22704 |
2011 | EQT PROD CO | Produced Fluid (in Barrels) | 1,410.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24137 |
2011 | EQT PROD CO | Produced Fluid (in Barrels) | 690.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2011 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 329.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EQT PROD CO | Drilling Fluid Waste (in Barrels) | 467.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24523 |
2011 | EQT PROD CO | Produced Fluid (in Barrels) | 240.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-121-23390 |
2011 | EQT PROD CO | Drilling Fluid Waste (in Barrels) | 200.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095443 |
2011 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 332.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24523 |
2011 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 10,250.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 92.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 525-1 |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 5,496.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24137 |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 299.00 Bbl | INJECTION DISPOSAL WELL | 34-133-22523 |
2012 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 100,344.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 949.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 87.00 Bbl | INJECTION DISPOSAL WELL | 34-151-21198 |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-167-29577 |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 566.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 368.00 Bbl | INJECTION DISPOSAL WELL | 34-121-2-3995 |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 437.00 Bbl | INJECTION DISPOSAL WELL | 34-167-28466 |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 2,597.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid (in Barrels) | 739.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2012 | EQT PROD CO | Drilling Fluid Waste (in Barrels) | 5,164.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid (in Barrels) | 581.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2013 | EQT PROD CO | Produced Fluid (in Barrels) | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2013 | EQT PROD CO | Produced Fluid (in Barrels) | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | EQT PROD CO | Produced Fluid (in Barrels) | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2013 | EQT PROD CO | Produced Fluid (in Barrels) | 5,172.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid (in Barrels) | 12.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2014 | EQT PROD CO | Produced Fluid (in Barrels) | 5,215.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid (in Barrels) | 207.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | EQT PROD CO | Produced Fluid (in Barrels) | 650.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 197.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-007-23262 |
2015 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 165.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 5,284.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 244.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 202.00 Bbl | INJECTION DISPOSAL WELL | 34-007-2-3097 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 107.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 834.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 2,566.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 82.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 135.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | EQT PROD CO | Other Oil & Gas Wastes (in Barrels) RWC 899 | 60.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 1,183.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 2,140.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 215.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 393.43 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 241.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 5.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 605.10 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 5.07 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 15.99 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1881815 | Primary Facility | 2010-04-21 | Drilling/Alteration | Violation(s) Noted | Well has been spud; no drilling notification to Department |
1885683 | Primary Facility | 2010-05-13 | Drilling/Alteration | No Violations Noted | MARCELLUS - drilling-awaiting cement/E&S ok/ID&pit ok |
1886690 | Primary Facility | 2010-05-18 | Drilling/Alteration | No Violations Noted | MARCELLUS - drilling @ 7300ft/E&S ok/ID&pit ok |
1886794 | Primary Facility | 2010-05-17 | Routine/Complete Inspection | No Violations Noted | Drilling was ongoing at the time of the inspection. Drill and frac pits located onsite at the time of the inspection and they had more than the required two feet of lined freeboard. Noted that it was raining at the time of the inspection and that all erosion control BMP¿s appeared to be functioning properly. No accelerated erosion & sedimentation was observed in relation to the access road or well-site at the time of the inspection. Noted that it appeared that significant dirt moving and culvert replacement would have had to have been undertaken to make the existing stream crossing for Fagley Run capable of handling the truck traffic necessary for the development of wells located on the well pad. At this time the Department is requesting that the operator forward documentation outlining what work, if any, was performed by the operator to make this stream crossing adequate for well development. This documentation should be forwarded no later than 06/18/10. |
1888376 | Primary Facility | 2010-06-01 | Routine/Complete Inspection | No Violations Noted | Drill rig was not onsite and drilling was not ongoing. Drill and frac pits located onsite at the time of the inspection and they had more than the required two feet of lined freeboard. Noted that all erosion control BMP¿s appeared to be functioning properly. No accelerated erosion & sedimentation was observed in relation to the access road or well-site at the time of the inspection. |
1898201 | Primary Facility | 2010-07-14 | Routine/Complete Inspection | No Violations Noted | Drill rig onsite and drilling was ongoing for permit 005-30590. Observed no accelerated erosion & sedimentation in relation to the access road or well-site. All erosion controls appeared to be functioning properly. Below grade pits located onsite had more than the required two feet of freeboard. |
1903492 | Primary Facility | 2010-07-13 | Drilling/Alteration | No Violations Noted | drilling @ 6700ft/E&S ok/ID&pit ok |
1910595 | Primary Facility | 2010-09-03 | Routine/Complete Inspection | No Violations Noted | Operator was setting up onsite to begin drilling out the plugs after completion of well stimulation. Observed no accelerated erosion & sedimentation in relation to the access road or well-site. All erosion controls appeared to be functioning properly. Pits located onsite had more than the required two feet of freeboard. |
1929885 | Primary Facility | 2010-11-23 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed at the time of the inspection. Well appeared to be equipped for production at the time of the inspection. Drill and frac pits still located onsite at the time of the inspection. Pits had more than the required two feet of lined freeboard and no evidence was observed to suggest that either of the pits were losing any fluids. No accelerated erosion & sedimentation was observed in relation to the site or access road. |
1950030 | Primary Facility | 2011-02-15 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed at the time of the inspection. Well appeared to be equipped for production. Drill and frac pits still located onsite at the time of the inspection. Pits had more than the required two feet of lined freeboard and no evidence was observed to suggest that either of the pits were losing any fluids. No accelerated erosion & sedimentation was observed in relation to the site or access road. Due to winter weather and truck traffic the access road did require routine maintenance (i.e. re-rocking, ditches, culverts, and turn-outs cleaned). |
1965635 | Primary Facility | 2011-04-14 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed at the time of the inspection. Well appeared to be equipped for production. Drill and frac pits still located onsite at the time of the inspection. Pits had more than the required two feet of lined freeboard and no evidence was observed to suggest that either of the pits were losing any fluids. No accelerated erosion & sedimentation was observed in relation to the site or access road. |
2008686 | Primary Facility | 2011-10-05 | Complaint Inspection | No Violations Noted | Equipped for production; Proper ID |
2058570 | Primary Facility | 2012-04-03 | Routine/Complete Inspection | No Violations Noted | Drilling was completed on 07/23/10, well appared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Both drill pit and a frac impoundment were located onsite. Both had more than the required two feet of lined freeboard. There was no accelerated erosion or sedimentation observsed in relation to the access road or well-site. All erosion controls ahd been implemented as outlined in the E&S plan included with the approved ESCGP. |
2074096 | Primary Facility | 2012-06-05 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site regrading activities were undeerway at the time of the inspection. Frac impoundments had been regraded, and the drill pit was in the process of being regraded. |
2082764 | Primary Facility | 2012-07-12 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Drill pit and frac impoundment areas had been regraded, seeded & mulched. It was noted at the time of the inspection that the sediment trap had been left in place onsite. There was no observed accelerated erosion or sedimetation in relation to the access road or well-site. |
2170537 | Primary Facility | 2013-05-30 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. The site had been stabilized and the vegetative cover met the 70% uniform coverage criteria. It was noted that the sediment trap had not been removed and was still located onsite. Sediment trap appeared to be functioning properly. |
2432022 | Primary Facility | 2015-12-10 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Equipment/tanks/E&S controls and well site look good. |
2434115 | Primary Facility | 2015-12-18 | Routine/Complete Inspection | No Violations Noted | Well appeared ot be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimenation in relation to the site or access road. |
2555188 | Primary Facility | 2017-01-25 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located on site within containment. Both tanks and containment appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2688988 | Primary Facility | 2018-01-31 | Routine/Partial Inspection | No Violations Noted | At time of inspection, well 590259 drilled and appears equipped for production. Well 590589 also drilled and appears equipped for production. |
2788688 | Primary Facility | 2018-10-15 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
2821751 | Primary Facility | 2019-01-03 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production with the annulus open. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1881815 | 586356 | 04/21/2010 | 2010-04-21 | 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
586356 | 257423 | NOV - Notice of Violation | Comply/Closed | 2010-05-28 | |||
586356 | 264200 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2010-11-12 | 2010-11-12 | $10,800.00 | $10,800.00 |
For data sources see[6]