X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-019-21955"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-019-21955
 
| Well ID: 37-019-21955
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.771175, -80.103536 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.771175, -80.103536 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 06/18/2012
+
| Spud Date: 2012-06-18
 
|-
 
|-
| Permit Date: 5/18/2012
+
| Permit Date: 2012-05-18
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2013-02-04
 +
| 2013-02-04
 +
| style="text-align: right;" | 5505.0
 +
| style="text-align: right;" | 4300086.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="22"| 1
 +
| rowspan="1"| Sand (Proppant)
 +
| rowspan="1"| Vertex
 +
| rowspan="1"| Proppant
 +
| Silica Sand
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 10.24128
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| CS-500 SI
 +
| rowspan="1"| ICI
 +
| rowspan="1"| Scale Inhibitor
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00476
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FE-100L
 +
| rowspan="1"| ICI
 +
| rowspan="1"| Iron Control
 +
| Citric Acid
 +
| 77-92-9
 +
| style="text-align: right;" | 55.0
 +
| style="text-align: right;" | 0.00271
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Acid (Hydrochloric)
 +
| rowspan="1"| FTS
 +
| rowspan="1"| Acidizing
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 7.5
 +
| style="text-align: right;" | 0.11231
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FRW-200W
 +
| rowspan="1"| ICI
 +
| rowspan="1"| Friction Reducer
 +
| Petroleum Distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.01743
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| CI-150L
 +
| rowspan="1"| ICI
 +
| rowspan="1"| Corrosion Inhibitor
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00076
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| ICI-3240
 +
| rowspan="1"| ICI
 +
| rowspan="1"| Bacteriacide
 +
| Dazomet
 +
| 533-74-4
 +
| style="text-align: right;" | 24.0
 +
| style="text-align: right;" | 0.01173
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| HVG-1
 +
| rowspan="1"| FTS
 +
| rowspan="1"| Gel
 +
| Guar Gum
 +
| 9000-30-0
 +
| style="text-align: right;" | 45.0
 +
| style="text-align: right;" | 0.00101
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Rex
 +
| rowspan="1"| Base Fluid
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 88.09552
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| APB-1
 +
| rowspan="1"| FTS
 +
| rowspan="1"| Breaker
 +
| Ammonium Persulfate
 +
| 7727-54-0
 +
| style="text-align: right;" | 95.0
 +
| style="text-align: right;" | 0.00004000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| NE-100L
 +
| rowspan="1"| ICI
 +
| rowspan="1"| Non-Emulsifier
 +
| 2-Butoxyethenol
 +
| 111-76-2
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00014
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="11"|
 +
| rowspan="11"|
 +
| rowspan="11"|
 +
| Organic Amine Resin Salt
 +
| Proprietary
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00025
 +
| style="text-align: right;" |
 +
|-
 +
| Dimethylformamide
 +
| 68-12-2
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00025
 +
| style="text-align: right;" |
 +
|-
 +
| Quaternary Ammonium Compound
 +
| Proprietary
 +
| style="text-align: right;" | 5.0
 +
| style="text-align: right;" | 0.00013
 +
| style="text-align: right;" |
 +
|-
 +
| 2-Propanol
 +
| 67-63-0
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00014
 +
| style="text-align: right;" |
 +
|-
 +
| Clay
 +
| 14808-60-7
 +
| style="text-align: right;" | 2.5
 +
| style="text-align: right;" | 0.00006000
 +
| style="text-align: right;" |
 +
|-
 +
| Dodecylbenzenesulfonic Acid
 +
| 27176-87-0
 +
| style="text-align: right;" | 5.0
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" |
 +
|-
 +
| Surfactant
 +
| 68439-51-0
 +
| style="text-align: right;" | 2.5
 +
| style="text-align: right;" | 0.00006000
 +
| style="text-align: right;" |
 +
|-
 +
| Sodium Hydroxide
 +
| 1310-73-2
 +
| style="text-align: right;" | 4.0
 +
| style="text-align: right;" | 0.00195
 +
| style="text-align: right;" |
 +
|-
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 4.0
 +
| style="text-align: right;" | 0.00232
 +
| style="text-align: right;" |
 +
|-
 +
| Petroleum Distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 50.0
 +
| style="text-align: right;" | 0.00112
 +
| style="text-align: right;" |
 +
|-
 +
| Aromatic Aldehyde
 +
| Proprietary
 +
| style="text-align: right;" | 5.0
 +
| style="text-align: right;" | 0.00013
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 61: Line 278:
 
|-
 
|-
 
| 2012
 
| 2012
| [[REX ENERGY OPERATING CORP]]
+
| [[RE GAS DEV LLC]]
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
Line 115: Line 332:
 
|-
 
|-
 
| 2018
 
| 2018
| [[RE GAS DEV LLC]]
+
| [[PENNENERGY RESOURCES LLC]]
 
| style="text-align: right;" | 278,297.48
 
| style="text-align: right;" | 278,297.48
 
| style="text-align: right;" | 362
 
| style="text-align: right;" | 362
Line 142: Line 359:
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Period
 
!scope="col" | Period
 +
!scope="col" | Operator
 
!scope="col" | Waste Type
 
!scope="col" | Waste Type
 
!scope="col" | Quantity
 
!scope="col" | Quantity
Line 147: Line 365:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 15FEBU
+
| 2012
| Produced Fluid (in Barrels)
+
| [[RE GAS DEV LLC]]
| style="text-align: right;" | 51.77 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| 3192
 
|-
 
| 15JANU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 55.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| 3192
 
|-
 
| 15JUNU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 60.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| 3192
 
|-
 
| 15MARU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 193.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| 3192
 
|-
 
| 15MARU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 55.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-155-24076
 
|-
 
| 15MAYU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 105.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-007-21847
 
|-
 
| 15NOVU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 110.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-151-21179
 
|-
 
| 16AUGU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-007-21847
 
|-
 
| 16DECU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JANU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-007-21847
 
|-
 
| 16JULU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 42.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-007-21847
 
|-
 
| 16JUNU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 41.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-133-24462
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16SEPU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-007-21847
 
|-
 
| 2012-2
 
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 1,283.73 Tons
 
| style="text-align: right;" | 1,283.73 Tons
Line 237: Line 372:
 
| 100585
 
| 100585
 
|-
 
|-
| 2013-1
+
| 2013
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 315.00 Bbl
+
| style="text-align: right;" | 1,333.20 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| EPA ID: 748-163
+
| 34-151-21179
 
|-
 
|-
| 2013-1
+
| 2013
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 945.00 Bbl
+
| style="text-align: right;" | 105.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-007-24523
+
| 34-013-20609
 
|-
 
|-
| 2013-1
+
| 2013
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 630.00 Bbl
 
| style="text-align: right;" | 630.00 Bbl
Line 255: Line 393:
 
| 34-031-27177
 
| 34-031-27177
 
|-
 
|-
| 2013-1
+
| 2013
| Produced Fluid (in Barrels)
+
| [[RE GAS DEV LLC]]
| style="text-align: right;" | 525.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-083-24137
 
|-
 
| 2013-1
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,260.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-151-21179
 
|-
 
| 2013-1
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 773.36 Bbl
+
| style="text-align: right;" | 1,489.36 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-21438
 
| 34-155-21438
 
|-
 
|-
| 2013-1
+
| 2013
| Produced Fluid (in Barrels)
+
| [[RE GAS DEV LLC]]
| style="text-align: right;" | 210.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-155-21447
 
|-
 
| 2013-2
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 210.00 Bbl
 
| style="text-align: right;" | 210.00 Bbl
Line 285: Line 407:
 
| 3192
 
| 3192
 
|-
 
|-
| 2013-2
+
| 2013
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 140.00 Bbl
+
| style="text-align: right;" | 420.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-007-24523
+
| 34-155-21447
 
|-
 
|-
| 2013-2
+
| 2013
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 105.00 Bbl
+
| style="text-align: right;" | 1,085.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-013-20609
+
| 34-007-24523
 
|-
 
|-
| 2013-2
+
| 2013
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 73.20 Bbl
+
| style="text-align: right;" | 525.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-151-21179
+
| 34-083-24137
 
|-
 
|-
| 2013-2
+
| 2013
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 716.00 Bbl
+
| style="text-align: right;" | 315.00 Bbl
| INJECTION DISPOSAL WELL
 
| 34-155-21438
 
|-
 
| 2013-2
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 210.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-155-21447
 
|-
 
| 2014-1
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 105.00 Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| 3192
+
| EPA ID: 748-163
 
|-
 
|-
| 2014-1
+
| 2014
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 315.00 Bbl
+
| style="text-align: right;" | 494.55 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-151-21179
 
| 34-151-21179
 
|-
 
|-
| 2014-1
+
| 2014
| Produced Fluid (in Barrels)
+
| [[RE GAS DEV LLC]]
| style="text-align: right;" | 210.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-155-21438
 
|-
 
| 2014-1
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 105.00 Bbl
 
| style="text-align: right;" | 105.00 Bbl
Line 339: Line 449:
 
| 34-155-21447
 
| 34-155-21447
 
|-
 
|-
| 2014-1
+
| 2014
| Produced Fluid (in Barrels)
+
| [[RE GAS DEV LLC]]
| style="text-align: right;" | 105.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-155-23223
 
|-
 
| 2014-2
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 158.44 Bbl
 
| style="text-align: right;" | 158.44 Bbl
Line 351: Line 456:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2014-2
+
| 2014
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 179.55 Bbl
+
| style="text-align: right;" | 105.00 Bbl
| INJECTION DISPOSAL WELL
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| 34-151-21179
+
| 3192
 
|-
 
|-
| 2014-2
+
| 2014
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 420.00 Bbl
 
| style="text-align: right;" | 420.00 Bbl
Line 363: Line 470:
 
| 34-155-24076
 
| 34-155-24076
 
|-
 
|-
| 2015-01
+
| 2014
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 55.00 Bbl
+
| style="text-align: right;" | 105.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| 3192
+
| 34-155-23223
 
|-
 
|-
| 2015-02
+
| 2014
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 51.77 Bbl
+
| style="text-align: right;" | 210.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| 3192
+
| 34-155-21438
 
|-
 
|-
| 2015-03
+
| 2015
| Produced Fluid (in Barrels)
+
|  
| style="text-align: right;" | 193.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| 3192
 
|-
 
| 2015-03
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 387: Line 491:
 
| 34-155-24076
 
| 34-155-24076
 
|-
 
|-
| 2015-05
+
| 2015
 +
|
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 359.77 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| 3192
 +
|-
 +
| 2015
 +
|
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 105.00 Bbl
 
| style="text-align: right;" | 105.00 Bbl
Line 393: Line 505:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2015-06
+
| 2015
| Produced Fluid (in Barrels)
+
|  
| style="text-align: right;" | 60.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| 3192
 
|-
 
| 2015-11
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 110.00 Bbl
 
| style="text-align: right;" | 110.00 Bbl
Line 405: Line 512:
 
| 34-151-21179
 
| 34-151-21179
 
|-
 
|-
| 2016-01
+
| 2016
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 50.00 Bbl
+
| style="text-align: right;" | 180.00 Bbl
| INJECTION DISPOSAL WELL
+
| REUSE OTHER THAN ROAD SPREADING
| 34-007-21847
+
|  
 
|-
 
|-
| 2016-06
+
| 2016
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 41.00 Bbl
 
| style="text-align: right;" | 41.00 Bbl
Line 417: Line 526:
 
| 34-133-24462
 
| 34-133-24462
 
|-
 
|-
| 2016-07
+
| 2016
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 42.00 Bbl
+
| style="text-align: right;" | 282.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2016-08
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[RE GAS DEV LLC]]
| style="text-align: right;" | 100.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-007-21847
 
|-
 
| 2016-09
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-007-21847
 
|-
 
| 2016-10
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2016-12
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2017-01
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 100.00 Bbl
+
| style="text-align: right;" | 460.00 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
| 2017-02
+
| 2017
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
Line 459: Line 547:
 
| WMGR123SW019
 
| WMGR123SW019
 
|-
 
|-
| 2017-03
+
| 2017
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 90.00 Bbl
+
| style="text-align: right;" | 370.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-099-23158
 
| 34-099-23158
 
|-
 
|-
| 2017-04
+
| 2018
| Produced Fluid (in Barrels) RWC 802
+
| [[RE GAS DEV LLC]]
| style="text-align: right;" | 90.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-099-23158
 
|-
 
| 2017-05
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-099-23158
 
|-
 
| 2017-07
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-099-23158
+
| 34-155-24079
 
|-
 
|-
| 2017-08
+
| 2018
 +
| [[PENNENERGY RESOURCES LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 90.00 Bbl
+
| style="text-align: right;" | 190.00 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
| 2017-09
+
| 2018
 +
| [[RE GAS DEV LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 90.00 Bbl
+
| style="text-align: right;" | 270.00 Bbl
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-10
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-12
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-02
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-099-23158
 
| 34-099-23158
 
|-
 
|-
| 2018-03
+
| 2019
| Produced Fluid (in Barrels) RWC 802
+
| [[PENNENERGY RESOURCES LLC]]
| style="text-align: right;" | 90.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-099-23158
 
|-
 
| 2018-06
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-099-23158
 
|-
 
| 2018-07
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-09
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 100.00 Bbl
+
| style="text-align: right;" | 200.00 Bbl
| INJECTION DISPOSAL WELL
 
| 34-155-24079
 
|-
 
| 2018-11
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2019-01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2019-03
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
Line 574: Line 601:
 
| 2081557
 
| 2081557
 
| Primary Facility
 
| Primary Facility
| 07/03/2012
+
| 2012-07-03
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 581: Line 608:
 
| 2083575
 
| 2083575
 
| Primary Facility
 
| Primary Facility
| 07/17/2012
+
| 2012-07-17
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 588: Line 615:
 
| 2085628
 
| 2085628
 
| Primary Facility
 
| Primary Facility
| 07/24/2012
+
| 2012-07-24
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 595: Line 622:
 
| 2093038
 
| 2093038
 
| Primary Facility
 
| Primary Facility
| 08/17/2012
+
| 2012-08-17
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 602: Line 629:
 
| 2100765
 
| 2100765
 
| Primary Facility
 
| Primary Facility
| 09/17/2012
+
| 2012-09-17
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 609: Line 636:
 
| 2161727
 
| 2161727
 
| Primary Facility
 
| Primary Facility
| 04/25/2013
+
| 2013-04-25
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 616: Line 643:
 
| 2199008
 
| 2199008
 
| Primary Facility
 
| Primary Facility
| 08/26/2013
+
| 2013-08-26
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 623: Line 650:
 
| 2291476
 
| 2291476
 
| Primary Facility
 
| Primary Facility
| 07/15/2014
+
| 2014-07-15
 
| Site Restoration
 
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
Line 665: Line 692:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 02/04/2013
 
| 02/04/2013
 
| style="text-align: right;" | 5505.0
 
| style="text-align: right;" | 4300086.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="22"| 1
 
| rowspan="1"| Sand (Proppant)
 
| rowspan="1"| Vertex
 
| rowspan="1"| Proppant
 
| Silica Sand
 
| 14808-60-7
 
| style="text-align: right;" | 100.0
 
| style="text-align: right;" | 10.24128
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| CS-500 SI
 
| rowspan="1"| ICI
 
| rowspan="1"| Scale Inhibitor
 
| Ethylene Glycol
 
| 107-21-1
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00476
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| FE-100L
 
| rowspan="1"| ICI
 
| rowspan="1"| Iron Control
 
| Citric Acid
 
| 77-92-9
 
| style="text-align: right;" | 55.0
 
| style="text-align: right;" | 0.00271
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Acid (Hydrochloric)
 
| rowspan="1"| FTS
 
| rowspan="1"| Acidizing
 
| Hydrochloric Acid
 
| 7647-01-0
 
| style="text-align: right;" | 7.5
 
| style="text-align: right;" | 0.11231
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| FRW-200W
 
| rowspan="1"| ICI
 
| rowspan="1"| Friction Reducer
 
| Petroleum Distillate
 
| 64742-47-8
 
| style="text-align: right;" | 30.0
 
| style="text-align: right;" | 0.01743
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| CI-150L
 
| rowspan="1"| ICI
 
| rowspan="1"| Corrosion Inhibitor
 
| Isopropanol
 
| 67-63-0
 
| style="text-align: right;" | 30.0
 
| style="text-align: right;" | 0.00076
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| ICI-3240
 
| rowspan="1"| ICI
 
| rowspan="1"| Bacteriacide
 
| Dazomet
 
| 533-74-4
 
| style="text-align: right;" | 24.0
 
| style="text-align: right;" | 0.01173
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| HVG-1
 
| rowspan="1"| FTS
 
| rowspan="1"| Gel
 
| Guar Gum
 
| 9000-30-0
 
| style="text-align: right;" | 45.0
 
| style="text-align: right;" | 0.00101
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Water
 
| rowspan="1"| Rex
 
| rowspan="1"| Base Fluid
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 100.0
 
| style="text-align: right;" | 88.09552
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| APB-1
 
| rowspan="1"| FTS
 
| rowspan="1"| Breaker
 
| Ammonium Persulfate
 
| 7727-54-0
 
| style="text-align: right;" | 95.0
 
| style="text-align: right;" | 0.00004000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| NE-100L
 
| rowspan="1"| ICI
 
| rowspan="1"| Non-Emulsifier
 
| 2-Butoxyethenol
 
| 111-76-2
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00014
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="11"|
 
| rowspan="11"|
 
| rowspan="11"|
 
| Organic Amine Resin Salt
 
| Proprietary
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00025
 
| style="text-align: right;" |
 
|-
 
| Dimethylformamide
 
| 68-12-2
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00025
 
| style="text-align: right;" |
 
|-
 
| Quaternary Ammonium Compound
 
| Proprietary
 
| style="text-align: right;" | 5.0
 
| style="text-align: right;" | 0.00013
 
| style="text-align: right;" |
 
|-
 
| 2-Propanol
 
| 67-63-0
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00014
 
| style="text-align: right;" |
 
|-
 
| Clay
 
| 14808-60-7
 
| style="text-align: right;" | 2.5
 
| style="text-align: right;" | 0.00006000
 
| style="text-align: right;" |
 
|-
 
| Dodecylbenzenesulfonic Acid
 
| 27176-87-0
 
| style="text-align: right;" | 5.0
 
| style="text-align: right;" | 0.00007000
 
| style="text-align: right;" |
 
|-
 
| Surfactant
 
| 68439-51-0
 
| style="text-align: right;" | 2.5
 
| style="text-align: right;" | 0.00006000
 
| style="text-align: right;" |
 
|-
 
| Sodium Hydroxide
 
| 1310-73-2
 
| style="text-align: right;" | 4.0
 
| style="text-align: right;" | 0.00195
 
| style="text-align: right;" |
 
|-
 
| Ethylene Glycol
 
| 107-21-1
 
| style="text-align: right;" | 4.0
 
| style="text-align: right;" | 0.00232
 
| style="text-align: right;" |
 
|-
 
| Petroleum Distillate
 
| 64742-47-8
 
| style="text-align: right;" | 50.0
 
| style="text-align: right;" | 0.00112
 
| style="text-align: right;" |
 
|-
 
| Aromatic Aldehyde
 
| Proprietary
 
| style="text-align: right;" | 5.0
 
| style="text-align: right;" | 0.00013
 
| style="text-align: right;" |
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 20:54, 20 August 2019

Well Details

Well ID: 37-019-21955
Loading map...
Country: United States
State: Pennsylvania
County: Butler
Municipality: Jackson Township
Operator Name: PENNENERGY RESOURCES LLC
Well Pad ID: 147848
Farm/Lease Name: BREAKNECK BEAGLE CLUB UNIT 2H
License Status: Active
Spud Date: 2012-06-18
Permit Date: 2012-05-18
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.771175
Longitude: -80.103536

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-02-04 2013-02-04 5505.0 4300086.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Vertex Proppant Silica Sand 14808-60-7 100.0 10.24128
CS-500 SI ICI Scale Inhibitor Ethylene Glycol 107-21-1 10.0 0.00476
FE-100L ICI Iron Control Citric Acid 77-92-9 55.0 0.00271
Acid (Hydrochloric) FTS Acidizing Hydrochloric Acid 7647-01-0 7.5 0.11231
FRW-200W ICI Friction Reducer Petroleum Distillate 64742-47-8 30.0 0.01743
CI-150L ICI Corrosion Inhibitor Isopropanol 67-63-0 30.0 0.00076
ICI-3240 ICI Bacteriacide Dazomet 533-74-4 24.0 0.01173
HVG-1 FTS Gel Guar Gum 9000-30-0 45.0 0.00101
Water Rex Base Fluid Water 7732-18-5 100.0 88.09552
APB-1 FTS Breaker Ammonium Persulfate 7727-54-0 95.0 0.00004000
NE-100L ICI Non-Emulsifier 2-Butoxyethenol 111-76-2 10.0 0.00014
Organic Amine Resin Salt Proprietary 10.0 0.00025
Dimethylformamide 68-12-2 10.0 0.00025
Quaternary Ammonium Compound Proprietary 5.0 0.00013
2-Propanol 67-63-0 10.0 0.00014
Clay 14808-60-7 2.5 0.00006000
Dodecylbenzenesulfonic Acid 27176-87-0 5.0 0.00007000
Surfactant 68439-51-0 2.5 0.00006000
Sodium Hydroxide 1310-73-2 4.0 0.00195
Ethylene Glycol 107-21-1 4.0 0.00232
Petroleum Distillate 64742-47-8 50.0 0.00112
Aromatic Aldehyde Proprietary 5.0 0.00013

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 RE GAS DEV LLC 0.00 0 0.00 0 0.00 0
2013 RE GAS DEV LLC 591,216.63 299 0.00 0 1,024.21 299
2014 RE GAS DEV LLC 544,748.58 365 437.28 184 721.26 181
2015 RE GAS DEV LLC 470,084.58 356 0.00 0 557.61 356
2016 RE GAS DEV LLC 379,217.51 356 0.00 0 306.41 356
2017 RE GAS DEV LLC 320,211.27 356 0.00 0 126.00 356
2018 PENNENERGY RESOURCES LLC 278,297.48 362 0.00 0 55.84 179
2019 PENNENERGY RESOURCES LLC 65,963.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 RE GAS DEV LLC Drill Cuttings (in Tons) 1,283.73 Tons LANDFILL 100585
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 1,333.20 Bbl INJECTION DISPOSAL WELL 34-151-21179
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 105.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 630.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 1,489.36 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 210.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 3192
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 420.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 1,085.00 Bbl INJECTION DISPOSAL WELL 34-007-24523
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 525.00 Bbl INJECTION DISPOSAL WELL 34-083-24137
2013 RE GAS DEV LLC Produced Fluid (in Barrels) 315.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2014 RE GAS DEV LLC Produced Fluid (in Barrels) 494.55 Bbl INJECTION DISPOSAL WELL 34-151-21179
2014 RE GAS DEV LLC Produced Fluid (in Barrels) 105.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2014 RE GAS DEV LLC Produced Fluid (in Barrels) 158.44 Bbl INJECTION DISPOSAL WELL 34-007-21847
2014 RE GAS DEV LLC Produced Fluid (in Barrels) 105.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 3192
2014 RE GAS DEV LLC Produced Fluid (in Barrels) 420.00 Bbl INJECTION DISPOSAL WELL 34-155-24076
2014 RE GAS DEV LLC Produced Fluid (in Barrels) 105.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2014 RE GAS DEV LLC Produced Fluid (in Barrels) 210.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015 Produced Fluid (in Barrels) 55.00 Bbl INJECTION DISPOSAL WELL 34-155-24076
2015 Produced Fluid (in Barrels) 359.77 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 3192
2015 Produced Fluid (in Barrels) 105.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 Produced Fluid (in Barrels) 110.00 Bbl INJECTION DISPOSAL WELL 34-151-21179
2016 RE GAS DEV LLC Produced Fluid (in Barrels) RWC 802 180.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 RE GAS DEV LLC Produced Fluid (in Barrels) RWC 802 41.00 Bbl INJECTION DISPOSAL WELL 34-133-24462
2016 RE GAS DEV LLC Produced Fluid (in Barrels) RWC 802 282.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2017 RE GAS DEV LLC Produced Fluid (in Barrels) RWC 802 460.00 Bbl REUSE (AT WELL PAD)
2017 RE GAS DEV LLC Produced Fluid (in Barrels) RWC 802 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 RE GAS DEV LLC Produced Fluid (in Barrels) RWC 802 370.00 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018 RE GAS DEV LLC Produced Fluid (in Barrels) RWC 802 100.00 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 PENNENERGY RESOURCES LLC Produced Fluid (in Barrels) RWC 802 190.00 Bbl REUSE (AT WELL PAD)
2018 RE GAS DEV LLC Produced Fluid (in Barrels) RWC 802 270.00 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 PENNENERGY RESOURCES LLC Produced Fluid (in Barrels) RWC 802 200.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2081557 Primary Facility 2012-07-03 Routine/Partial Inspection No Violations Noted
2083575 Primary Facility 2012-07-17 Drilling/Alteration No Violations Noted
2085628 Primary Facility 2012-07-24 Drilling/Alteration No Violations Noted
2093038 Primary Facility 2012-08-17 Routine/Partial Inspection No Violations Noted
2100765 Primary Facility 2012-09-17 Routine/Partial Inspection No Violations Noted
2161727 Primary Facility 2013-04-25 Routine/Partial Inspection No Violations Noted
2199008 Primary Facility 2013-08-26 Routine/Partial Inspection No Violations Noted
2291476 Primary Facility 2014-07-15 Site Restoration No Violations Noted
2683238 Primary Facility 2018-01-17 Routine/Complete Inspection No Violations Noted On 1/17/2018, WQS Brian MacQuarrie onsite. Site sign posted at entrance. Well pad fenced in and locked. Well pad consists of four wells in production, properly tagged. Twelve 300 bbl (eight produced water and four condensate) installed within stainless steel secondary containment structure. Snow on ground. No apparent issues.

For data sources see[7]

References