If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-007-20411 | | Well ID: 37-007-20411 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.760239, -80.167086 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 04 | + | | Spud Date: 2014-04-09 |
|- | |- | ||
− | | Permit Date: 11 | + | | Permit Date: 2013-11-12 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2015-04-27 | ||
+ | | 2015-05-01 | ||
+ | | style="text-align: right;" | 5380 | ||
+ | | style="text-align: right;" | 9,541,190.0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="17"| 1 | ||
+ | | rowspan="1"| Hydrochloric Acid (7.5%) | ||
+ | | rowspan="1"| Axiall | ||
+ | | rowspan="1"| Acidizing | ||
+ | | Hydrogen Chloride | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.85088 | ||
+ | | style="text-align: right;" | 797269 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="6"| Unihib G | ||
+ | | rowspan="6"| GeoSafe | ||
+ | | rowspan="6"| Acid Corrosion Inhibitor | ||
+ | | Formaldehyde | ||
+ | | 50-00-0 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000712 | ||
+ | | style="text-align: right;" | 6.674 | ||
+ | |- | ||
+ | | Glycol Ether | ||
+ | | 112-34-5 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.000427388 | ||
+ | | style="text-align: right;" | 400.46 | ||
+ | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00003562 | ||
+ | | style="text-align: right;" | 33.372 | ||
+ | |- | ||
+ | | Thiourea | ||
+ | | 62-56-6 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000712 | ||
+ | | style="text-align: right;" | 6.674 | ||
+ | |- | ||
+ | | Acetophenone | ||
+ | | 98-86-2 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000712 | ||
+ | | style="text-align: right;" | 6.674 | ||
+ | |- | ||
+ | | Ethoxylated Alcohol | ||
+ | | 68002-97-1 | ||
+ | | style="text-align: right;" | 35 | ||
+ | | style="text-align: right;" | 0.00024931 | ||
+ | | style="text-align: right;" | 233.602 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Unislik ST50 | ||
+ | | rowspan="1"| CESI | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Petroleum Distillates, Hydrotreated Light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0228073 | ||
+ | | style="text-align: right;" | 21370.3 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| LEB 10X | ||
+ | | rowspan="1"| Weatherford | ||
+ | | rowspan="1"| Gel Breaker | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.00001391 | ||
+ | | style="text-align: right;" | 13.032 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| EC6116A | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00630769 | ||
+ | | style="text-align: right;" | 5910.26 | ||
+ | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00105128 | ||
+ | | style="text-align: right;" | 985.044 | ||
+ | |- | ||
+ | | Polyethylene Glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.0126154 | ||
+ | | style="text-align: right;" | 11820.5 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Iron Control A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00327034 | ||
+ | | style="text-align: right;" | 3064.28 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand (Proppant) | ||
+ | | rowspan="1"| Sargent | ||
+ | | rowspan="1"| Proppant | ||
+ | | Silica | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 99.9 | ||
+ | | style="text-align: right;" | 11.4057 | ||
+ | | style="text-align: right;" | 10,687,100.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Scale Hib A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00322502 | ||
+ | | style="text-align: right;" | 3021.82 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| WGA-3 | ||
+ | | rowspan="1"| PfP Technology | ||
+ | | rowspan="1"| Water Viscosifier | ||
+ | | Guar Gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00133405 | ||
+ | | style="text-align: right;" | 1250 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| PennEnergy Resources | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 86.3349 | ||
+ | | style="text-align: right;" | 80,895,200.0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 124: | Line 303: | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
+ | !scope="col" | Operator | ||
!scope="col" | Waste Type | !scope="col" | Waste Type | ||
!scope="col" | Quantity | !scope="col" | Quantity | ||
Line 129: | Line 309: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 535.79 Tons |
| LANDFILL | | LANDFILL | ||
| CID # 28726 | | CID # 28726 | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,231.00 Bbl | | style="text-align: right;" | 1,231.00 Bbl | ||
Line 147: | Line 323: | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
|- | |- | ||
− | | 2015- | + | | 2015 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
+ | | Servicing Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 106.00 Bbl | ||
+ | | LANDFILL | ||
+ | | CID # 28726 | ||
+ | |- | ||
+ | | 2015 | ||
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 44.51 Tons | | style="text-align: right;" | 44.51 Tons | ||
Line 153: | Line 337: | ||
| CID # 28726 | | CID # 28726 | ||
|- | |- | ||
− | | | + | | 2016 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 247.98 Bbl |
− | | | + | | CENT WASTE TRT FAC NPDES DISCHARGE |
+ | | EPA ID: 748-163 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 12,701.05 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 200.38 Bbl | | style="text-align: right;" | 200.38 Bbl | ||
Line 171: | Line 358: | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | | style="text-align: right;" | | + | | Synthetic Liner Materials (in Tons) RWC 806 |
− | | | + | | style="text-align: right;" | 23.74 Tons |
− | | | + | | LANDFILL |
+ | | CID # 28726 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,028.57 Bbl | | style="text-align: right;" | 1,028.57 Bbl | ||
Line 183: | Line 372: | ||
| 34-155-22403 | | 34-155-22403 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 465.52 Bbl | | style="text-align: right;" | 465.52 Bbl | ||
Line 195: | Line 379: | ||
| 34-155-23223 | | 34-155-23223 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,008.62 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-155-23196 |
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Waste Water Treatment Sludge (in Tons) RWC 804 | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| style="text-align: right;" | 8.08 Tons | | style="text-align: right;" | 8.08 Tons | ||
Line 213: | Line 393: | ||
| UT2300249 | | UT2300249 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 2,329.98 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 14.30 Bbl | | style="text-align: right;" | 14.30 Bbl | ||
Line 237: | Line 407: | ||
| 34-155-23196 | | 34-155-23196 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 86.00 Bbl | | style="text-align: right;" | 86.00 Bbl | ||
Line 267: | Line 414: | ||
| 34-155-23223 | | 34-155-23223 | ||
|- | |- | ||
− | | | + | | 2018 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,586.10 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | + | | 2018 | |
− | + | | [[PENNENERGY RESOURCES LLC]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2018 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 114.40 Bbl | | style="text-align: right;" | 114.40 Bbl | ||
Line 369: | Line 428: | ||
| 34-155-23196 | | 34-155-23196 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 28.50 Bbl | | style="text-align: right;" | 28.50 Bbl | ||
Line 375: | Line 435: | ||
| 34-155-23223 | | 34-155-23223 | ||
|- | |- | ||
− | | | + | | 2019 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 581.11 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
Line 418: | Line 461: | ||
| 2260619 | | 2260619 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-08 |
| Preoperation Inspection | | Preoperation Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 425: | Line 468: | ||
| 2267273 | | 2267273 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-21 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 432: | Line 475: | ||
| 2274998 | | 2274998 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-16 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 439: | Line 482: | ||
| 2275001 | | 2275001 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2014-05-06 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 446: | Line 489: | ||
| 2275028 | | 2275028 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-23 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 453: | Line 496: | ||
| 2276870 | | 2276870 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2014-05-23 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 460: | Line 503: | ||
| 2276905 | | 2276905 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2014-06-03 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 467: | Line 510: | ||
| 2288967 | | 2288967 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2014-06-12 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 474: | Line 517: | ||
| 2296840 | | 2296840 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2014-07-30 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 481: | Line 524: | ||
| 2297593 | | 2297593 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2014-08-22 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 488: | Line 531: | ||
| 2305438 | | 2305438 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2014-08-28 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 495: | Line 538: | ||
| 2307355 | | 2307355 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2014-09-11 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 502: | Line 545: | ||
| 2350394 | | 2350394 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2015-01-20 |
| Complaint Inspection | | Complaint Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 509: | Line 552: | ||
| 2361480 | | 2361480 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 516: | Line 559: | ||
| 2365872 | | 2365872 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-28 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 523: | Line 566: | ||
| 2369000 | | 2369000 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2015-03-02 |
| Administrative/File Review | | Administrative/File Review | ||
| No Violations Noted | | No Violations Noted | ||
Line 530: | Line 573: | ||
| 2372375 | | 2372375 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-02 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 537: | Line 580: | ||
| 2374343 | | 2374343 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2015-05-26 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 544: | Line 587: | ||
| 2381761 | | 2381761 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2015-06-19 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 551: | Line 594: | ||
| 2383237 | | 2383237 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2015-06-29 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 558: | Line 601: | ||
| 2396486 | | 2396486 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2015-07-23 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 565: | Line 608: | ||
| 2396609 | | 2396609 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2015-08-04 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 572: | Line 615: | ||
| 2436853 | | 2436853 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2015-12-29 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 651: | Line 694: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-007-20411 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.760239,"lon":-80.167086,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Beaver | |
Municipality: New Sewickley Township | |
Operator Name: PENNENERGY RESOURCES LLC | |
Well Pad ID: 150486 | |
Farm/Lease Name: B3 PER B3-1H | |
License Status: Active | |
Spud Date: 2014-04-09 | |
Permit Date: 2013-11-12 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.760239 | |
Longitude: -80.167086 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-04-27 | 2015-05-01 | 5380 | 9,541,190.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid (7.5%) | Axiall | Acidizing | Hydrogen Chloride | 7647-01-0 | 40 | 0.85088 | 797269 |
Unihib G | GeoSafe | Acid Corrosion Inhibitor | Formaldehyde | 50-00-0 | 1 | 0.00000712 | 6.674 | |
Glycol Ether | 112-34-5 | 60 | 0.000427388 | 400.46 | ||||
Methanol | 67-56-1 | 5 | 0.00003562 | 33.372 | ||||
Thiourea | 62-56-6 | 1 | 0.00000712 | 6.674 | ||||
Acetophenone | 98-86-2 | 1 | 0.00000712 | 6.674 | ||||
Ethoxylated Alcohol | 68002-97-1 | 35 | 0.00024931 | 233.602 | ||||
Unislik ST50 | CESI | Friction Reducer | Petroleum Distillates, Hydrotreated Light | 64742-47-8 | 30 | 0.0228073 | 21370.3 | |
LEB 10X | Weatherford | Gel Breaker | Ethylene Glycol | 107-21-1 | 40 | 0.00001391 | 13.032 | |
EC6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00630769 | 5910.26 | |
Dibromoacetonitrile | 3252-43-5 | 5 | 0.00105128 | 985.044 | ||||
Polyethylene Glycol | 25322-68-3 | 60 | 0.0126154 | 11820.5 | ||||
Iron Control A | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00327034 | 3064.28 | |
Sand (Proppant) | Sargent | Proppant | Silica | 14808-60-7 | 99.9 | 11.4057 | 10,687,100.0 | |
Scale Hib A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00322502 | 3021.82 | |
WGA-3 | PfP Technology | Water Viscosifier | Guar Gum | 9000-30-0 | 100 | 0.00133405 | 1250 | |
Water | PennEnergy Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 86.3349 | 80,895,200.0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | PENNENERGY RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | PENNENERGY RESOURCES LLC | 369,205.00 | 87 | 0.00 | 0 | 2,594.00 | 87 |
2016 | PENNENERGY RESOURCES LLC | 1,010,827.00 | 366 | 0.00 | 0 | 3,666.00 | 366 |
2017 | PENNENERGY RESOURCES LLC | 756,149.00 | 342 | 0.00 | 0 | 2,395.00 | 342 |
2018 | PENNENERGY RESOURCES LLC | 675,537.00 | 349 | 0.00 | 0 | 1,604.00 | 349 |
2019 | PENNENERGY RESOURCES LLC | 149,429.00 | 78 | 0.00 | 0 | 347.00 | 78 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | PENNENERGY RESOURCES LLC | Drill Cuttings (in Tons) | 535.79 Tons | LANDFILL | CID # 28726 |
2014 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste (in Barrels) | 1,231.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2015 | PENNENERGY RESOURCES LLC | Servicing Fluid (in Barrels) | 106.00 Bbl | LANDFILL | CID # 28726 |
2015 | PENNENERGY RESOURCES LLC | Fracturing Fluid Waste (in Tons) | 44.51 Tons | LANDFILL | CID # 28726 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 247.98 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 12,701.05 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | PENNENERGY RESOURCES LLC | Other Oil & Gas Wastes (in Barrels) RWC 899 | 200.38 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2016 | PENNENERGY RESOURCES LLC | Synthetic Liner Materials (in Tons) RWC 806 | 23.74 Tons | LANDFILL | CID # 28726 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 1,028.57 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 465.52 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 1,008.62 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2016 | PENNENERGY RESOURCES LLC | Waste Water Treatment Sludge (in Tons) RWC 804 | 8.08 Tons | LANDFILL | UT2300249 |
2017 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 2,329.98 Bbl | REUSE (AT WELL PAD) | |
2017 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 14.30 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 86.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 1,586.10 Bbl | REUSE (AT WELL PAD) | |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 114.40 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 28.50 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 581.11 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2260619 | Primary Facility | 2014-04-08 | Preoperation Inspection | No Violations Noted | This preoperational inspection satisfies operator's obligation as outlined under Title 58 , Ch 32 § 3258 a. 1. |
2267273 | Primary Facility | 2014-04-21 | Routine/Complete Inspection | No Violations Noted | The conductor was set for this well targeting the either the Genesee or the Marcellus layer. The inspection for this well was conducted concurrently with the inspection for site number 776908 (inspection report # 2267205) . The water impoundment was under construction at time of inspection. All E&S controls appeared to be installed according to plan and sufficient to prevent off-site transfer of sediment. No erosion or sedimentation issues were noted. |
2274998 | Primary Facility | 2014-04-16 | Drilling/Alteration | No Violations Noted | THE CONDUCTOR IS IN. A SOUND WALL IS BEING BUILT. |
2275001 | Primary Facility | 2014-05-06 | Drilling/Alteration | No Violations Noted | HIGHLANDS 7 COMPLETED TOP HOLE AT 2,003'. THE SITE IS OK. |
2275028 | Primary Facility | 2014-04-23 | Drilling/Alteration | No Violations Noted | HIGHLANDS 7 SET UP AND READY TO DRILL TOP HOLE. THE SITE IS OK. |
2276870 | Primary Facility | 2014-05-23 | Drilling/Alteration | No Violations Noted | TOP HOLE COMPLETE. THE RIG HAS MOVED. |
2276905 | Primary Facility | 2014-06-03 | Drilling/Alteration | No Violations Noted | TOP HOLE COMPLETE. ALL EQUIPTMENT REMOVED. PROTECTIVE COVER IS STILL ON THE PAD. |
2288967 | Primary Facility | 2014-06-12 | Routine/Complete Inspection | No Violations Noted | The tophole was drilled for this well targeting the Genesee layer. The inspection for this well was conducted concurrently with the inspection for site number 776908. The water impoundment was constructed but not lined at time of inspection. All E&S controls appeared to be installed according to plan and sufficient to prevent off-site transfer of sediment. A moderate slip was noted on the topsoil pile but adequate vegetative growth and E&S controls appeared to prevent off-site transport of sediment. |
2296840 | Primary Facility | 2014-07-30 | Drilling/Alteration | No Violations Noted | TOP HOLE IS COMPLETE. THERE IS NO NEW RIG YET. THERE IS NO ACTIVITY TODAY. |
2297593 | Primary Facility | 2014-08-22 | Routine/Complete Inspection | No Violations Noted | This well targets the Genesee layer. The inspection for this well was conducted concurrently with the inspection for site number 776908. Well was properly labeled. Topsoil pile had adequate vegetative growth. E&S controls were sufficient to prevent off-site transport of sediment. Damp area was noted at corner of containment. Department requests operator ensure containment is adequate to contain residual waste. |
2305438 | Primary Facility | 2014-08-28 | Drilling/Alteration | No Violations Noted | PATTERSON 259 JUST STARTING TO DRILL THE BOTTOM HOLE. THE SITE IS OK. |
2307355 | Primary Facility | 2014-09-11 | Drilling/Alteration | No Violations Noted | PATTERSON 259 COMPLETED DRILLING AT 10,469'. THE RIG HAS MOVED. |
2350394 | Primary Facility | 2015-01-20 | Complaint Inspection | No Violations Noted | |
2361480 | Primary Facility | 2015-04-10 | Routine/Complete Inspection | No Violations Noted | |
2365872 | Primary Facility | 2015-04-28 | Routine/Complete Inspection | No Violations Noted | |
2369000 | Primary Facility | 2015-03-02 | Administrative/File Review | No Violations Noted | |
2372375 | Primary Facility | 2015-04-02 | Drilling/Alteration | No Violations Noted | THIS WELL HAS BEEN PRESSURE TESTED BUT NOT FRACED. |
2374343 | Primary Facility | 2015-05-26 | Routine/Complete Inspection | No Violations Noted | |
2381761 | Primary Facility | 2015-06-19 | Routine/Complete Inspection | No Violations Noted | |
2383237 | Primary Facility | 2015-06-29 | Drilling/Alteration | No Violations Noted | THIS WELL IS FRACED AND SHUT-IN. |
2396486 | Primary Facility | 2015-07-23 | Drilling/Alteration | No Violations Noted | THE PAD HAS A PROTECTIVE COVER. FLOWBACK HAS STARTED. |
2396609 | Primary Facility | 2015-08-04 | Drilling/Alteration | No Violations Noted | FLOWBACK HAS BEEN COMPLETED IN THIS WELL. |
2436853 | Primary Facility | 2015-12-29 | Routine/Complete Inspection | No Violations Noted | |
2449892 | Primary Facility | 2016-01-20 | Routine/Complete Inspection | No Violations Noted | THIS WELL IS DRILLED, FRACED, AND PRODUCING.
THE SITE AND EQUIPTMENT ARE IN GOOD CONDITION. |
2481818 | Primary Facility | 2016-04-26 | Routine/Complete Inspection | No Violations Noted | THIS WELL HAS BEEN COMPLETED AND IS NOW PRODUCING.
THE SITE IS IN GOOD CONDITION. |
2561311 | Primary Facility | 2017-02-14 | Routine/Complete Inspection | No Violations Noted | On 2/14/2017, WQS Brian MacQuarrie onsite at unconventional well site. Act 9 sign installed and maintained. Freshwater impoundment installed and fenced in. Four wells in production. Two four hundred bbl tanks installed and maintained within secondary steel containment structure. Erosion and Sedimentation Best Management practices installed and maintained. Site stabilized in previously disturbed areas around pad and access road with vegetative growth. No apparent E/S issues. |
2665296 | Primary Facility | 2017-11-29 | Routine/Complete Inspection | No Violations Noted | Site had been constructed as outlined in the E&S plan contained within the ESCGP. All site and access road erosion controls had been implemented and properly maintained. There was no observed accelerated erosion or sedimentation in relation to the site or access road. All disturbed areas had been stabilized with vegetation attaining 70% uniform vegetative cover. Well appeared to be equipped for production. Two produced fluid tanks were located onsite within secondary containment. Both the tanks and containment appeared to be in sound condition. Freshwater impoundment located onsite and it contained what appeared to be freshwater. |
2686191 | Primary Facility | 2018-01-12 | Routine/Complete Inspection | No Violations Noted | Site had been constructed as outlined within the E&S Plan contained within the ESCGP. All erosion controls had been implemented and maintained properly. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Well appeared to be equipped for production. Two brine tanks located onsite within secondary containment. Both the tanks and containment appeared to be in sound condition. Well development impoundment located onsite and it contained fluids. |
2856221 | Primary Facility | 2019-03-20 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well equipped for production. Two brine tanks within secondary containment and appears structurally sound. GPUs within secondary containment. No E&S issues. |
For data sources see[7]