X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-063-36844"

m
m
Line 86: Line 86:
 
|-
 
|-
 
| 2010
 
| 2010
| [[DE LTD FAMILY PARTNERSHIP]]
+
| [[TRUE OIL LLC]]
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
Line 185: Line 185:
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Period
 
!scope="col" | Period
 +
!scope="col" | Operator
 
!scope="col" | Waste Type
 
!scope="col" | Waste Type
 
!scope="col" | Quantity
 
!scope="col" | Quantity
Line 190: Line 191:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2010-S02
+
| 2010
 +
| [[TRUE OIL LLC]]
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 170.00 Bbl
 
| style="text-align: right;" | 170.00 Bbl
Line 196: Line 198:
 
| PA0095443
 
| PA0095443
 
|-
 
|-
| 2011-S01
+
| 2011
 +
| [[TRUE OIL LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 639.00 Bbl
+
| style="text-align: right;" | 1,069.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0101508
 
| PA0101508
 
|-
 
|-
| 2011-S02
+
| 2012
| Produced Fluid (in Barrels)
+
| [[TRUE OIL LLC]]
| style="text-align: right;" | 430.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0101508
 
|-
 
| 2012-S01
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 118.00 Bbl
 
| style="text-align: right;" | 118.00 Bbl

Revision as of 22:04, 20 August 2019

Well Details

Well ID: 37-063-36844
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: West Mahoning Township
Operator Name: TRUE OIL LLC
Well Pad ID: 146931
Farm/Lease Name: SWEET M-1
License Status: Active
Spud Date: 2010-07-01
Permit Date: 2010-06-10
Unconventional Well: Y
Configuration: Vertical Well
Latitude: 40.884889
Longitude: -79.183550

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 TRUE OIL LLC 0.00 0 0.00 0 0.00 0
2011 TRUE OIL LLC 7,031.00 169 0.00 0 0.00 0
2012 TRUE OIL LLC 5,873.00 262 0.00 0 0.00 0
2013 TRUE OIL LLC 4,121.00 225 0.00 0 0.00 0
2014 TRUE OIL LLC 1,598.00 121 0.00 0 0.00 0
2015 TRUE OIL LLC 2,253.00 117 0.00 0 0.00 0
2016 TRUE OIL LLC 1,943.00 127 0.00 0 0.00 0
2017 TRUE OIL LLC 1,908.00 195 0.00 0 0.00 0
2018 TRUE OIL LLC 1,211.00 260 0.00 0 0.00 0
2019 TRUE OIL LLC 326.00 72 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 TRUE OIL LLC Drilling Fluid Waste (in Barrels) 170.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 TRUE OIL LLC Produced Fluid (in Barrels) 1,069.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 TRUE OIL LLC Produced Fluid (in Barrels) 118.00 Bbl INJECTION DISPOSAL WELL 34-059-24067

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1897255 Primary Facility 2010-07-07 Drilling/Alteration No Violations Noted
1897915 Primary Facility 2010-07-07 Routine/Complete Inspection No Violations Noted Marcellus well. Well being drilled at time of inspection. Inspection conducted with Rick Hoover.
1898822 Primary Facility 2010-07-15 Drilling/Alteration No Violations Noted
1900627 Primary Facility 2010-07-23 Drilling/Alteration No Violations Noted
1904348 Primary Facility 2010-08-10 Routine/Complete Inspection No Violations Noted Marcellus well. Well shut in on master gate at time of inspection.
1907844 Primary Facility 2010-08-19 Drilling/Alteration No Violations Noted
1964932 Primary Facility 2011-04-07 Routine/Complete Inspection No Violations Noted
1979939 Primary Facility 2011-06-10 Routine/Complete Inspection No Violations Noted
2229814 Primary Facility 2013-12-13 Routine/Complete Inspection No Violations Noted Marcellus. At time of inspection, well equipped for production. According to records, drilling occurred 7/3/2010-7/22/2010. Well tag present, legible.
2259729 Primary Facility 2014-04-02 Routine/Complete Inspection Violation(s) Noted Marcellus.Well equipped for production.Drilling occurred 7/3/10-7/22/10.WT present, legible.Two BTs on-site, appear sound.As noted in previous inspt, corrosion observed near top of tank closest to wellhead.Dept recommends Opr ensure structural integrity of BT is not compromised in order to prevent any potential pollution events from occurring.Pad rocked, stabilized.Shared AR stable.No accel E&S issues observed in relation to well site.Dept previously spoke to Opr rep via phone concerning recommended placements of site ID sign and Emergency Response Plan (inspection record 2229814).Dept still unable to locate proper signage and ERP.As per current regs, the Opr of an unconventional well shall display a reflective sign at AR entrance.Opr shall also prepare and implement an ERP and a copy of plan shall be available at well site during all phases of operation.Dept unable to locate well site restoration report for this site.Viols being issued under 25 PA CODE 78.55(4), 78.55(5), and 78.65(3).
2302464 Primary Facility 2014-09-05 Follow-up Inspection Outstanding Violations - No Viols Req'd FUI in response to violations issued under inspection record 2259729 (enf ID 309433).Two Bts on-site, appear sound. As noted previously, corrosion observed near top of tank closest to wellhead. Corrosion appears to have worsened since previous inspt. No active leaks and/or evidence of any prior release detected. Dept recommends Opr ensure structural integrity of BT is not compromised in order to prevent any potential pollution events from occurring.Pad rocked, stabilized. Shared access road stable. No accelerated erosion or sedimentation issues observed in relation to well site.Site ID sign installed, in compliance with Act 9 standards.
2327870 Primary Facility 2014-12-09 Follow-up Inspection Outstanding Violations - No Viols Req'd FUI in response to viols issued under record 2259729 (enf ID 309433)
2626376 Primary Facility 2017-08-08 Follow-up Inspection Outstanding Violations - Viols Req'd FUI conducted in response to violations issued under inspection record 2259729 (enf ID 309433).

Marcellus. At time of inspection, well drilled and appears equipped for production.

2637309 Primary Facility 2017-09-19 Administrative/File Review Outstanding Violations - Viols Req'd Admin inspection conducted in response to violations issued under inspection record 2259729 (enf ID 309433).

Operator electronically submitted well site restoration report to the Department. However, there is no well operator signature. This well site restoration report is being returned.

2638563 Primary Facility 2017-09-19 Compliance Evaluation No Violations Noted Admin inspection conducted in response to violations issued under inspection record 2259729 (enf ID 309433).

An administratively complete restoration report has been submitted by the operator. Therefore, violations issued for failure to submit a well site restoration report have been corrected.

2639373 Primary Facility 2017-09-25 Site Restoration No Violations Noted Inspection conducted in response to well site restoration report submitted by operator. At time of inspection, well drilled and appears equipped for production. Well site appears to be restored.
2826481 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted On 1/11/19 at 0943 hrs., I conducted a routine inspection of True Oil, LLC's Sweet M-1 well (API 063-36844) in West Mahoning Twp., Indiana Co. Snow cover prevented proper evaluation of site stabilization. The well pad appears to be restored and permanently stabilized. The well is properly labeled and equipped for production. A site ID sign and emergency response plan are posted. A well tag should be affixed to the well head. There are no violations being cited for this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2626376 794736 2017-08-08 2017-09-21 78.65(3)* Administrative This violation remains outstanding.
2637309 797532 2017-09-19 78.65(3)* Administrative This violation remains outstanding.

For data sources see[6]

References